1,470 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.00 kW
8.00 kW
El input
1.54 kW
2.62 kW
COP
5.19
3.05
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
205 %
144 %
Prated
9.00 kW
8.70 kW
SCOP
5.21
3.68
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.00 kW
7.70 kW
COP Tj = -7°C
3.20
2.26
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
4.80 kW
4.70 kW
COP Tj = +2°C
5.19
3.56
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
3.90 kW
3.70 kW
COP Tj = +7°C
6.93
4.98
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
4.50 kW
4.40 kW
COP Tj = 12°C
8.77
6.86
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
8.00 kW
7.70 kW
COP Tj = Tbiv
3.20
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.90 kW
7.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.90
2.01
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
60 °C
60 °C
Poff
8 W
8 W
PTO
17 W
16 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.10 kW
1.30 kW
Annual energy consumption Qhe
3571 kWh
4880 kWh