Certificate holders

Subtype

DM Ecoline - R32 - 12

Certificate Holder
Dream Maker Technologie GmbH
Zimmerbachstr.37
74676 Niedernhall
Germany
Registration number
041-K043-02 / 01
Certification Body
BRE
Subtype title
DM Ecoline - R32 - 12
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,800 kg

Certification Date
02.02.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 09
Testing laboratory
TÜV SÜD Certification and Testing Co., Ltd. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

DM Ecoline Monoblock 12kw-O / DM Ecoline Monoblock 12kw-I
Configure model
Model name
DM Ecoline Monoblock 12kw-O / DM Ecoline Monoblock 12kw-I
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.67 kW

10.51 kW

El input

1.35 kW

3.83 kW

COP

4.93

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

46 dB(A)

Sound power level outdoor

52 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

132 %

Prated

8.79 kW

7.07 kW

SCOP

4.60

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.78 kW

6.26 kW

COP Tj = -7°C

3.25

1.79

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.91 kW

3.84 kW

COP Tj = +2°C

4.46

3.46

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.19 kW

4.05 kW

COP Tj = +7°C

6.16

4.84

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.02 kW

4.87 kW

COP Tj = 12°C

8.24

6.74

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.78 kW

6.26 kW

COP Tj = Tbiv

3.25

1.79

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.36 kW

5.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.78

1.78

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

56 °C

56 °C

Poff

17 W

9 W

PTO

25 W

25 W

PSB

17 W

9 W

PCK

33 W

39 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.43 kW

1.21 kW

Annual energy consumption Qhe

3944 kWh

4345 kWh