3,300 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14 kW
14 kW
El input
3.14 kW
5.24 kW
COP
4.46
2.67
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
227 %
160 %
Prated
14 kW
14 kW
SCOP
5.75
4.07
Tbiv
2 °C
2 °C
TOL
-28 °C
-28 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.15
1.94
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.1
3.25
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.5 kW
5.2 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.15
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.15
1.94
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3252 kWh
4593 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
132 %
Prated
14 kW
14 kW
SCOP
4.47
3.37
Tbiv
-7 °C
-7 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
12.4 kW
12.4 kW
COP Tj = -7°C
2.55
1.98
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
7.5 kW
7.5 kW
COP Tj = +2°C
4.4
3.25
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.9 kW
5.1 kW
COP Tj = +7°C
6.28
4.64
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
5.7 kW
5.2 kW
COP Tj = 12°C
7.43
6.24
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.4 kW
12.4 kW
COP Tj = Tbiv
2.55
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.4
1.75
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6470 kWh
8589 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
152 %
COP
3.58
Heating up time
01:34 h:min
Standby power input
35 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
130 %
COP
3.07
Heating up time
01:46 h:min
Standby power input
38 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14 kW
14 kW
El input
3.14 kW
5.24 kW
COP
4.46
2.67
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
227 %
160 %
Prated
14 kW
14 kW
SCOP
5.75
4.07
Tbiv
2 °C
2 °C
TOL
-28 °C
-28 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.15
1.94
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.1
3.25
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.5 kW
5.2 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.15
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.15
1.94
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3252 kWh
4593 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
132 %
Prated
14 kW
14 kW
SCOP
4.47
3.37
Tbiv
-7 °C
-7 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
12.4 kW
12.4 kW
COP Tj = -7°C
2.55
1.98
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
7.5 kW
7.5 kW
COP Tj = +2°C
4.4
3.25
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.9 kW
5.1 kW
COP Tj = +7°C
6.28
4.64
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
5.7 kW
5.2 kW
COP Tj = 12°C
7.43
6.24
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.4 kW
12.4 kW
COP Tj = Tbiv
2.55
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.4
1.75
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6470 kWh
8589 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
152 %
COP
3.58
Heating up time
01:34 h:min
Standby power input
35 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
130 %
COP
3.07
Heating up time
01:46 h:min
Standby power input
38 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14 kW
14 kW
El input
3.14 kW
5.24 kW
COP
4.46
2.67
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
227 %
160 %
Prated
14 kW
14 kW
SCOP
5.75
4.07
Tbiv
2 °C
2 °C
TOL
-28 °C
-28 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.15
1.94
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.1
3.25
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.5 kW
5.2 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.15
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.15
1.94
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3252 kWh
4593 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
132 %
Prated
14 kW
14 kW
SCOP
4.47
3.37
Tbiv
-7 °C
-7 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
12.4 kW
12.4 kW
COP Tj = -7°C
2.55
1.98
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
7.5 kW
7.5 kW
COP Tj = +2°C
4.4
3.25
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.9 kW
5.1 kW
COP Tj = +7°C
6.28
4.64
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
5.7 kW
5.2 kW
COP Tj = 12°C
7.43
6.24
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.4 kW
12.4 kW
COP Tj = Tbiv
2.55
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.4
1.75
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6470 kWh
8589 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14 kW
14 kW
El input
3.14 kW
5.24 kW
COP
4.46
2.67
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
227 %
160 %
Prated
14 kW
14 kW
SCOP
5.75
4.07
Tbiv
2 °C
2 °C
TOL
-28 °C
-28 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.15
1.94
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.1
3.25
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.5 kW
5.2 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.15
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.15
1.94
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3252 kWh
4593 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
132 %
Prated
14 kW
14 kW
SCOP
4.47
3.37
Tbiv
-7 °C
-7 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
12.4 kW
12.4 kW
COP Tj = -7°C
2.55
1.98
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
7.5 kW
7.5 kW
COP Tj = +2°C
4.4
3.25
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.9 kW
5.1 kW
COP Tj = +7°C
6.28
4.64
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
5.7 kW
5.2 kW
COP Tj = 12°C
7.43
6.24
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.4 kW
12.4 kW
COP Tj = Tbiv
2.55
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.4
1.75
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6470 kWh
8589 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14 kW
14 kW
El input
3.14 kW
5.24 kW
COP
4.46
2.67
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
232 %
162 %
Prated
14 kW
14 kW
SCOP
5.87
4.13
Tbiv
2 °C
2 °C
TOL
-28 °C
-28 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.15
1.94
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.1
3.25
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.5 kW
5.2 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.15
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.15
1.94
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3186 kWh
4527 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
133 %
Prated
14 kW
14 kW
SCOP
4.51
3.39
Tbiv
-7 °C
-7 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
12.4 kW
12.4 kW
COP Tj = -7°C
2.55
1.98
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
7.5 kW
7.5 kW
COP Tj = +2°C
4.4
3.25
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.9 kW
5.1 kW
COP Tj = +7°C
6.28
4.64
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
5.7 kW
5.2 kW
COP Tj = 12°C
7.43
6.24
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.4 kW
12.4 kW
COP Tj = Tbiv
2.55
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.4
1.75
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6407 kWh
8534 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
152 %
COP
3.58
Heating up time
01:34 h:min
Standby power input
35 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
130 %
COP
3.07
Heating up time
01:46 h:min
Standby power input
38 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14 kW
14 kW
El input
3.14 kW
5.24 kW
COP
4.46
2.67
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
232 %
162 %
Prated
14 kW
14 kW
SCOP
5.87
4.13
Tbiv
2 °C
2 °C
TOL
-28 °C
-28 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.15
1.94
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.1
3.25
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.5 kW
5.2 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.15
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.15
1.94
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3186 kWh
4527 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
133 %
Prated
14 kW
14 kW
SCOP
4.51
3.39
Tbiv
-7 °C
-7 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
12.4 kW
12.4 kW
COP Tj = -7°C
2.55
1.98
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
7.5 kW
7.5 kW
COP Tj = +2°C
4.4
3.25
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.9 kW
5.1 kW
COP Tj = +7°C
6.28
4.64
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
5.7 kW
5.2 kW
COP Tj = 12°C
7.43
6.24
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.4 kW
12.4 kW
COP Tj = Tbiv
2.55
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.4
1.75
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6407 kWh
8534 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
152 %
COP
3.58
Heating up time
01:34 h:min
Standby power input
35 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
130 %
COP
3.07
Heating up time
01:46 h:min
Standby power input
38 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14 kW
14 kW
El input
3.14 kW
5.24 kW
COP
4.46
2.67
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
232 %
162 %
Prated
14 kW
14 kW
SCOP
5.87
4.13
Tbiv
2 °C
2 °C
TOL
-28 °C
-28 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.15
1.94
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.1
3.25
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.5 kW
5.2 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.15
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.15
1.94
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3186 kWh
4527 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
133 %
Prated
14 kW
14 kW
SCOP
4.51
3.39
Tbiv
-7 °C
-7 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
12.4 kW
12.4 kW
COP Tj = -7°C
2.55
1.98
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
7.5 kW
7.5 kW
COP Tj = +2°C
4.4
3.25
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.9 kW
5.1 kW
COP Tj = +7°C
6.28
4.64
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
5.7 kW
5.2 kW
COP Tj = 12°C
7.43
6.24
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.4 kW
12.4 kW
COP Tj = Tbiv
2.55
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.4
1.75
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6407 kWh
8534 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14 kW
14 kW
El input
3.14 kW
5.24 kW
COP
4.46
2.67
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
225 %
159 %
Prated
14 kW
14 kW
SCOP
5.69
4.04
Tbiv
2 °C
2 °C
TOL
-28 °C
-28 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.15
1.94
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.12
3.26
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.5 kW
5.2 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.15
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.15
1.94
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3288 kWh
4628 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
131 %
Prated
14 kW
14 kW
SCOP
4.46
3.36
Tbiv
-7 °C
-7 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
12.4 kW
12.4 kW
COP Tj = -7°C
2.55
1.98
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
7.5 kW
7.5 kW
COP Tj = +2°C
4.42
3.26
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.9 kW
5.1 kW
COP Tj = +7°C
6.26
4.64
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
5.7 kW
5.2 kW
COP Tj = 12°C
7.43
6.24
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.4 kW
12.4 kW
COP Tj = Tbiv
2.55
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.4
1.75
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6492 kWh
8608 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
152 %
COP
3.58
Heating up time
01:34 h:min
Standby power input
35 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
130 %
COP
3.07
Heating up time
01:46 h:min
Standby power input
38 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14 kW
14 kW
El input
3.14 kW
5.24 kW
COP
4.46
2.67
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
225 %
159 %
Prated
14 kW
14 kW
SCOP
5.69
4.04
Tbiv
2 °C
2 °C
TOL
-28 °C
-28 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.15
1.94
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.12
3.26
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.5 kW
5.2 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.15
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.15
1.94
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3288 kWh
4628 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
131 %
Prated
14 kW
14 kW
SCOP
4.46
3.36
Tbiv
-7 °C
-7 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
12.4 kW
12.4 kW
COP Tj = -7°C
2.55
1.98
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
7.5 kW
7.5 kW
COP Tj = +2°C
4.42
3.26
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.9 kW
5.1 kW
COP Tj = +7°C
6.26
4.64
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
5.7 kW
5.2 kW
COP Tj = 12°C
7.43
6.24
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.4 kW
12.4 kW
COP Tj = Tbiv
2.55
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.4
1.75
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6492 kWh
8608 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
152 %
COP
3.58
Heating up time
01:34 h:min
Standby power input
35 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
130 %
COP
3.07
Heating up time
01:46 h:min
Standby power input
38 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14 kW
14 kW
El input
3.14 kW
5.24 kW
COP
4.46
2.67
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
225 %
159 %
Prated
14 kW
14 kW
SCOP
5.69
4.04
Tbiv
2 °C
2 °C
TOL
-28 °C
-28 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.15
1.94
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.12
3.26
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.5 kW
5.2 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.15
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.15
1.94
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3288 kWh
4628 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
131 %
Prated
14 kW
14 kW
SCOP
4.46
3.36
Tbiv
-7 °C
-7 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
12.4 kW
12.4 kW
COP Tj = -7°C
2.55
1.98
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
7.5 kW
7.5 kW
COP Tj = +2°C
4.42
3.26
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.9 kW
5.1 kW
COP Tj = +7°C
6.26
4.64
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
5.7 kW
5.2 kW
COP Tj = 12°C
7.43
6.24
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.4 kW
12.4 kW
COP Tj = Tbiv
2.55
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.4
1.75
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6492 kWh
8608 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14 kW
14 kW
El input
3.14 kW
5.24 kW
COP
4.46
2.67
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
225 %
159 %
Prated
14 kW
14 kW
SCOP
5.69
4.04
Tbiv
2 °C
2 °C
TOL
-28 °C
-28 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.15
1.94
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.12
3.26
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.5 kW
5.2 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.15
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.15
1.94
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3288 kWh
4628 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
131 %
Prated
14 kW
14 kW
SCOP
4.46
3.36
Tbiv
-7 °C
-7 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
12.4 kW
12.4 kW
COP Tj = -7°C
2.55
1.98
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
7.5 kW
7.5 kW
COP Tj = +2°C
4.42
3.26
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.9 kW
5.1 kW
COP Tj = +7°C
6.26
4.64
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
5.7 kW
5.2 kW
COP Tj = 12°C
7.43
6.24
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.4 kW
12.4 kW
COP Tj = Tbiv
2.55
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.4
1.75
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6492 kWh
8608 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14 kW
14 kW
El input
3.14 kW
5.24 kW
COP
4.46
2.67
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
231 %
162 %
Prated
14 kW
14 kW
SCOP
5.86
4.13
Tbiv
2 °C
2 °C
TOL
-28 °C
-28 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.15
1.94
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.12
3.26
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.5 kW
5.2 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.15
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.15
1.94
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3191 kWh
4531 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
133 %
Prated
14 kW
14 kW
SCOP
4.51
3.39
Tbiv
-7 °C
-7 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
12.4 kW
12.4 kW
COP Tj = -7°C
2.55
1.98
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
7.5 kW
7.5 kW
COP Tj = +2°C
4.42
3.26
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.9 kW
5.1 kW
COP Tj = +7°C
6.26
4.64
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
5.7 kW
5.2 kW
COP Tj = 12°C
7.43
6.24
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.4 kW
12.4 kW
COP Tj = Tbiv
2.55
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.4
1.75
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6412 kWh
8528 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
152 %
COP
3.58
Heating up time
01:34 h:min
Standby power input
35 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
130 %
COP
3.07
Heating up time
01:46 h:min
Standby power input
38 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14 kW
14 kW
El input
3.14 kW
5.24 kW
COP
4.46
2.67
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
231 %
162 %
Prated
14 kW
14 kW
SCOP
5.86
4.13
Tbiv
2 °C
2 °C
TOL
-28 °C
-28 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.15
1.94
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.12
3.26
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.5 kW
5.2 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.15
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.15
1.94
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3191 kWh
4531 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
133 %
Prated
14 kW
14 kW
SCOP
4.51
3.39
Tbiv
-7 °C
-7 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
12.4 kW
12.4 kW
COP Tj = -7°C
2.55
1.98
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
7.5 kW
7.5 kW
COP Tj = +2°C
4.42
3.26
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.9 kW
5.1 kW
COP Tj = +7°C
6.26
4.64
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
5.7 kW
5.2 kW
COP Tj = 12°C
7.43
6.24
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.4 kW
12.4 kW
COP Tj = Tbiv
2.55
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.4
1.75
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6412 kWh
8528 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
152 %
COP
3.58
Heating up time
01:34 h:min
Standby power input
35 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
130 %
COP
3.07
Heating up time
01:46 h:min
Standby power input
38 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14 kW
14 kW
El input
3.14 kW
5.24 kW
COP
4.46
2.67
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
231 %
162 %
Prated
14 kW
14 kW
SCOP
5.86
4.13
Tbiv
2 °C
2 °C
TOL
-28 °C
-28 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.15
1.94
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.12
3.26
Cdh Tj = +7 °C
0.99
1
Pdh Tj = 12°C
5.5 kW
5.2 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.15
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.15
1.94
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3191 kWh
4531 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
133 %
Prated
14 kW
14 kW
SCOP
4.51
3.39
Tbiv
-7 °C
-7 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
12.4 kW
12.4 kW
COP Tj = -7°C
2.55
1.98
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
7.5 kW
7.5 kW
COP Tj = +2°C
4.42
3.26
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.9 kW
5.1 kW
COP Tj = +7°C
6.26
4.64
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
5.7 kW
5.2 kW
COP Tj = 12°C
7.43
6.24
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.4 kW
12.4 kW
COP Tj = Tbiv
2.55
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.4
1.75
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6412 kWh
8528 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12 kW
12 kW
El input
2.67 kW
4.29 kW
COP
4.5
2.8
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
228 %
160 %
Prated
14 kW
14 kW
SCOP
5.77
4.08
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.07
1.83
Cdh Tj = +2 °C
0.997
0.998
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.15
3.3
Cdh Tj = +7 °C
0.991
0.995
Pdh Tj = 12°C
5.47 kW
5.15 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.98
0.983
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.07
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.07
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3244 kWh
4584 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
132 %
Prated
14 kW
14 kW
SCOP
4.48
3.37
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.38 kW
12.38 kW
COP Tj = -7°C
2.74
1.7
Cdh Tj = -7 °C
0.997
0.998
Pdh Tj = +2°C
7.56 kW
7.56 kW
COP Tj = +2°C
4.5
3.45
Cdh Tj = +2 °C
0.991
0.993
Pdh Tj = +7°C
4.92 kW
4.92 kW
COP Tj = +7°C
5.72
4.65
Cdh Tj = +7 °C
0.983
0.986
Pdh Tj = 12°C
5.55 kW
5.25 kW
COP Tj = 12°C
7.37
6.29
Cdh Tj = +12 °C
0.98
0.982
Pdh Tj = Tbiv
12.38 kW
12.38 kW
COP Tj = Tbiv
2.74
1.7
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.44
1.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6452 kWh
8579 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
161 %
COP
3.78
Heating up time
1:39 h:min
Standby power input
38.9 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
133 %
COP
3.17
Heating up time
1:48 h:min
Standby power input
41.7 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12 kW
12 kW
El input
2.67 kW
4.29 kW
COP
4.5
2.8
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
228 %
160 %
Prated
14 kW
14 kW
SCOP
5.77
4.08
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.07
1.83
Cdh Tj = +2 °C
0.997
0.998
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.15
3.3
Cdh Tj = +7 °C
0.991
0.995
Pdh Tj = 12°C
5.47 kW
5.15 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.98
0.983
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.07
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.07
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3244 kWh
4584 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
132 %
Prated
14 kW
14 kW
SCOP
4.48
3.37
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.38 kW
12.38 kW
COP Tj = -7°C
2.74
1.7
Cdh Tj = -7 °C
0.997
0.998
Pdh Tj = +2°C
7.56 kW
7.56 kW
COP Tj = +2°C
4.5
3.45
Cdh Tj = +2 °C
0.991
0.993
Pdh Tj = +7°C
4.92 kW
4.92 kW
COP Tj = +7°C
5.72
4.65
Cdh Tj = +7 °C
0.983
0.986
Pdh Tj = 12°C
5.55 kW
5.25 kW
COP Tj = 12°C
7.37
6.29
Cdh Tj = +12 °C
0.98
0.982
Pdh Tj = Tbiv
12.38 kW
12.38 kW
COP Tj = Tbiv
2.74
1.7
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.44
1.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6452 kWh
8579 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
161 %
COP
3.78
Heating up time
1:39 h:min
Standby power input
38.9 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
133 %
COP
3.17
Heating up time
1:48 h:min
Standby power input
41.7 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12 kW
12 kW
El input
2.67 kW
4.29 kW
COP
4.5
2.8
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
232 %
163 %
Prated
14 kW
14 kW
SCOP
5.89
4.14
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.07
1.83
Cdh Tj = +2 °C
0.997
0.998
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.15
3.3
Cdh Tj = +7 °C
0.991
0.995
Pdh Tj = 12°C
5.47 kW
5.15 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.98
0.983
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.07
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.07
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3178 kWh
4518 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
133 %
Prated
14 kW
14 kW
SCOP
4.52
3.39
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.38 kW
12.38 kW
COP Tj = -7°C
2.74
1.7
Cdh Tj = -7 °C
0.997
0.998
Pdh Tj = +2°C
7.56 kW
7.56 kW
COP Tj = +2°C
4.5
3.45
Cdh Tj = +2 °C
0.991
0.993
Pdh Tj = +7°C
4.92 kW
4.92 kW
COP Tj = +7°C
5.72
4.65
Cdh Tj = +7 °C
0.983
0.986
Pdh Tj = 12°C
5.55 kW
5.25 kW
COP Tj = 12°C
7.37
6.29
Cdh Tj = +12 °C
0.98
0.982
Pdh Tj = Tbiv
12.38 kW
12.38 kW
COP Tj = Tbiv
2.74
1.7
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.44
1.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6396 kWh
8524 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
161 %
COP
3.78
Heating up time
1:39 h:min
Standby power input
38.9 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
133 %
COP
3.17
Heating up time
1:48 h:min
Standby power input
41.7 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12 kW
12 kW
El input
2.67 kW
4.29 kW
COP
4.5
2.8
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
232 %
163 %
Prated
14 kW
14 kW
SCOP
5.89
4.14
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.07
1.83
Cdh Tj = +2 °C
0.997
0.998
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.15
3.3
Cdh Tj = +7 °C
0.991
0.995
Pdh Tj = 12°C
5.47 kW
5.15 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.98
0.983
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.07
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.07
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3178 kWh
4518 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
133 %
Prated
14 kW
14 kW
SCOP
4.52
3.39
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.38 kW
12.38 kW
COP Tj = -7°C
2.74
1.7
Cdh Tj = -7 °C
0.997
0.998
Pdh Tj = +2°C
7.56 kW
7.56 kW
COP Tj = +2°C
4.5
3.45
Cdh Tj = +2 °C
0.991
0.993
Pdh Tj = +7°C
4.92 kW
4.92 kW
COP Tj = +7°C
5.72
4.65
Cdh Tj = +7 °C
0.983
0.986
Pdh Tj = 12°C
5.55 kW
5.25 kW
COP Tj = 12°C
7.37
6.29
Cdh Tj = +12 °C
0.98
0.982
Pdh Tj = Tbiv
12.38 kW
12.38 kW
COP Tj = Tbiv
2.74
1.7
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.44
1.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6396 kWh
8524 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12 kW
12 kW
El input
2.67 kW
4.29 kW
COP
4.5
2.8
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
232 %
163 %
Prated
14 kW
14 kW
SCOP
5.89
4.14
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.07
1.83
Cdh Tj = +2 °C
0.997
0.998
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.15
3.3
Cdh Tj = +7 °C
0.991
0.995
Pdh Tj = 12°C
5.47 kW
5.15 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.98
0.983
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.07
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.07
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3178 kWh
4518 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
133 %
Prated
14 kW
14 kW
SCOP
4.52
3.39
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.38 kW
12.38 kW
COP Tj = -7°C
2.74
1.7
Cdh Tj = -7 °C
0.997
0.998
Pdh Tj = +2°C
7.56 kW
7.56 kW
COP Tj = +2°C
4.5
3.45
Cdh Tj = +2 °C
0.991
0.993
Pdh Tj = +7°C
4.92 kW
4.92 kW
COP Tj = +7°C
5.72
4.65
Cdh Tj = +7 °C
0.983
0.986
Pdh Tj = 12°C
5.55 kW
5.25 kW
COP Tj = 12°C
7.37
6.29
Cdh Tj = +12 °C
0.98
0.982
Pdh Tj = Tbiv
12.38 kW
12.38 kW
COP Tj = Tbiv
2.74
1.7
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.44
1.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6396 kWh
8524 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12 kW
12 kW
El input
2.67 kW
4.29 kW
COP
4.5
2.8
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
225 %
159 %
Prated
14 kW
14 kW
SCOP
5.69
4.04
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.07
1.83
Cdh Tj = +2 °C
0.995
0.997
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.15
3.3
Cdh Tj = +7 °C
0.987
0.992
Pdh Tj = 12°C
5.47 kW
5.15 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.97
0.975
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.07
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.07
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.997
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3286 kWh
4625 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
131 %
Prated
14 kW
14 kW
SCOP
4.46
3.36
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.38 kW
12.38 kW
COP Tj = -7°C
2.74
1.7
Cdh Tj = -7 °C
0.995
0.997
Pdh Tj = +2°C
7.56 kW
7.56 kW
COP Tj = +2°C
4.5
3.45
Cdh Tj = +2 °C
0.987
0.99
Pdh Tj = +7°C
4.92 kW
4.92 kW
COP Tj = +7°C
5.72
4.65
Cdh Tj = +7 °C
0.974
0.979
Pdh Tj = 12°C
5.55 kW
5.25 kW
COP Tj = 12°C
7.37
6.29
Cdh Tj = +12 °C
0.971
0.974
Pdh Tj = Tbiv
12.38 kW
12.38 kW
COP Tj = Tbiv
2.74
1.7
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.44
1.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.998
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6485 kWh
8612 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
161 %
COP
3.78
Heating up time
1:39 h:min
Standby power input
38.9 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
133 %
COP
3.17
Heating up time
1:48 h:min
Standby power input
41.7 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12 kW
12 kW
El input
2.67 kW
4.29 kW
COP
4.5
2.8
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
225 %
159 %
Prated
14 kW
14 kW
SCOP
5.69
4.04
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.07
1.83
Cdh Tj = +2 °C
0.995
0.997
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.15
3.3
Cdh Tj = +7 °C
0.987
0.992
Pdh Tj = 12°C
5.47 kW
5.15 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.97
0.975
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.07
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.07
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.997
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3286 kWh
4625 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
131 %
Prated
14 kW
14 kW
SCOP
4.46
3.36
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.38 kW
12.38 kW
COP Tj = -7°C
2.74
1.7
Cdh Tj = -7 °C
0.995
0.997
Pdh Tj = +2°C
7.56 kW
7.56 kW
COP Tj = +2°C
4.5
3.45
Cdh Tj = +2 °C
0.987
0.99
Pdh Tj = +7°C
4.92 kW
4.92 kW
COP Tj = +7°C
5.72
4.65
Cdh Tj = +7 °C
0.974
0.979
Pdh Tj = 12°C
5.55 kW
5.25 kW
COP Tj = 12°C
7.37
6.29
Cdh Tj = +12 °C
0.971
0.974
Pdh Tj = Tbiv
12.38 kW
12.38 kW
COP Tj = Tbiv
2.74
1.7
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.44
1.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.998
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6485 kWh
8612 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
161 %
COP
3.78
Heating up time
1:39 h:min
Standby power input
38.9 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
133 %
COP
3.17
Heating up time
1:48 h:min
Standby power input
41.7 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12 kW
12 kW
El input
2.67 kW
4.29 kW
COP
4.5
2.8
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
232 %
162 %
Prated
14 kW
14 kW
SCOP
5.87
4.13
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.07
1.83
Cdh Tj = +2 °C
0.995
0.997
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.15
3.3
Cdh Tj = +7 °C
0.987
0.992
Pdh Tj = 12°C
5.47 kW
5.15 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.97
0.975
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.07
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.07
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.997
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3189 kWh
4528 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
133 %
Prated
14 kW
14 kW
SCOP
4.52
3.39
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.38 kW
12.38 kW
COP Tj = -7°C
2.74
1.7
Cdh Tj = -7 °C
0.995
0.997
Pdh Tj = +2°C
7.56 kW
7.56 kW
COP Tj = +2°C
4.5
3.45
Cdh Tj = +2 °C
0.987
0.99
Pdh Tj = +7°C
4.92 kW
4.92 kW
COP Tj = +7°C
5.72
4.65
Cdh Tj = +7 °C
0.974
0.979
Pdh Tj = 12°C
5.55 kW
5.25 kW
COP Tj = 12°C
7.37
6.29
Cdh Tj = +12 °C
0.971
0.974
Pdh Tj = Tbiv
12.38 kW
12.38 kW
COP Tj = Tbiv
2.74
1.7
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.44
1.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.998
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6404 kWh
8531 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
161 %
COP
3.78
Heating up time
1:39 h:min
Standby power input
38.9 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
133 %
COP
3.17
Heating up time
1:48 h:min
Standby power input
41.7 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12 kW
12 kW
El input
2.67 kW
4.29 kW
COP
4.5
2.8
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
232 %
162 %
Prated
14 kW
14 kW
SCOP
5.87
4.13
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.07
1.83
Cdh Tj = +2 °C
0.995
0.997
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.15
3.3
Cdh Tj = +7 °C
0.987
0.992
Pdh Tj = 12°C
5.47 kW
5.15 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.97
0.975
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.07
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.07
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.997
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3189 kWh
4528 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
133 %
Prated
14 kW
14 kW
SCOP
4.52
3.39
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.38 kW
12.38 kW
COP Tj = -7°C
2.74
1.7
Cdh Tj = -7 °C
0.995
0.997
Pdh Tj = +2°C
7.56 kW
7.56 kW
COP Tj = +2°C
4.5
3.45
Cdh Tj = +2 °C
0.987
0.99
Pdh Tj = +7°C
4.92 kW
4.92 kW
COP Tj = +7°C
5.72
4.65
Cdh Tj = +7 °C
0.974
0.979
Pdh Tj = 12°C
5.55 kW
5.25 kW
COP Tj = 12°C
7.37
6.29
Cdh Tj = +12 °C
0.971
0.974
Pdh Tj = Tbiv
12.38 kW
12.38 kW
COP Tj = Tbiv
2.74
1.7
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.44
1.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.998
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6404 kWh
8531 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12 kW
12 kW
El input
2.67 kW
4.29 kW
COP
4.5
2.8
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
232 %
162 %
Prated
14 kW
14 kW
SCOP
5.87
4.13
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
14 kW
14 kW
COP Tj = +2°C
3.07
1.83
Cdh Tj = +2 °C
0.995
0.997
Pdh Tj = +7°C
9 kW
9 kW
COP Tj = +7°C
5.15
3.3
Cdh Tj = +7 °C
0.987
0.992
Pdh Tj = 12°C
5.47 kW
5.15 kW
COP Tj = 12°C
7.43
5.91
Cdh Tj = +12 °C
0.97
0.975
Pdh Tj = Tbiv
14 kW
14 kW
COP Tj = Tbiv
3.07
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14 kW
14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.07
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.997
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3189 kWh
4528 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
133 %
Prated
14 kW
14 kW
SCOP
4.52
3.39
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.38 kW
12.38 kW
COP Tj = -7°C
2.74
1.7
Cdh Tj = -7 °C
0.995
0.997
Pdh Tj = +2°C
7.56 kW
7.56 kW
COP Tj = +2°C
4.5
3.45
Cdh Tj = +2 °C
0.987
0.99
Pdh Tj = +7°C
4.92 kW
4.92 kW
COP Tj = +7°C
5.72
4.65
Cdh Tj = +7 °C
0.974
0.979
Pdh Tj = 12°C
5.55 kW
5.25 kW
COP Tj = 12°C
7.37
6.29
Cdh Tj = +12 °C
0.971
0.974
Pdh Tj = Tbiv
12.38 kW
12.38 kW
COP Tj = Tbiv
2.74
1.7
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.9 kW
13.9 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.44
1.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.998
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.1 kW
0.1 kW
Annual energy consumption Qhe
6404 kWh
8531 kWh