2,000 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.00 kW
5.00 kW
El input
1.00 kW
1.62 kW
COP
5.00
3.08
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
226 %
157 %
Prated
5.00 kW
5.00 kW
SCOP
5.73
4.00
Tbiv
2 °C
2 °C
TOL
-20 °C
-20 °C
Pdh Tj = +2°C
5.00 kW
5.00 kW
COP Tj = +2°C
3.70
1.98
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.20 kW
3.20 kW
COP Tj = +7°C
5.10
3.40
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
1.90 kW
1.80 kW
COP Tj = 12°C
7.98
5.81
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
5.00 kW
5.00 kW
COP Tj = Tbiv
3.70
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
5.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.70
1.98
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1166 kWh
1671 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
129 %
Prated
5.00 kW
5.00 kW
SCOP
4.66
3.31
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
4.40 kW
4.40 kW
COP Tj = -7°C
3.17
2.04
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.70 kW
2.70 kW
COP Tj = +2°C
4.47
3.23
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
1.90 kW
1.70 kW
COP Tj = +7°C
6.55
4.47
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
1.80 kW
1.80 kW
COP Tj = 12°C
8.57
6.67
Cdh Tj = +12 °C
0.930
0.940
Pdh Tj = Tbiv
4.40 kW
4.40 kW
COP Tj = Tbiv
3.17
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.19 kW
4.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.84
1.97
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.81 kW
0.81 kW
Annual energy consumption Qhe
2216 kWh
3122 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
135 %
COP
3.19
Heating up time
2:32 h:min
Standby power input
36.0 W
Reference hot water temperature
55.5 °C
Mixed water at 40°C
236 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
120 %
COP
2.84
Heating up time
2:07 h:min
Standby power input
39.0 W
Reference hot water temperature
55.5 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.00 kW
5.00 kW
El input
1.00 kW
1.62 kW
COP
5.00
3.08
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
237 %
162 %
Prated
5.00 kW
5.00 kW
SCOP
6.00
4.13
Tbiv
2 °C
2 °C
TOL
-20 °C
-20 °C
Pdh Tj = +2°C
5.00 kW
5.00 kW
COP Tj = +2°C
3.70
1.98
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.20 kW
3.20 kW
COP Tj = +7°C
4.96
3.35
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
1.90 kW
1.80 kW
COP Tj = 12°C
8.00
5.81
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
5.00 kW
5.00 kW
COP Tj = Tbiv
3.70
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
5.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.70
1.98
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1112 kWh
1616 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
133 %
Prated
5.00 kW
5.00 kW
SCOP
4.83
3.40
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
4.40 kW
4.40 kW
COP Tj = -7°C
3.17
2.04
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.70 kW
2.70 kW
COP Tj = +2°C
4.56
3.29
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
1.90 kW
1.70 kW
COP Tj = +7°C
6.55
4.47
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
1.80 kW
1.80 kW
COP Tj = 12°C
8.57
6.67
Cdh Tj = +12 °C
0.930
0.940
Pdh Tj = Tbiv
4.40 kW
4.40 kW
COP Tj = Tbiv
3.17
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.19 kW
4.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.84
1.97
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.81 kW
0.81 kW
Annual energy consumption Qhe
2139 kWh
3038 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
135 %
COP
3.19
Heating up time
2:32 h:min
Standby power input
36.0 W
Reference hot water temperature
55.5 °C
Mixed water at 40°C
236 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
120 %
COP
2.84
Heating up time
2:07 h:min
Standby power input
39.0 W
Reference hot water temperature
55.5 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4 kW
4 kW
El input
0.77 kW
1.3 kW
COP
5.2
3.08
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
226 %
157 %
Prated
5 kW
5 kW
SCOP
5.73
4
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5 kW
5 kW
COP Tj = +2°C
3.86
2.42
Cdh Tj = +2 °C
0.988
0.993
Pdh Tj = +7°C
3.22 kW
3.23 kW
COP Tj = +7°C
5.23
3.25
Cdh Tj = +7 °C
0.976
0.985
Pdh Tj = 12°C
1.92 kW
1.82 kW
COP Tj = 12°C
7.72
5.87
Cdh Tj = +12 °C
0.94
0.952
Pdh Tj = Tbiv
5 kW
5 kW
COP Tj = Tbiv
3.86
2.42
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5 kW
5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.86
2.42
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.988
0.993
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1167 kWh
1669 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
129 %
Prated
5 kW
5 kW
SCOP
4.66
3.29
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.42 kW
4.42 kW
COP Tj = -7°C
3.42
2.28
Cdh Tj = -7 °C
0.988
0.992
Pdh Tj = +2°C
2.9 kW
2.76 kW
COP Tj = +2°C
4.38
3.29
Cdh Tj = +2 °C
0.977
0.982
Pdh Tj = +7°C
1.92 kW
1.75 kW
COP Tj = +7°C
6.62
3.87
Cdh Tj = +7 °C
0.948
0.967
Pdh Tj = 12°C
1.92 kW
1.82 kW
COP Tj = 12°C
7.74
6.45
Cdh Tj = +12 °C
0.94
0.947
Pdh Tj = Tbiv
4.42 kW
4.42 kW
COP Tj = Tbiv
3.42
2.28
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.21 kW
4.22 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.11
1.97
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.989
0.993
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.79 kW
0.78 kW
Annual energy consumption Qhe
2216 kWh
3141 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
130 %
COP
3.13
Heating up time
2:46 h:min
Standby power input
36.2 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.77
Heating up time
3:01 h:min
Standby power input
33.3 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4 kW
4 kW
El input
0.77 kW
1.3 kW
COP
5.2
3.08
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
240 %
164 %
Prated
5 kW
5 kW
SCOP
6.07
4.17
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5 kW
5 kW
COP Tj = +2°C
3.86
2.42
Cdh Tj = +2 °C
0.988
0.993
Pdh Tj = +7°C
3.22 kW
3.23 kW
COP Tj = +7°C
5.23
3.25
Cdh Tj = +7 °C
0.976
0.985
Pdh Tj = 12°C
1.92 kW
1.82 kW
COP Tj = 12°C
7.72
5.87
Cdh Tj = +12 °C
0.94
0.952
Pdh Tj = Tbiv
5 kW
5 kW
COP Tj = Tbiv
3.86
2.42
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5 kW
5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.86
2.42
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.988
0.993
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1101 kWh
1602 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
131 %
Prated
5 kW
5 kW
SCOP
4.78
3.35
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.42 kW
4.42 kW
COP Tj = -7°C
3.42
2.28
Cdh Tj = -7 °C
0.988
0.992
Pdh Tj = +2°C
2.9 kW
2.76 kW
COP Tj = +2°C
4.38
3.29
Cdh Tj = +2 °C
0.977
0.982
Pdh Tj = +7°C
1.92 kW
1.75 kW
COP Tj = +7°C
6.62
3.87
Cdh Tj = +7 °C
0.948
0.967
Pdh Tj = 12°C
1.92 kW
1.82 kW
COP Tj = 12°C
7.74
6.45
Cdh Tj = +12 °C
0.94
0.947
Pdh Tj = Tbiv
4.42 kW
4.42 kW
COP Tj = Tbiv
3.42
2.28
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.21 kW
4.22 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.11
1.97
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.989
0.993
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.79 kW
0.78 kW
Annual energy consumption Qhe
2161 kWh
3086 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
130 %
COP
3.13
Heating up time
2:46 h:min
Standby power input
36.2 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.77
Heating up time
3:01 h:min
Standby power input
33.3 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l