Certificate holders

Subtype

i-290 0121-0123

Certificate Holder
Advantix S.p.A.
Via San Giuseppe Lavoratore, 24
37040 Arcole Verona
Italy
Registration number
ICIM-PDC-000211
Certification Body
ICIM S.p.A.
Subtype title
i-290 0121-0123
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,700 kg

Certification Date
31.08.2023
Testing basis
V12
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

i-290 0121
Configure model
Model name
i-290 0121
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

21.00 kW

19.60 kW

El input

4.31 kW

6.13 kW

COP

4.87

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

5.26 kW

Cooling capacity

17.40

EER

3.31

EN 14825

+7°C/+12°C

Pdesignc

17.40 kW

SEER

5.27

Pdc Tj = 35°C

17.40 kW

EER Tj = 35°C

3.31

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

12.80 kW

EER Tj = 30°C

4.44

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

9.22 kW

EER Tj = 25°C

5.84

Cdc Tj = 25 °C

0.986

Pdc Tj = 20°C

9.61 kW

EER Tj = 20°C

7.12

Cdc Tj = 20 °C

0.984

Poff

22 W

PTO

0 W

PSB

28 W

PCK

0 W

Annual energy consumption Qce

1981 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

145 %

Prated

20.00 kW

19.00 kW

SCOP

4.75

3.70

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

17.40 kW

16.60 kW

COP Tj = -7°C

2.92

2.12

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

10.60 kW

10.20 kW

COP Tj = +2°C

4.41

3.60

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

9.50 kW

9.20 kW

COP Tj = +7°C

6.90

5.15

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

11.10 kW

10.80 kW

COP Tj = 12°C

8.48

6.47

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

17.40 kW

16.60 kW

COP Tj = Tbiv

2.92

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.80 kW

15.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

69 °C

69 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.20 kW

3.90 kW

Annual energy consumption Qhe

8561 kWh

10466 kWh

i-290 0123
Configure model
Model name
i-290 0123
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

22.80 kW

21.60 kW

El input

4.78 kW

6.79 kW

COP

4.77

3.18

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

5.89 kW

Cooling capacity

18.90

EER

3.21

EN 14825

+7°C/+12°C

Pdesignc

18.90 kW

SEER

5.27

Pdc Tj = 35°C

18.90 kW

EER Tj = 35°C

3.21

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

13.90 kW

EER Tj = 30°C

4.37

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

9.32 kW

EER Tj = 25°C

5.90

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

9.66 kW

EER Tj = 20°C

7.16

Cdc Tj = 20 °C

0.984

Poff

22 W

PTO

0 W

PSB

28 W

PCK

0 W

Annual energy consumption Qce

2151 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

147 %

Prated

21.00 kW

21.00 kW

SCOP

4.72

3.74

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

18.60 kW

18.20 kW

COP Tj = -7°C

2.81

2.09

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

11.30 kW

11.10 kW

COP Tj = +2°C

4.47

3.67

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

9.50 kW

9.20 kW

COP Tj = +7°C

6.81

5.18

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

11.10 kW

10.80 kW

COP Tj = 12°C

8.45

6.62

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

18.60 kW

18.20 kW

COP Tj = Tbiv

2.81

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.00 kW

16.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

69 °C

69 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.00 kW

4.70 kW

Annual energy consumption Qhe

9199 kWh

11363 kWh