Certificate holders

Subtype

Ecodan Zubadan 14-200D Packaged

Certificate Holder
Mitsubishi Electric Air Conditioning Systems Europe LTD
Nettlehill Road, Houston Industrial Estate
EH54 5EQ Livingston
United Kingdom
Registration number
037-0035-20 / rev. 2
Certification Body
SZU - Strojirensky zkusebni ustav (Engineering Test Institute, Public Enterprise)
Subtype title
Ecodan Zubadan 14-200D Packaged
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

3,300 kg

Certification Date
19.12.2023
Testing basis
HP Keymark scheme rules rev. no. 6
Generate PDF Export model CSV Download certificate
  • Number of models 24

Models

PUZ-HWM140VHA(-BS) + EHPT20X-M*D
Configure model
Model name
PUZ-HWM140VHA(-BS) + EHPT20X-M*D
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14 kW

14 kW

El input

3.14 kW

5.24 kW

COP

4.46

2.67

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

160 %

Prated

14 kW

14 kW

SCOP

5.75

4.07

Tbiv

2 °C

2 °C

TOL

-28 °C

-28 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.15

1.94

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.1

3.25

Cdh Tj = +7 °C

0.99

1

Pdh Tj = 12°C

5.5 kW

5.2 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.15

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.94

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3252 kWh

4593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

132 %

Prated

14 kW

14 kW

SCOP

4.47

3.37

Tbiv

-7 °C

-7 °C

TOL

-28 °C

-28 °C

Pdh Tj = -7°C

12.4 kW

12.4 kW

COP Tj = -7°C

2.55

1.98

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

7.5 kW

7.5 kW

COP Tj = +2°C

4.4

3.25

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.9 kW

5.1 kW

COP Tj = +7°C

6.28

4.64

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.7 kW

5.2 kW

COP Tj = 12°C

7.43

6.24

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.4 kW

12.4 kW

COP Tj = Tbiv

2.55

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.4

1.75

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6470 kWh

8589 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

152 %

COP

3.58

Heating up time

01:34 h:min

Standby power input

35 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

130 %

COP

3.07

Heating up time

01:46 h:min

Standby power input

38 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

PUZ-HWM140VHA(-BS) + EHPT20X-*M*D
Configure model
Model name
PUZ-HWM140VHA(-BS) + EHPT20X-*M*D
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14 kW

14 kW

El input

3.14 kW

5.24 kW

COP

4.46

2.67

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

160 %

Prated

14 kW

14 kW

SCOP

5.75

4.07

Tbiv

2 °C

2 °C

TOL

-28 °C

-28 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.15

1.94

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.1

3.25

Cdh Tj = +7 °C

0.99

1

Pdh Tj = 12°C

5.5 kW

5.2 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.15

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.94

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3252 kWh

4593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

132 %

Prated

14 kW

14 kW

SCOP

4.47

3.37

Tbiv

-7 °C

-7 °C

TOL

-28 °C

-28 °C

Pdh Tj = -7°C

12.4 kW

12.4 kW

COP Tj = -7°C

2.55

1.98

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

7.5 kW

7.5 kW

COP Tj = +2°C

4.4

3.25

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.9 kW

5.1 kW

COP Tj = +7°C

6.28

4.64

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.7 kW

5.2 kW

COP Tj = 12°C

7.43

6.24

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.4 kW

12.4 kW

COP Tj = Tbiv

2.55

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.4

1.75

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6470 kWh

8589 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

152 %

COP

3.58

Heating up time

01:34 h:min

Standby power input

35 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

130 %

COP

3.07

Heating up time

01:46 h:min

Standby power input

38 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

PUZ-HWM140VHA(-BS) + EHPX-M*D
Configure model
Model name
PUZ-HWM140VHA(-BS) + EHPX-M*D
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14 kW

14 kW

El input

3.14 kW

5.24 kW

COP

4.46

2.67

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

160 %

Prated

14 kW

14 kW

SCOP

5.75

4.07

Tbiv

2 °C

2 °C

TOL

-28 °C

-28 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.15

1.94

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.1

3.25

Cdh Tj = +7 °C

0.99

1

Pdh Tj = 12°C

5.5 kW

5.2 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.15

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.94

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3252 kWh

4593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

132 %

Prated

14 kW

14 kW

SCOP

4.47

3.37

Tbiv

-7 °C

-7 °C

TOL

-28 °C

-28 °C

Pdh Tj = -7°C

12.4 kW

12.4 kW

COP Tj = -7°C

2.55

1.98

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

7.5 kW

7.5 kW

COP Tj = +2°C

4.4

3.25

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.9 kW

5.1 kW

COP Tj = +7°C

6.28

4.64

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.7 kW

5.2 kW

COP Tj = 12°C

7.43

6.24

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.4 kW

12.4 kW

COP Tj = Tbiv

2.55

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.4

1.75

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6470 kWh

8589 kWh

PUZ-HWM140VHA(-BS) + EHPX-*M*D
Configure model
Model name
PUZ-HWM140VHA(-BS) + EHPX-*M*D
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14 kW

14 kW

El input

3.14 kW

5.24 kW

COP

4.46

2.67

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

160 %

Prated

14 kW

14 kW

SCOP

5.75

4.07

Tbiv

2 °C

2 °C

TOL

-28 °C

-28 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.15

1.94

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.1

3.25

Cdh Tj = +7 °C

0.99

1

Pdh Tj = 12°C

5.5 kW

5.2 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.15

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.94

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3252 kWh

4593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

132 %

Prated

14 kW

14 kW

SCOP

4.47

3.37

Tbiv

-7 °C

-7 °C

TOL

-28 °C

-28 °C

Pdh Tj = -7°C

12.4 kW

12.4 kW

COP Tj = -7°C

2.55

1.98

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

7.5 kW

7.5 kW

COP Tj = +2°C

4.4

3.25

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.9 kW

5.1 kW

COP Tj = +7°C

6.28

4.64

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.7 kW

5.2 kW

COP Tj = 12°C

7.43

6.24

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.4 kW

12.4 kW

COP Tj = Tbiv

2.55

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.4

1.75

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6470 kWh

8589 kWh

PUZ-HWM140VHA(-BS) + ERPT20X-M*D
Configure model
Model name
PUZ-HWM140VHA(-BS) + ERPT20X-M*D
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14 kW

14 kW

El input

3.14 kW

5.24 kW

COP

4.46

2.67

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

232 %

162 %

Prated

14 kW

14 kW

SCOP

5.87

4.13

Tbiv

2 °C

2 °C

TOL

-28 °C

-28 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.15

1.94

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.1

3.25

Cdh Tj = +7 °C

0.99

1

Pdh Tj = 12°C

5.5 kW

5.2 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.15

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.94

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3186 kWh

4527 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

133 %

Prated

14 kW

14 kW

SCOP

4.51

3.39

Tbiv

-7 °C

-7 °C

TOL

-28 °C

-28 °C

Pdh Tj = -7°C

12.4 kW

12.4 kW

COP Tj = -7°C

2.55

1.98

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

7.5 kW

7.5 kW

COP Tj = +2°C

4.4

3.25

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.9 kW

5.1 kW

COP Tj = +7°C

6.28

4.64

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.7 kW

5.2 kW

COP Tj = 12°C

7.43

6.24

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.4 kW

12.4 kW

COP Tj = Tbiv

2.55

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.4

1.75

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6407 kWh

8534 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

152 %

COP

3.58

Heating up time

01:34 h:min

Standby power input

35 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

130 %

COP

3.07

Heating up time

01:46 h:min

Standby power input

38 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

PUZ-HWM140VHA(-BS) + ERPT20X-*M*D
Configure model
Model name
PUZ-HWM140VHA(-BS) + ERPT20X-*M*D
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14 kW

14 kW

El input

3.14 kW

5.24 kW

COP

4.46

2.67

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

232 %

162 %

Prated

14 kW

14 kW

SCOP

5.87

4.13

Tbiv

2 °C

2 °C

TOL

-28 °C

-28 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.15

1.94

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.1

3.25

Cdh Tj = +7 °C

0.99

1

Pdh Tj = 12°C

5.5 kW

5.2 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.15

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.94

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3186 kWh

4527 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

133 %

Prated

14 kW

14 kW

SCOP

4.51

3.39

Tbiv

-7 °C

-7 °C

TOL

-28 °C

-28 °C

Pdh Tj = -7°C

12.4 kW

12.4 kW

COP Tj = -7°C

2.55

1.98

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

7.5 kW

7.5 kW

COP Tj = +2°C

4.4

3.25

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.9 kW

5.1 kW

COP Tj = +7°C

6.28

4.64

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.7 kW

5.2 kW

COP Tj = 12°C

7.43

6.24

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.4 kW

12.4 kW

COP Tj = Tbiv

2.55

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.4

1.75

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6407 kWh

8534 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

152 %

COP

3.58

Heating up time

01:34 h:min

Standby power input

35 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

130 %

COP

3.07

Heating up time

01:46 h:min

Standby power input

38 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

PUZ-HWM140VHA(-BS)
Configure model
Model name
PUZ-HWM140VHA(-BS)
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14 kW

14 kW

El input

3.14 kW

5.24 kW

COP

4.46

2.67

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

232 %

162 %

Prated

14 kW

14 kW

SCOP

5.87

4.13

Tbiv

2 °C

2 °C

TOL

-28 °C

-28 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.15

1.94

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.1

3.25

Cdh Tj = +7 °C

0.99

1

Pdh Tj = 12°C

5.5 kW

5.2 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.15

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.94

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3186 kWh

4527 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

133 %

Prated

14 kW

14 kW

SCOP

4.51

3.39

Tbiv

-7 °C

-7 °C

TOL

-28 °C

-28 °C

Pdh Tj = -7°C

12.4 kW

12.4 kW

COP Tj = -7°C

2.55

1.98

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

7.5 kW

7.5 kW

COP Tj = +2°C

4.4

3.25

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.9 kW

5.1 kW

COP Tj = +7°C

6.28

4.64

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.7 kW

5.2 kW

COP Tj = 12°C

7.43

6.24

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.4 kW

12.4 kW

COP Tj = Tbiv

2.55

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.4

1.75

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6407 kWh

8534 kWh

PUZ-HWM140YHA(-BS) + EHPT20X-M*D
Configure model
Model name
PUZ-HWM140YHA(-BS) + EHPT20X-M*D
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14 kW

14 kW

El input

3.14 kW

5.24 kW

COP

4.46

2.67

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

225 %

159 %

Prated

14 kW

14 kW

SCOP

5.69

4.04

Tbiv

2 °C

2 °C

TOL

-28 °C

-28 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.15

1.94

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.12

3.26

Cdh Tj = +7 °C

0.99

1

Pdh Tj = 12°C

5.5 kW

5.2 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.15

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.94

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3288 kWh

4628 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

131 %

Prated

14 kW

14 kW

SCOP

4.46

3.36

Tbiv

-7 °C

-7 °C

TOL

-28 °C

-28 °C

Pdh Tj = -7°C

12.4 kW

12.4 kW

COP Tj = -7°C

2.55

1.98

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

7.5 kW

7.5 kW

COP Tj = +2°C

4.42

3.26

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.9 kW

5.1 kW

COP Tj = +7°C

6.26

4.64

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.7 kW

5.2 kW

COP Tj = 12°C

7.43

6.24

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.4 kW

12.4 kW

COP Tj = Tbiv

2.55

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.4

1.75

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6492 kWh

8608 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

152 %

COP

3.58

Heating up time

01:34 h:min

Standby power input

35 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

130 %

COP

3.07

Heating up time

01:46 h:min

Standby power input

38 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

PUZ-HWM140YHA(-BS) + EHPT20X-*M*D
Configure model
Model name
PUZ-HWM140YHA(-BS) + EHPT20X-*M*D
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14 kW

14 kW

El input

3.14 kW

5.24 kW

COP

4.46

2.67

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

225 %

159 %

Prated

14 kW

14 kW

SCOP

5.69

4.04

Tbiv

2 °C

2 °C

TOL

-28 °C

-28 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.15

1.94

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.12

3.26

Cdh Tj = +7 °C

0.99

1

Pdh Tj = 12°C

5.5 kW

5.2 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.15

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.94

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3288 kWh

4628 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

131 %

Prated

14 kW

14 kW

SCOP

4.46

3.36

Tbiv

-7 °C

-7 °C

TOL

-28 °C

-28 °C

Pdh Tj = -7°C

12.4 kW

12.4 kW

COP Tj = -7°C

2.55

1.98

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

7.5 kW

7.5 kW

COP Tj = +2°C

4.42

3.26

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.9 kW

5.1 kW

COP Tj = +7°C

6.26

4.64

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.7 kW

5.2 kW

COP Tj = 12°C

7.43

6.24

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.4 kW

12.4 kW

COP Tj = Tbiv

2.55

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.4

1.75

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6492 kWh

8608 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

152 %

COP

3.58

Heating up time

01:34 h:min

Standby power input

35 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

130 %

COP

3.07

Heating up time

01:46 h:min

Standby power input

38 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

PUZ-HWM140YHA(-BS) + EHPX-M*D
Configure model
Model name
PUZ-HWM140YHA(-BS) + EHPX-M*D
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14 kW

14 kW

El input

3.14 kW

5.24 kW

COP

4.46

2.67

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

225 %

159 %

Prated

14 kW

14 kW

SCOP

5.69

4.04

Tbiv

2 °C

2 °C

TOL

-28 °C

-28 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.15

1.94

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.12

3.26

Cdh Tj = +7 °C

0.99

1

Pdh Tj = 12°C

5.5 kW

5.2 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.15

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.94

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3288 kWh

4628 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

131 %

Prated

14 kW

14 kW

SCOP

4.46

3.36

Tbiv

-7 °C

-7 °C

TOL

-28 °C

-28 °C

Pdh Tj = -7°C

12.4 kW

12.4 kW

COP Tj = -7°C

2.55

1.98

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

7.5 kW

7.5 kW

COP Tj = +2°C

4.42

3.26

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.9 kW

5.1 kW

COP Tj = +7°C

6.26

4.64

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.7 kW

5.2 kW

COP Tj = 12°C

7.43

6.24

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.4 kW

12.4 kW

COP Tj = Tbiv

2.55

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.4

1.75

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6492 kWh

8608 kWh

PUZ-HWM140YHA(-BS) + EHPX-*M*D
Configure model
Model name
PUZ-HWM140YHA(-BS) + EHPX-*M*D
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14 kW

14 kW

El input

3.14 kW

5.24 kW

COP

4.46

2.67

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

225 %

159 %

Prated

14 kW

14 kW

SCOP

5.69

4.04

Tbiv

2 °C

2 °C

TOL

-28 °C

-28 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.15

1.94

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.12

3.26

Cdh Tj = +7 °C

0.99

1

Pdh Tj = 12°C

5.5 kW

5.2 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.15

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.94

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3288 kWh

4628 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

131 %

Prated

14 kW

14 kW

SCOP

4.46

3.36

Tbiv

-7 °C

-7 °C

TOL

-28 °C

-28 °C

Pdh Tj = -7°C

12.4 kW

12.4 kW

COP Tj = -7°C

2.55

1.98

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

7.5 kW

7.5 kW

COP Tj = +2°C

4.42

3.26

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.9 kW

5.1 kW

COP Tj = +7°C

6.26

4.64

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.7 kW

5.2 kW

COP Tj = 12°C

7.43

6.24

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.4 kW

12.4 kW

COP Tj = Tbiv

2.55

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.4

1.75

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6492 kWh

8608 kWh

PUZ-HWM140YHA(-BS) + ERPT20X-M*D
Configure model
Model name
PUZ-HWM140YHA(-BS) + ERPT20X-M*D
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14 kW

14 kW

El input

3.14 kW

5.24 kW

COP

4.46

2.67

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

231 %

162 %

Prated

14 kW

14 kW

SCOP

5.86

4.13

Tbiv

2 °C

2 °C

TOL

-28 °C

-28 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.15

1.94

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.12

3.26

Cdh Tj = +7 °C

0.99

1

Pdh Tj = 12°C

5.5 kW

5.2 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.15

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.94

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3191 kWh

4531 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

133 %

Prated

14 kW

14 kW

SCOP

4.51

3.39

Tbiv

-7 °C

-7 °C

TOL

-28 °C

-28 °C

Pdh Tj = -7°C

12.4 kW

12.4 kW

COP Tj = -7°C

2.55

1.98

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

7.5 kW

7.5 kW

COP Tj = +2°C

4.42

3.26

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.9 kW

5.1 kW

COP Tj = +7°C

6.26

4.64

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.7 kW

5.2 kW

COP Tj = 12°C

7.43

6.24

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.4 kW

12.4 kW

COP Tj = Tbiv

2.55

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.4

1.75

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6412 kWh

8528 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

152 %

COP

3.58

Heating up time

01:34 h:min

Standby power input

35 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

130 %

COP

3.07

Heating up time

01:46 h:min

Standby power input

38 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

PUZ-HWM140YHA(-BS) + ERPT20X-*M*D
Configure model
Model name
PUZ-HWM140YHA(-BS) + ERPT20X-*M*D
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14 kW

14 kW

El input

3.14 kW

5.24 kW

COP

4.46

2.67

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

231 %

162 %

Prated

14 kW

14 kW

SCOP

5.86

4.13

Tbiv

2 °C

2 °C

TOL

-28 °C

-28 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.15

1.94

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.12

3.26

Cdh Tj = +7 °C

0.99

1

Pdh Tj = 12°C

5.5 kW

5.2 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.15

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.94

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3191 kWh

4531 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

133 %

Prated

14 kW

14 kW

SCOP

4.51

3.39

Tbiv

-7 °C

-7 °C

TOL

-28 °C

-28 °C

Pdh Tj = -7°C

12.4 kW

12.4 kW

COP Tj = -7°C

2.55

1.98

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

7.5 kW

7.5 kW

COP Tj = +2°C

4.42

3.26

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.9 kW

5.1 kW

COP Tj = +7°C

6.26

4.64

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.7 kW

5.2 kW

COP Tj = 12°C

7.43

6.24

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.4 kW

12.4 kW

COP Tj = Tbiv

2.55

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.4

1.75

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6412 kWh

8528 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

152 %

COP

3.58

Heating up time

01:34 h:min

Standby power input

35 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

130 %

COP

3.07

Heating up time

01:46 h:min

Standby power input

38 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

PUZ-HWM140YHA(-BS)
Configure model
Model name
PUZ-HWM140YHA(-BS)
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14 kW

14 kW

El input

3.14 kW

5.24 kW

COP

4.46

2.67

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

231 %

162 %

Prated

14 kW

14 kW

SCOP

5.86

4.13

Tbiv

2 °C

2 °C

TOL

-28 °C

-28 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.15

1.94

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.12

3.26

Cdh Tj = +7 °C

0.99

1

Pdh Tj = 12°C

5.5 kW

5.2 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.15

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.94

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3191 kWh

4531 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

133 %

Prated

14 kW

14 kW

SCOP

4.51

3.39

Tbiv

-7 °C

-7 °C

TOL

-28 °C

-28 °C

Pdh Tj = -7°C

12.4 kW

12.4 kW

COP Tj = -7°C

2.55

1.98

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

7.5 kW

7.5 kW

COP Tj = +2°C

4.42

3.26

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.9 kW

5.1 kW

COP Tj = +7°C

6.26

4.64

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

5.7 kW

5.2 kW

COP Tj = 12°C

7.43

6.24

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.4 kW

12.4 kW

COP Tj = Tbiv

2.55

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.4

1.75

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6412 kWh

8528 kWh

PUZ-HWM140VHA(-BS) + EHPT20X-*M*E
Configure model
Model name
PUZ-HWM140VHA(-BS) + EHPT20X-*M*E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12 kW

12 kW

El input

2.67 kW

4.29 kW

COP

4.5

2.8

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

228 %

160 %

Prated

14 kW

14 kW

SCOP

5.77

4.08

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.07

1.83

Cdh Tj = +2 °C

0.997

0.998

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.15

3.3

Cdh Tj = +7 °C

0.991

0.995

Pdh Tj = 12°C

5.47 kW

5.15 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.98

0.983

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.07

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.07

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3244 kWh

4584 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

132 %

Prated

14 kW

14 kW

SCOP

4.48

3.37

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.38 kW

12.38 kW

COP Tj = -7°C

2.74

1.7

Cdh Tj = -7 °C

0.997

0.998

Pdh Tj = +2°C

7.56 kW

7.56 kW

COP Tj = +2°C

4.5

3.45

Cdh Tj = +2 °C

0.991

0.993

Pdh Tj = +7°C

4.92 kW

4.92 kW

COP Tj = +7°C

5.72

4.65

Cdh Tj = +7 °C

0.983

0.986

Pdh Tj = 12°C

5.55 kW

5.25 kW

COP Tj = 12°C

7.37

6.29

Cdh Tj = +12 °C

0.98

0.982

Pdh Tj = Tbiv

12.38 kW

12.38 kW

COP Tj = Tbiv

2.74

1.7

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.44

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6452 kWh

8579 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

161 %

COP

3.78

Heating up time

1:39 h:min

Standby power input

38.9 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

133 %

COP

3.17

Heating up time

1:48 h:min

Standby power input

41.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

PUZ-HWM140VHA(-BS) + EHPT20X-MEHEW
Configure model
Model name
PUZ-HWM140VHA(-BS) + EHPT20X-MEHEW
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12 kW

12 kW

El input

2.67 kW

4.29 kW

COP

4.5

2.8

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

228 %

160 %

Prated

14 kW

14 kW

SCOP

5.77

4.08

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.07

1.83

Cdh Tj = +2 °C

0.997

0.998

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.15

3.3

Cdh Tj = +7 °C

0.991

0.995

Pdh Tj = 12°C

5.47 kW

5.15 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.98

0.983

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.07

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.07

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3244 kWh

4584 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

132 %

Prated

14 kW

14 kW

SCOP

4.48

3.37

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.38 kW

12.38 kW

COP Tj = -7°C

2.74

1.7

Cdh Tj = -7 °C

0.997

0.998

Pdh Tj = +2°C

7.56 kW

7.56 kW

COP Tj = +2°C

4.5

3.45

Cdh Tj = +2 °C

0.991

0.993

Pdh Tj = +7°C

4.92 kW

4.92 kW

COP Tj = +7°C

5.72

4.65

Cdh Tj = +7 °C

0.983

0.986

Pdh Tj = 12°C

5.55 kW

5.25 kW

COP Tj = 12°C

7.37

6.29

Cdh Tj = +12 °C

0.98

0.982

Pdh Tj = Tbiv

12.38 kW

12.38 kW

COP Tj = Tbiv

2.74

1.7

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.44

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6452 kWh

8579 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

161 %

COP

3.78

Heating up time

1:39 h:min

Standby power input

38.9 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

133 %

COP

3.17

Heating up time

1:48 h:min

Standby power input

41.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

PUZ-HWM140VHA(-BS) + ERPT20X-*M*E
Configure model
Model name
PUZ-HWM140VHA(-BS) + ERPT20X-*M*E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12 kW

12 kW

El input

2.67 kW

4.29 kW

COP

4.5

2.8

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

232 %

163 %

Prated

14 kW

14 kW

SCOP

5.89

4.14

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.07

1.83

Cdh Tj = +2 °C

0.997

0.998

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.15

3.3

Cdh Tj = +7 °C

0.991

0.995

Pdh Tj = 12°C

5.47 kW

5.15 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.98

0.983

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.07

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.07

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3178 kWh

4518 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

133 %

Prated

14 kW

14 kW

SCOP

4.52

3.39

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.38 kW

12.38 kW

COP Tj = -7°C

2.74

1.7

Cdh Tj = -7 °C

0.997

0.998

Pdh Tj = +2°C

7.56 kW

7.56 kW

COP Tj = +2°C

4.5

3.45

Cdh Tj = +2 °C

0.991

0.993

Pdh Tj = +7°C

4.92 kW

4.92 kW

COP Tj = +7°C

5.72

4.65

Cdh Tj = +7 °C

0.983

0.986

Pdh Tj = 12°C

5.55 kW

5.25 kW

COP Tj = 12°C

7.37

6.29

Cdh Tj = +12 °C

0.98

0.982

Pdh Tj = Tbiv

12.38 kW

12.38 kW

COP Tj = Tbiv

2.74

1.7

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.44

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6396 kWh

8524 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

161 %

COP

3.78

Heating up time

1:39 h:min

Standby power input

38.9 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

133 %

COP

3.17

Heating up time

1:48 h:min

Standby power input

41.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

PUZ-HWM140VHA(-BS) + ERPX-M*E
Configure model
Model name
PUZ-HWM140VHA(-BS) + ERPX-M*E
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12 kW

12 kW

El input

2.67 kW

4.29 kW

COP

4.5

2.8

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

232 %

163 %

Prated

14 kW

14 kW

SCOP

5.89

4.14

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.07

1.83

Cdh Tj = +2 °C

0.997

0.998

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.15

3.3

Cdh Tj = +7 °C

0.991

0.995

Pdh Tj = 12°C

5.47 kW

5.15 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.98

0.983

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.07

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.07

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3178 kWh

4518 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

133 %

Prated

14 kW

14 kW

SCOP

4.52

3.39

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.38 kW

12.38 kW

COP Tj = -7°C

2.74

1.7

Cdh Tj = -7 °C

0.997

0.998

Pdh Tj = +2°C

7.56 kW

7.56 kW

COP Tj = +2°C

4.5

3.45

Cdh Tj = +2 °C

0.991

0.993

Pdh Tj = +7°C

4.92 kW

4.92 kW

COP Tj = +7°C

5.72

4.65

Cdh Tj = +7 °C

0.983

0.986

Pdh Tj = 12°C

5.55 kW

5.25 kW

COP Tj = 12°C

7.37

6.29

Cdh Tj = +12 °C

0.98

0.982

Pdh Tj = Tbiv

12.38 kW

12.38 kW

COP Tj = Tbiv

2.74

1.7

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.44

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6396 kWh

8524 kWh

PUZ-HWM140VHA(-BS) + ERPX-*M*E
Configure model
Model name
PUZ-HWM140VHA(-BS) + ERPX-*M*E
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12 kW

12 kW

El input

2.67 kW

4.29 kW

COP

4.5

2.8

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

232 %

163 %

Prated

14 kW

14 kW

SCOP

5.89

4.14

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.07

1.83

Cdh Tj = +2 °C

0.997

0.998

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.15

3.3

Cdh Tj = +7 °C

0.991

0.995

Pdh Tj = 12°C

5.47 kW

5.15 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.98

0.983

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.07

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.07

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3178 kWh

4518 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

133 %

Prated

14 kW

14 kW

SCOP

4.52

3.39

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.38 kW

12.38 kW

COP Tj = -7°C

2.74

1.7

Cdh Tj = -7 °C

0.997

0.998

Pdh Tj = +2°C

7.56 kW

7.56 kW

COP Tj = +2°C

4.5

3.45

Cdh Tj = +2 °C

0.991

0.993

Pdh Tj = +7°C

4.92 kW

4.92 kW

COP Tj = +7°C

5.72

4.65

Cdh Tj = +7 °C

0.983

0.986

Pdh Tj = 12°C

5.55 kW

5.25 kW

COP Tj = 12°C

7.37

6.29

Cdh Tj = +12 °C

0.98

0.982

Pdh Tj = Tbiv

12.38 kW

12.38 kW

COP Tj = Tbiv

2.74

1.7

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.44

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6396 kWh

8524 kWh

PUZ-HWM140YHA(-BS) + EHPT20X-*M*E
Configure model
Model name
PUZ-HWM140YHA(-BS) + EHPT20X-*M*E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12 kW

12 kW

El input

2.67 kW

4.29 kW

COP

4.5

2.8

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

225 %

159 %

Prated

14 kW

14 kW

SCOP

5.69

4.04

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.07

1.83

Cdh Tj = +2 °C

0.995

0.997

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.15

3.3

Cdh Tj = +7 °C

0.987

0.992

Pdh Tj = 12°C

5.47 kW

5.15 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.97

0.975

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.07

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.07

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.995

0.997

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3286 kWh

4625 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

131 %

Prated

14 kW

14 kW

SCOP

4.46

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.38 kW

12.38 kW

COP Tj = -7°C

2.74

1.7

Cdh Tj = -7 °C

0.995

0.997

Pdh Tj = +2°C

7.56 kW

7.56 kW

COP Tj = +2°C

4.5

3.45

Cdh Tj = +2 °C

0.987

0.99

Pdh Tj = +7°C

4.92 kW

4.92 kW

COP Tj = +7°C

5.72

4.65

Cdh Tj = +7 °C

0.974

0.979

Pdh Tj = 12°C

5.55 kW

5.25 kW

COP Tj = 12°C

7.37

6.29

Cdh Tj = +12 °C

0.971

0.974

Pdh Tj = Tbiv

12.38 kW

12.38 kW

COP Tj = Tbiv

2.74

1.7

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.44

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.998

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6485 kWh

8612 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

161 %

COP

3.78

Heating up time

1:39 h:min

Standby power input

38.9 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

133 %

COP

3.17

Heating up time

1:48 h:min

Standby power input

41.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

PUZ-HWM140YHA(-BS) + EHPT20X-MEHEW
Configure model
Model name
PUZ-HWM140YHA(-BS) + EHPT20X-MEHEW
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12 kW

12 kW

El input

2.67 kW

4.29 kW

COP

4.5

2.8

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

225 %

159 %

Prated

14 kW

14 kW

SCOP

5.69

4.04

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.07

1.83

Cdh Tj = +2 °C

0.995

0.997

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.15

3.3

Cdh Tj = +7 °C

0.987

0.992

Pdh Tj = 12°C

5.47 kW

5.15 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.97

0.975

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.07

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.07

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.995

0.997

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3286 kWh

4625 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

131 %

Prated

14 kW

14 kW

SCOP

4.46

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.38 kW

12.38 kW

COP Tj = -7°C

2.74

1.7

Cdh Tj = -7 °C

0.995

0.997

Pdh Tj = +2°C

7.56 kW

7.56 kW

COP Tj = +2°C

4.5

3.45

Cdh Tj = +2 °C

0.987

0.99

Pdh Tj = +7°C

4.92 kW

4.92 kW

COP Tj = +7°C

5.72

4.65

Cdh Tj = +7 °C

0.974

0.979

Pdh Tj = 12°C

5.55 kW

5.25 kW

COP Tj = 12°C

7.37

6.29

Cdh Tj = +12 °C

0.971

0.974

Pdh Tj = Tbiv

12.38 kW

12.38 kW

COP Tj = Tbiv

2.74

1.7

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.44

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.998

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6485 kWh

8612 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

161 %

COP

3.78

Heating up time

1:39 h:min

Standby power input

38.9 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

133 %

COP

3.17

Heating up time

1:48 h:min

Standby power input

41.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

PUZ-HWM140YHA(-BS) + ERPT20X-*M*E
Configure model
Model name
PUZ-HWM140YHA(-BS) + ERPT20X-*M*E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12 kW

12 kW

El input

2.67 kW

4.29 kW

COP

4.5

2.8

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

232 %

162 %

Prated

14 kW

14 kW

SCOP

5.87

4.13

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.07

1.83

Cdh Tj = +2 °C

0.995

0.997

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.15

3.3

Cdh Tj = +7 °C

0.987

0.992

Pdh Tj = 12°C

5.47 kW

5.15 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.97

0.975

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.07

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.07

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.995

0.997

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3189 kWh

4528 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

133 %

Prated

14 kW

14 kW

SCOP

4.52

3.39

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.38 kW

12.38 kW

COP Tj = -7°C

2.74

1.7

Cdh Tj = -7 °C

0.995

0.997

Pdh Tj = +2°C

7.56 kW

7.56 kW

COP Tj = +2°C

4.5

3.45

Cdh Tj = +2 °C

0.987

0.99

Pdh Tj = +7°C

4.92 kW

4.92 kW

COP Tj = +7°C

5.72

4.65

Cdh Tj = +7 °C

0.974

0.979

Pdh Tj = 12°C

5.55 kW

5.25 kW

COP Tj = 12°C

7.37

6.29

Cdh Tj = +12 °C

0.971

0.974

Pdh Tj = Tbiv

12.38 kW

12.38 kW

COP Tj = Tbiv

2.74

1.7

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.44

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.998

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6404 kWh

8531 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

161 %

COP

3.78

Heating up time

1:39 h:min

Standby power input

38.9 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

133 %

COP

3.17

Heating up time

1:48 h:min

Standby power input

41.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

278 l

PUZ-HWM140YHA(-BS) + ERPX-M*E
Configure model
Model name
PUZ-HWM140YHA(-BS) + ERPX-M*E
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12 kW

12 kW

El input

2.67 kW

4.29 kW

COP

4.5

2.8

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

232 %

162 %

Prated

14 kW

14 kW

SCOP

5.87

4.13

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.07

1.83

Cdh Tj = +2 °C

0.995

0.997

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.15

3.3

Cdh Tj = +7 °C

0.987

0.992

Pdh Tj = 12°C

5.47 kW

5.15 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.97

0.975

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.07

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.07

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.995

0.997

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3189 kWh

4528 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

133 %

Prated

14 kW

14 kW

SCOP

4.52

3.39

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.38 kW

12.38 kW

COP Tj = -7°C

2.74

1.7

Cdh Tj = -7 °C

0.995

0.997

Pdh Tj = +2°C

7.56 kW

7.56 kW

COP Tj = +2°C

4.5

3.45

Cdh Tj = +2 °C

0.987

0.99

Pdh Tj = +7°C

4.92 kW

4.92 kW

COP Tj = +7°C

5.72

4.65

Cdh Tj = +7 °C

0.974

0.979

Pdh Tj = 12°C

5.55 kW

5.25 kW

COP Tj = 12°C

7.37

6.29

Cdh Tj = +12 °C

0.971

0.974

Pdh Tj = Tbiv

12.38 kW

12.38 kW

COP Tj = Tbiv

2.74

1.7

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.44

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.998

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6404 kWh

8531 kWh

PUZ-HWM140YHA(-BS) + ERPX-*M*E
Configure model
Model name
PUZ-HWM140YHA(-BS) + ERPX-*M*E
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12 kW

12 kW

El input

2.67 kW

4.29 kW

COP

4.5

2.8

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

232 %

162 %

Prated

14 kW

14 kW

SCOP

5.87

4.13

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14 kW

14 kW

COP Tj = +2°C

3.07

1.83

Cdh Tj = +2 °C

0.995

0.997

Pdh Tj = +7°C

9 kW

9 kW

COP Tj = +7°C

5.15

3.3

Cdh Tj = +7 °C

0.987

0.992

Pdh Tj = 12°C

5.47 kW

5.15 kW

COP Tj = 12°C

7.43

5.91

Cdh Tj = +12 °C

0.97

0.975

Pdh Tj = Tbiv

14 kW

14 kW

COP Tj = Tbiv

3.07

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14 kW

14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.07

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.995

0.997

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3189 kWh

4528 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

133 %

Prated

14 kW

14 kW

SCOP

4.52

3.39

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.38 kW

12.38 kW

COP Tj = -7°C

2.74

1.7

Cdh Tj = -7 °C

0.995

0.997

Pdh Tj = +2°C

7.56 kW

7.56 kW

COP Tj = +2°C

4.5

3.45

Cdh Tj = +2 °C

0.987

0.99

Pdh Tj = +7°C

4.92 kW

4.92 kW

COP Tj = +7°C

5.72

4.65

Cdh Tj = +7 °C

0.974

0.979

Pdh Tj = 12°C

5.55 kW

5.25 kW

COP Tj = 12°C

7.37

6.29

Cdh Tj = +12 °C

0.971

0.974

Pdh Tj = Tbiv

12.38 kW

12.38 kW

COP Tj = Tbiv

2.74

1.7

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.9 kW

13.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.44

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.998

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.1 kW

0.1 kW

Annual energy consumption Qhe

6404 kWh

8531 kWh