2,200 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.20 kW
12.00 kW
El input
2.46 kW
3.75 kW
COP
4.95
3.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
54 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
132 %
Prated
12.00 kW
13.00 kW
SCOP
4.68
3.38
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.63 kW
11.55 kW
COP Tj = -7°C
2.79
2.12
Cdh Tj = -7 °C
0.997
0.998
Pdh Tj = +2°C
6.42 kW
6.92 kW
COP Tj = +2°C
4.53
3.16
Cdh Tj = +2 °C
0.992
0.995
Pdh Tj = +7°C
4.99 kW
4.59 kW
COP Tj = +7°C
6.26
4.57
Cdh Tj = +7 °C
0.986
0.989
Pdh Tj = 12°C
6.09 kW
5.91 kW
COP Tj = 12°C
9.88
7.48
Cdh Tj = +12 °C
0.982
0.986
Pdh Tj = Tbiv
10.63 kW
11.55 kW
COP Tj = Tbiv
2.79
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.17 kW
10.99 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.66
1.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
11 W
11 W
PTO
20 W
20 W
PSB
11 W
11 W
PCK
41 W
41 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.83 kW
2.01 kW
Annual energy consumption Qhe
5295 kWh
8013 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.20 kW
14.00 kW
El input
3.02 kW
4.52 kW
COP
4.70
3.10
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
54 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
130 %
Prated
13.00 kW
13.60 kW
SCOP
4.70
3.33
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.45 kW
12.04 kW
COP Tj = -7°C
2.71
2.12
Cdh Tj = -7 °C
0.997
0.998
Pdh Tj = +2°C
7.13 kW
7.32 kW
COP Tj = +2°C
4.46
3.08
Cdh Tj = +2 °C
0.993
0.995
Pdh Tj = +7°C
5.04 kW
4.59 kW
COP Tj = +7°C
6.56
4.57
Cdh Tj = +7 °C
0.986
0.989
Pdh Tj = 12°C
6.05 kW
5.86 kW
COP Tj = 12°C
9.96
7.42
Cdh Tj = +12 °C
0.982
0.986
Pdh Tj = Tbiv
11.45 kW
12.04 kW
COP Tj = Tbiv
2.71
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.61 kW
11.82 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.58
1.74
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
11 W
11 W
PTO
20 W
20 W
PSB
11 W
11 W
PCK
41 W
41 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.39 kW
1.78 kW
Annual energy consumption Qhe
5722 kWh
8472 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.00 kW
16.00 kW
El input
3.52 kW
5.33 kW
COP
4.55
3.00
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
54 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
130 %
Prated
13.00 kW
13.70 kW
SCOP
4.65
3.33
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.41 kW
12.06 kW
COP Tj = -7°C
2.69
2.08
Cdh Tj = -7 °C
0.997
0.998
Pdh Tj = +2°C
7.16 kW
7.39 kW
COP Tj = +2°C
4.45
3.13
Cdh Tj = +2 °C
0.993
0.995
Pdh Tj = +7°C
4.96 kW
4.60 kW
COP Tj = +7°C
6.42
4.55
Cdh Tj = +7 °C
0.986
0.989
Pdh Tj = 12°C
6.09 kW
5.89 kW
COP Tj = 12°C
9.92
7.44
Cdh Tj = +12 °C
0.982
0.986
Pdh Tj = Tbiv
11.41 kW
12.06 kW
COP Tj = Tbiv
2.69
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.57 kW
11.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.55
1.73
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
11 W
11 W
PTO
20 W
20 W
PSB
11 W
11 W
PCK
41 W
41 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.43 kW
1.90 kW
Annual energy consumption Qhe
5774 kWh
8532 kWh