2,200 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.5 kW
8.5 kW
El input
1.77 kW
3.01 kW
COP
4.8
2.82
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
227 %
156 %
Prated
8.5 kW
8.5 kW
SCOP
5.76
3.98
Tbiv
2 °C
2 °C
TOL
-20 °C
-20 °C
Pdh Tj = +2°C
8.5 kW
8.5 kW
COP Tj = +2°C
3.51
1.88
Cdh Tj = +2 °C
0.99
1
Pdh Tj = +7°C
5.5 kW
5.5 kW
COP Tj = +7°C
5
3.28
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.6 kW
3.4 kW
COP Tj = 12°C
7.77
5.76
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
8.5 kW
8.5 kW
COP Tj = Tbiv
3.51
1.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.5 kW
8.5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.51
1.88
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1972 kWh
2852 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
193 %
139 %
Prated
8.5 kW
8.5 kW
SCOP
4.89
3.54
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.5 kW
7.5 kW
COP Tj = -7°C
3.1
2.07
Cdh Tj = -7 °C
0.99
1
Pdh Tj = +2°C
4.6 kW
4.6 kW
COP Tj = +2°C
4.71
3.42
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
3.2 kW
3.7 kW
COP Tj = +7°C
6.81
5
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
3.2 kW
3.4 kW
COP Tj = 12°C
9.14
7.08
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
7.5 kW
7.5 kW
COP Tj = Tbiv
3.1
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.18 kW
7.18 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.8
2.01
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.32 kW
1.32 kW
Annual energy consumption Qhe
3592 kWh
4958 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
135 %
COP
3.24
Heating up time
03:42 h:min
Standby power input
39 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
120 %
COP
2.89
Heating up time
04:02 h:min
Standby power input
42 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.5 kW
8.5 kW
El input
1.77 kW
3.01 kW
COP
4.8
2.82
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
227 %
156 %
Prated
8.5 kW
8.5 kW
SCOP
5.76
3.98
Tbiv
2 °C
2 °C
TOL
-20 °C
-20 °C
Pdh Tj = +2°C
8.5 kW
8.5 kW
COP Tj = +2°C
3.51
1.88
Cdh Tj = +2 °C
0.99
1
Pdh Tj = +7°C
5.5 kW
5.5 kW
COP Tj = +7°C
5
3.28
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.6 kW
3.4 kW
COP Tj = 12°C
7.77
5.76
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
8.5 kW
8.5 kW
COP Tj = Tbiv
3.51
1.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.5 kW
8.5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.51
1.88
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1972 kWh
2852 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
193 %
139 %
Prated
8.5 kW
8.5 kW
SCOP
4.89
3.54
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.5 kW
7.5 kW
COP Tj = -7°C
3.1
2.07
Cdh Tj = -7 °C
0.99
1
Pdh Tj = +2°C
4.6 kW
4.6 kW
COP Tj = +2°C
4.71
3.42
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
3.2 kW
3.7 kW
COP Tj = +7°C
6.81
5
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
3.2 kW
3.4 kW
COP Tj = 12°C
9.14
7.08
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
7.5 kW
7.5 kW
COP Tj = Tbiv
3.1
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.18 kW
7.18 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.8
2.01
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.32 kW
1.32 kW
Annual energy consumption Qhe
3592 kWh
4958 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
135 %
COP
3.24
Heating up time
03:42 h:min
Standby power input
39 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
120 %
COP
2.89
Heating up time
04:02 h:min
Standby power input
42 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.5 kW
8.5 kW
El input
1.77 kW
3.01 kW
COP
4.8
2.82
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
234 %
159 %
Prated
8.5 kW
8.5 kW
SCOP
5.92
4.05
Tbiv
2 °C
2 °C
TOL
-20 °C
-20 °C
Pdh Tj = +2°C
8.5 kW
8.5 kW
COP Tj = +2°C
3.51
1.88
Cdh Tj = +2 °C
0.99
1
Pdh Tj = +7°C
5.5 kW
5.5 kW
COP Tj = +7°C
4.92
3.24
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.6 kW
3.4 kW
COP Tj = 12°C
7.77
5.76
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
8.5 kW
8.5 kW
COP Tj = Tbiv
3.51
1.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.5 kW
8.5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.51
1.88
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1920 kWh
2802 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
197 %
141 %
Prated
8.5 kW
8.5 kW
SCOP
5
3.6
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.5 kW
7.5 kW
COP Tj = -7°C
3.1
2.07
Cdh Tj = -7 °C
0.99
1
Pdh Tj = +2°C
4.6 kW
4.6 kW
COP Tj = +2°C
4.77
3.45
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
3.2 kW
3.7 kW
COP Tj = +7°C
6.81
5
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
3.2 kW
3.4 kW
COP Tj = 12°C
9.14
7.08
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
7.5 kW
7.5 kW
COP Tj = Tbiv
3.1
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.18 kW
7.18 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.8
2.01
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.32 kW
1.32 kW
Annual energy consumption Qhe
3515 kWh
4881 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
135 %
COP
3.24
Heating up time
03:42 h:min
Standby power input
39 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
120 %
COP
2.89
Heating up time
04:02 h:min
Standby power input
42 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.5 kW
8.5 kW
El input
1.77 kW
3.01 kW
COP
4.8
2.82
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
224 %
155 %
Prated
8.5 kW
8.5 kW
SCOP
5.69
3.94
Tbiv
2 °C
2 °C
TOL
-20 °C
-20 °C
Pdh Tj = +2°C
8.5 kW
8.5 kW
COP Tj = +2°C
3.51
1.88
Cdh Tj = +2 °C
0.99
1
Pdh Tj = +7°C
5.5 kW
5.5 kW
COP Tj = +7°C
5.1
3.31
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.6 kW
3.4 kW
COP Tj = 12°C
7.78
5.76
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
8.5 kW
8.5 kW
COP Tj = Tbiv
3.51
1.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.5 kW
8.5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.51
1.88
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1997 kWh
2882 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
138 %
Prated
8.5 kW
8.5 kW
SCOP
4.84
3.52
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.5 kW
7.5 kW
COP Tj = -7°C
3.1
2.07
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
4.6 kW
4.6 kW
COP Tj = +2°C
4.69
3.42
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
3.2 kW
3.7 kW
COP Tj = +7°C
6.82
5
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
3.2 kW
3.4 kW
COP Tj = 12°C
9.14
7.08
Cdh Tj = +12 °C
0.96
0.95
Pdh Tj = Tbiv
7.5 kW
7.5 kW
COP Tj = Tbiv
3.1
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.18 kW
7.18 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.8
2.01
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.32 kW
1.32 kW
Annual energy consumption Qhe
3632 kWh
4994 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
135 %
COP
3.24
Heating up time
03:42 h:min
Standby power input
39 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
120 %
COP
2.89
Heating up time
04:02 h:min
Standby power input
42 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.5 kW
8.5 kW
El input
1.77 kW
3.01 kW
COP
4.8
2.82
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
224 %
155 %
Prated
8.5 kW
8.5 kW
SCOP
5.69
3.94
Tbiv
2 °C
2 °C
TOL
-20 °C
-20 °C
Pdh Tj = +2°C
8.5 kW
8.5 kW
COP Tj = +2°C
3.51
1.88
Cdh Tj = +2 °C
0.99
1
Pdh Tj = +7°C
5.5 kW
5.5 kW
COP Tj = +7°C
5.1
3.22
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.6 kW
3.4 kW
COP Tj = 12°C
7.78
5.76
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
8.5 kW
8.5 kW
COP Tj = Tbiv
3.51
1.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.5 kW
8.5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.51
1.88
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1997 kWh
2882 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
138 %
Prated
8.5 kW
8.5 kW
SCOP
4.84
3.52
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.5 kW
7.5 kW
COP Tj = -7°C
3.1
2.07
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
4.6 kW
4.6 kW
COP Tj = +2°C
4.69
3.42
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
3.2 kW
3.7 kW
COP Tj = +7°C
6.82
5
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
3.2 kW
3.4 kW
COP Tj = 12°C
9.14
7.08
Cdh Tj = +12 °C
0.96
0.95
Pdh Tj = Tbiv
7.5 kW
7.5 kW
COP Tj = Tbiv
3.1
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.18 kW
7.18 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.8
2.01
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.32 kW
1.32 kW
Annual energy consumption Qhe
3632 kWh
4994 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
135 %
COP
3.24
Heating up time
03:42 h:min
Standby power input
39 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
120 %
COP
2.89
Heating up time
04:02 h:min
Standby power input
42 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.5 kW
8.5 kW
El input
1.77 kW
3.01 kW
COP
4.8
2.82
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
234 %
159 %
Prated
8.5 kW
8.5 kW
SCOP
5.91
4.05
Tbiv
2 °C
2 °C
TOL
-20 °C
-20 °C
Pdh Tj = +2°C
8.5 kW
8.5 kW
COP Tj = +2°C
3.51
1.88
Cdh Tj = +2 °C
0.99
1
Pdh Tj = +7°C
5.5 kW
5.5 kW
COP Tj = +7°C
4.98
3.26
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.6 kW
3.4 kW
COP Tj = 12°C
7.78
5.76
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
8.5 kW
8.5 kW
COP Tj = Tbiv
3.51
1.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.5 kW
8.5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.51
1.88
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1920 kWh
2805 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
197 %
141 %
Prated
8.5 kW
8.5 kW
SCOP
5
3.6
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.5 kW
7.5 kW
COP Tj = -7°C
3.1
2.07
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
4.6 kW
4.6 kW
COP Tj = +2°C
4.79
3.46
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
3.2 kW
3.7 kW
COP Tj = +7°C
6.81
5
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
3.2 kW
3.4 kW
COP Tj = 12°C
9.14
7.08
Cdh Tj = +12 °C
0.96
0.95
Pdh Tj = Tbiv
7.5 kW
7.5 kW
COP Tj = Tbiv
3.1
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.18 kW
7.18 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.8
2.01
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.32 kW
1.32 kW
Annual energy consumption Qhe
3514 kWh
4884 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
135 %
COP
3.24
Heating up time
03:42 h:min
Standby power input
39 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
120 %
COP
2.89
Heating up time
04:02 h:min
Standby power input
42 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.5 kW
6.5 kW
El input
1.33 kW
2.24 kW
COP
4.9
2.9
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
229 %
157 %
Prated
8.5 kW
8.5 kW
SCOP
5.81
4
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
8.5 kW
8.5 kW
COP Tj = +2°C
2.95
1.98
Cdh Tj = +2 °C
0.995
0.997
Pdh Tj = +7°C
5.5 kW
5.46 kW
COP Tj = +7°C
5.09
3.33
Cdh Tj = +7 °C
0.986
0.991
Pdh Tj = 12°C
3.38 kW
3.78 kW
COP Tj = 12°C
8.02
5.69
Cdh Tj = +12 °C
0.964
0.977
Pdh Tj = Tbiv
8.5 kW
8.5 kW
COP Tj = Tbiv
2.95
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.5 kW
8.5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.95
1.98
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.997
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1956 kWh
2839 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
192 %
140 %
Prated
8.5 kW
8.5 kW
SCOP
4.86
3.56
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.52 kW
7.52 kW
COP Tj = -7°C
3.3
2.18
Cdh Tj = -7 °C
0.993
0.996
Pdh Tj = +2°C
4.64 kW
4.57 kW
COP Tj = +2°C
4.9
3.5
Cdh Tj = +2 °C
0.984
0.989
Pdh Tj = +7°C
3.18 kW
3.78 kW
COP Tj = +7°C
5.84
4.7
Cdh Tj = +7 °C
0.972
0.981
Pdh Tj = 12°C
3.2 kW
3.78 kW
COP Tj = 12°C
8.79
6.98
Cdh Tj = +12 °C
0.959
0.972
Pdh Tj = Tbiv
7.52 kW
7.52 kW
COP Tj = Tbiv
3.3
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.2 kW
7.2 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.05
2
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.996
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.3 kW
1.3 kW
Annual energy consumption Qhe
3611 kWh
4927 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
134 %
COP
3.25
Heating up time
3:16 h:min
Standby power input
43.7 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
113 %
COP
2.76
Heating up time
3:57 h:min
Standby power input
46.7 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.5 kW
6.5 kW
El input
1.33 kW
2.24 kW
COP
4.9
2.9
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
237 %
161 %
Prated
8.5 kW
8.5 kW
SCOP
6.01
4.1
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
8.5 kW
8.5 kW
COP Tj = +2°C
2.95
1.98
Cdh Tj = +2 °C
0.995
0.997
Pdh Tj = +7°C
5.5 kW
5.46 kW
COP Tj = +7°C
5.09
3.33
Cdh Tj = +7 °C
0.986
0.991
Pdh Tj = 12°C
3.38 kW
3.78 kW
COP Tj = 12°C
8.02
5.69
Cdh Tj = +12 °C
0.964
0.977
Pdh Tj = Tbiv
8.5 kW
8.5 kW
COP Tj = Tbiv
2.95
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.5 kW
8.5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.95
1.98
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.997
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1890 kWh
2772 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
141 %
Prated
8.5 kW
8.5 kW
SCOP
4.94
3.6
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.52 kW
7.52 kW
COP Tj = -7°C
3.3
2.18
Cdh Tj = -7 °C
0.993
0.996
Pdh Tj = +2°C
4.64 kW
4.57 kW
COP Tj = +2°C
4.9
3.5
Cdh Tj = +2 °C
0.984
0.989
Pdh Tj = +7°C
3.18 kW
3.78 kW
COP Tj = +7°C
5.84
4.7
Cdh Tj = +7 °C
0.972
0.981
Pdh Tj = 12°C
3.2 kW
3.78 kW
COP Tj = 12°C
8.79
6.98
Cdh Tj = +12 °C
0.959
0.972
Pdh Tj = Tbiv
7.52 kW
7.52 kW
COP Tj = Tbiv
3.3
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.2 kW
7.2 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.05
2
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.996
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.3 kW
1.3 kW
Annual energy consumption Qhe
3556 kWh
4872 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
134 %
COP
3.25
Heating up time
3:16 h:min
Standby power input
43.7 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
113 %
COP
2.76
Heating up time
3:57 h:min
Standby power input
46.7 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.5 kW
6.5 kW
El input
1.33 kW
2.24 kW
COP
4.9
2.9
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
224 %
155 %
Prated
8.5 kW
8.5 kW
SCOP
5.69
3.94
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
8.5 kW
8.5 kW
COP Tj = +2°C
2.95
1.98
Cdh Tj = +2 °C
0.992
0.995
Pdh Tj = +7°C
5.5 kW
5.46 kW
COP Tj = +7°C
5.09
3.33
Cdh Tj = +7 °C
0.98
0.987
Pdh Tj = 12°C
3.38 kW
3.78 kW
COP Tj = 12°C
8.02
5.69
Cdh Tj = +12 °C
0.948
0.967
Pdh Tj = Tbiv
8.5 kW
8.5 kW
COP Tj = Tbiv
2.95
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.5 kW
8.5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.95
1.98
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.995
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1997 kWh
2881 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
139 %
Prated
8.5 kW
8.5 kW
SCOP
4.82
3.54
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.52 kW
7.52 kW
COP Tj = -7°C
3.3
2.18
Cdh Tj = -7 °C
0.99
0.994
Pdh Tj = +2°C
4.64 kW
4.57 kW
COP Tj = +2°C
4.9
3.5
Cdh Tj = +2 °C
0.977
0.983
Pdh Tj = +7°C
3.18 kW
3.78 kW
COP Tj = +7°C
5.84
4.7
Cdh Tj = +7 °C
0.96
0.973
Pdh Tj = 12°C
3.2 kW
3.78 kW
COP Tj = 12°C
8.79
6.98
Cdh Tj = +12 °C
0.94
0.959
Pdh Tj = Tbiv
7.52 kW
7.52 kW
COP Tj = Tbiv
3.3
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.2 kW
7.2 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.05
2
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.991
0.994
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.3 kW
1.3 kW
Annual energy consumption Qhe
3644 kWh
4964 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
134 %
COP
3.25
Heating up time
3:16 h:min
Standby power input
43.7 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
113 %
COP
2.76
Heating up time
3:57 h:min
Standby power input
46.7 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.5 kW
6.5 kW
El input
1.33 kW
2.24 kW
COP
4.9
2.9
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
236 %
160 %
Prated
8.5 kW
8.5 kW
SCOP
5.98
4.08
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
8.5 kW
8.5 kW
COP Tj = +2°C
2.95
1.98
Cdh Tj = +2 °C
0.992
0.995
Pdh Tj = +7°C
5.5 kW
5.46 kW
COP Tj = +7°C
5.09
3.33
Cdh Tj = +7 °C
0.98
0.987
Pdh Tj = 12°C
3.38 kW
3.78 kW
COP Tj = 12°C
8.02
5.69
Cdh Tj = +12 °C
0.948
0.967
Pdh Tj = Tbiv
8.5 kW
8.5 kW
COP Tj = Tbiv
2.95
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.5 kW
8.5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.95
1.98
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.995
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1900 kWh
2784 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
194 %
141 %
Prated
8.5 kW
8.5 kW
SCOP
4.93
3.6
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.52 kW
7.52 kW
COP Tj = -7°C
3.3
2.18
Cdh Tj = -7 °C
0.99
0.994
Pdh Tj = +2°C
4.64 kW
4.57 kW
COP Tj = +2°C
4.9
3.5
Cdh Tj = +2 °C
0.977
0.983
Pdh Tj = +7°C
3.18 kW
3.78 kW
COP Tj = +7°C
5.84
4.7
Cdh Tj = +7 °C
0.96
0.973
Pdh Tj = 12°C
3.2 kW
3.78 kW
COP Tj = 12°C
8.79
6.98
Cdh Tj = +12 °C
0.94
0.959
Pdh Tj = Tbiv
7.52 kW
7.52 kW
COP Tj = Tbiv
3.3
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.2 kW
7.2 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.05
2
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.991
0.994
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.3 kW
1.3 kW
Annual energy consumption Qhe
3563 kWh
4883 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
134 %
COP
3.25
Heating up time
3:16 h:min
Standby power input
43.7 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
113 %
COP
2.76
Heating up time
3:57 h:min
Standby power input
46.7 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l