1,600 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.31 kW
11.75 kW
El input
2.66 kW
3.94 kW
COP
4.63
2.98
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
133 %
Prated
9.19 kW
8.61 kW
SCOP
4.60
3.39
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
8.13 kW
7.62 kW
COP Tj = -7°C
3.33
2.29
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.96 kW
4.84 kW
COP Tj = +2°C
4.52
3.24
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.24 kW
4.82 kW
COP Tj = +7°C
5.93
4.66
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.55 kW
5.42 kW
COP Tj = 12°C
7.82
6.52
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.13 kW
7.62 kW
COP Tj = Tbiv
3.33
2.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.80 kW
8.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.03
2.10
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
17 W
17 W
PSB
12 W
12 W
PCK
41 W
41 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.39 kW
0.03 kW
Annual energy consumption Qhe
4123 kWh
5252 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.22 kW
11.62 kW
El input
2.61 kW
3.80 kW
COP
4.68
3.06
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
69 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
134 %
Prated
9.06 kW
8.70 kW
SCOP
4.60
3.42
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
8.02 kW
7.69 kW
COP Tj = -7°C
3.28
2.35
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.98 kW
4.83 kW
COP Tj = +2°C
4.50
3.33
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.32 kW
4.94 kW
COP Tj = +7°C
5.99
4.51
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.65 kW
5.52 kW
COP Tj = 12°C
7.93
6.29
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.02 kW
7.69 kW
COP Tj = Tbiv
3.28
2.35
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.05 kW
8.62 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.06
2.14
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
17 W
17 W
PSB
12 W
12 W
PCK
43 W
43 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.01 kW
0.08 kW
Annual energy consumption Qhe
4071 kWh
5260 kWh