Certificate holders

Subtype

Tri-Thermal monobloc series 8 10 kW

Certificate Holder
GD TCL Intelligent Heating & Ventilating Equipment Co., Ltd.
No. 7 Yuanlin Road,
Guangdong
China
Registration number
041-K051-04
Certification Body
BRE Global Limited
Subtype title
Tri-Thermal monobloc series 8 10 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,500 kg

Certification Date
29.08.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 12
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

THMLd-8D/3HBp-A
Configure model
Model name
THMLd-8D/3HBp-A
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

7.40 kW

El input

1.60 kW

2.38 kW

COP

5.00

3.11

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

278 %

171 %

Prated

8.00 kW

8.00 kW

SCOP

7.02

4.35

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.70 kW

7.40 kW

COP Tj = +2°C

3.82

2.52

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.00 kW

4.90 kW

COP Tj = +7°C

6.12

3.60

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.60 kW

2.20 kW

COP Tj = 12°C

9.15

5.80

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.00 kW

4.90 kW

COP Tj = Tbiv

6.12

3.60

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.70 kW

7.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.82

2.52

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.60 kW

Annual energy consumption Qhe

1492 kWh

2347 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

115 %

Prated

7.00 kW

6.00 kW

SCOP

4.26

2.96

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.40 kW

3.80 kW

COP Tj = -7°C

3.59

2.48

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.60 kW

2.20 kW

COP Tj = +2°C

5.30

3.59

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.60 kW

1.40 kW

COP Tj = +7°C

5.98

4.08

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.90 kW

1.50 kW

COP Tj = 12°C

8.42

6.01

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.70 kW

4.80 kW

COP Tj = Tbiv

2.61

1.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.93

1.31

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.00 kW

2.80 kW

Annual energy consumption Qhe

4044 kWh

4891 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

4.80

COP Tj = -15°C (if TOL<-20°C)

2.61

1.87

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

136 %

Prated

8.00 kW

7.00 kW

SCOP

5.07

3.47

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.10 kW

5.80 kW

COP Tj = -7°C

3.12

2.20

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.70 kW

3.70 kW

COP Tj = +2°C

4.99

3.37

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.00 kW

2.40 kW

COP Tj = +7°C

6.81

4.57

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.70 kW

1.60 kW

COP Tj = 12°C

8.00

5.87

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.10 kW

5.80 kW

COP Tj = Tbiv

3.12

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.50 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.84

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

2.00 kW

Annual energy consumption Qhe

3276 kWh

3937 kWh

THML-8D/HBp-A
Configure model
Model name
THML-8D/HBp-A
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

7.40 kW

El input

1.60 kW

2.38 kW

COP

5.00

3.11

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

278 %

171 %

Prated

8.00 kW

8.00 kW

SCOP

7.02

4.35

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.70 kW

7.40 kW

COP Tj = +2°C

3.82

2.52

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.00 kW

4.90 kW

COP Tj = +7°C

6.12

3.60

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.60 kW

2.20 kW

COP Tj = 12°C

9.15

5.80

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.00 kW

4.90 kW

COP Tj = Tbiv

6.12

3.60

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.70 kW

7.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.82

2.52

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.60 kW

Annual energy consumption Qhe

1492 kWh

2347 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

115 %

Prated

7.00 kW

6.00 kW

SCOP

4.26

2.96

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.40 kW

3.80 kW

COP Tj = -7°C

3.59

2.48

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.60 kW

2.20 kW

COP Tj = +2°C

5.30

3.59

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.60 kW

1.40 kW

COP Tj = +7°C

5.98

4.08

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.90 kW

1.50 kW

COP Tj = 12°C

8.42

6.01

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.70 kW

4.80 kW

COP Tj = Tbiv

2.61

1.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.93

1.31

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.00 kW

2.80 kW

Annual energy consumption Qhe

4044 kWh

4891 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

4.80

COP Tj = -15°C (if TOL<-20°C)

2.61

1.87

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

136 %

Prated

8.00 kW

7.00 kW

SCOP

5.07

3.47

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.10 kW

5.80 kW

COP Tj = -7°C

3.12

2.20

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.70 kW

3.70 kW

COP Tj = +2°C

4.99

3.37

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.00 kW

2.40 kW

COP Tj = +7°C

6.81

4.57

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.70 kW

1.60 kW

COP Tj = 12°C

8.00

5.87

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.10 kW

5.80 kW

COP Tj = Tbiv

3.12

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.50 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.84

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

2.00 kW

Annual energy consumption Qhe

3276 kWh

3937 kWh

THMLd-10D/3HBp-A
Configure model
Model name
THMLd-10D/3HBp-A
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.50 kW

9.00 kW

El input

1.98 kW

3.00 kW

COP

4.80

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

268 %

179 %

Prated

9.00 kW

8.00 kW

SCOP

6.78

4.55

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.40 kW

7.60 kW

COP Tj = +2°C

3.67

2.27

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.50 kW

5.20 kW

COP Tj = +7°C

5.99

3.92

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.40 kW

2.50 kW

COP Tj = 12°C

8.73

6.17

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.50 kW

5.20 kW

COP Tj = Tbiv

5.99

3.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.40 kW

7.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.27

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.60 kW

0.40 kW

Annual energy consumption Qhe

1694 kWh

2353 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

170 %

116 %

Prated

8.00 kW

7.00 kW

SCOP

4.33

2.98

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.70 kW

4.10 kW

COP Tj = -7°C

3.50

2.53

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.00 kW

2.60 kW

COP Tj = +2°C

5.51

3.51

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.00 kW

1.70 kW

COP Tj = +7°C

6.63

4.52

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.90 kW

1.70 kW

COP Tj = 12°C

8.58

6.51

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.30 kW

5.50 kW

COP Tj = Tbiv

2.56

1.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.60 kW

2.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.99

1.24

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.40 kW

4.20 kW

Annual energy consumption Qhe

4417 kWh

5613 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.30

5.50

COP Tj = -15°C (if TOL<-20°C)

2.56

1.92

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

138 %

Prated

9.00 kW

8.00 kW

SCOP

5.05

3.51

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.00 kW

6.80 kW

COP Tj = -7°C

2.99

2.10

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.00 kW

4.20 kW

COP Tj = +2°C

4.97

3.44

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.10 kW

2.60 kW

COP Tj = +7°C

6.78

4.74

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.00 kW

1.80 kW

COP Tj = 12°C

9.10

6.22

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.00 kW

6.80 kW

COP Tj = Tbiv

2.99

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.30 kW

5.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.70 kW

2.80 kW

Annual energy consumption Qhe

3702 kWh

4537 kWh

THML-10D/HBp-A
Configure model
Model name
THML-10D/HBp-A
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.50 kW

9.00 kW

El input

1.98 kW

3.00 kW

COP

4.80

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

268 %

179 %

Prated

9.00 kW

8.00 kW

SCOP

6.78

4.55

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.40 kW

7.60 kW

COP Tj = +2°C

3.67

2.27

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.50 kW

5.20 kW

COP Tj = +7°C

5.99

3.92

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.40 kW

2.50 kW

COP Tj = 12°C

8.73

6.17

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.50 kW

5.20 kW

COP Tj = Tbiv

5.99

3.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.40 kW

7.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.27

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.60 kW

0.40 kW

Annual energy consumption Qhe

1694 kWh

2353 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

170 %

116 %

Prated

8.00 kW

7.00 kW

SCOP

4.33

2.98

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.70 kW

4.10 kW

COP Tj = -7°C

3.50

2.53

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.00 kW

2.60 kW

COP Tj = +2°C

5.51

3.51

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.00 kW

1.70 kW

COP Tj = +7°C

6.63

4.52

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.90 kW

1.70 kW

COP Tj = 12°C

8.58

6.51

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.30 kW

5.50 kW

COP Tj = Tbiv

2.56

1.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.60 kW

2.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.99

1.24

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.40 kW

4.20 kW

Annual energy consumption Qhe

4417 kWh

5613 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.30

5.50

COP Tj = -15°C (if TOL<-20°C)

2.56

1.92

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

138 %

Prated

9.00 kW

8.00 kW

SCOP

5.05

3.51

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.00 kW

6.80 kW

COP Tj = -7°C

2.99

2.10

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.00 kW

4.20 kW

COP Tj = +2°C

4.97

3.44

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.10 kW

2.60 kW

COP Tj = +7°C

6.78

4.74

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.00 kW

1.80 kW

COP Tj = 12°C

9.10

6.22

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.00 kW

6.80 kW

COP Tj = Tbiv

2.99

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.30 kW

5.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.70 kW

2.80 kW

Annual energy consumption Qhe

3702 kWh

4537 kWh