Certificate holders

Subtype

Air to Water Heat Pump- R290- 130

Certificate Holder
Guangdong New Energy Technology Development Co., Ltd.
NO.125, Chuangyou Road
511340 Guangdong
China
Registration number
041-K054-06
Certification Body
BRE Global Limited
Subtype title
Air to Water Heat Pump- R290- 130
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,940 kg

Certification Date
12.09.2023
Testing basis
Heat Pump KEYMARK certification Scheme rules v12
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

NE-F130HCR5INVM
Configure model
Model name
NE-F130HCR5INVM
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.09 kW

11.36 kW

El input

2.83 kW

3.87 kW

COP

4.27

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

143 %

Prated

8.79 kW

8.30 kW

SCOP

4.76

3.64

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

7.77 kW

7.34 kW

COP Tj = -7°C

2.99

2.23

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.75 kW

4.47 kW

COP Tj = +2°C

4.56

3.63

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.41 kW

3.16 kW

COP Tj = +7°C

6.78

4.65

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.76 kW

3.81 kW

COP Tj = 12°C

7.99

6.96

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.77 kW

7.34 kW

COP Tj = Tbiv

2.99

2.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.64 kW

7.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.79

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

74 °C

74 °C

Poff

10 W

10 W

PTO

15 W

15 W

PSB

10 W

10 W

PCK

44 W

44 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.15 kW

0.91 kW

Annual energy consumption Qhe

3816 kWh

4703 kWh

NE-F130HCR5TINVM
Configure model
Model name
NE-F130HCR5TINVM
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.06 kW

11.03 kW

El input

2.80 kW

3.76 kW

COP

4.32

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

189 %

143 %

Prated

8.64 kW

8.17 kW

SCOP

4.79

3.66

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

7.64 kW

7.23 kW

COP Tj = -7°C

2.94

2.19

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.81 kW

4.41 kW

COP Tj = +2°C

4.74

3.49

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.46 kW

3.11 kW

COP Tj = +7°C

6.47

5.10

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.98 kW

3.78 kW

COP Tj = 12°C

8.43

7.39

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.64 kW

7.23 kW

COP Tj = Tbiv

2.94

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.42 kW

7.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

14 W

14 W

PSB

10 W

10 W

PCK

44 W

44 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.22 kW

0.94 kW

Annual energy consumption Qhe

3728 kWh

4616 kWh