Certificate holders

Subtype

Daikin Altherma 3 R MT ECH2O 08-12 kW (500L)

Certificate Holder
DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium
Registration number
011-1W0658
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Daikin Altherma 3 R MT ECH2O 08-12 kW (500L)
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

3,250 kg

Certification Date
01.08.2023
Testing basis
HP KEYMARK certification scheme rules V12
Generate PDF Export model CSV
  • Number of models 12

Models

ERRA08EV3 / ELSH(B)12P50E
Configure model
Model name
ERRA08EV3 / ELSH(B)12P50E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.62 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.15 kW

Cooling capacity

6.81

EER

3.17

EN 14825

+7°C/+12°C

Pdesignc

6.5 kW

SEER

5.38

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.17

Pdc Tj = 30°C

5 kW

EER Tj = 30°C

4.37

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.58

Cdc Tj = 25 °C

0.94

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

8

Cdc Tj = 20 °C

0.91

Poff

25 W

PTO

3 W

PSB

25 W

PCK

0 W

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.7 dB(A)

44.7 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

130 %

Prated

8.3 kW

12.5 kW

SCOP

4.69

3.34

Tbiv

-7 °C

-2 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.1

2.26

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.4 kW

6.8 kW

COP Tj = +2°C

4.76

3.39

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

4.3 kW

4.5 kW

COP Tj = +7°C

6.14

4.9

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6.6 kW

5.2 kW

COP Tj = 12°C

7.84

6.02

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

7.5 kW

8.5 kW

COP Tj = Tbiv

3.1

2.81

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

6.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.8

1.97

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

5.6 kW

Annual energy consumption Qhe

3659 kWh

7742 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

131.5 %

COP

3.19

Heating up time

3:28 h:min

Standby power input

32.7 W

Reference hot water temperature

44.7 °C

Mixed water at 40°C

260 l

ERRA08EW1 / ELSH(B)12P50E
Configure model
Model name
ERRA08EW1 / ELSH(B)12P50E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.1

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.08 kW

Cooling capacity

6.47

EER

3.28

EN 14825

+7°C/+12°C

Pdesignc

6.5 kW

SEER

5.42

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.28

Pdc Tj = 30°C

5 kW

EER Tj = 30°C

4.52

Cdc Tj = 30 °C

0.97

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.66

Cdc Tj = 25 °C

0.94

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

7.98

Cdc Tj = 20 °C

0.91

Poff

31 W

PTO

0 W

PSB

31 W

PCK

0 W

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.7 dB(A)

44.7 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

134 %

Prated

8.3 kW

12.5 kW

SCOP

4.81

3.42

Tbiv

-7 °C

-2 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.2

2.34

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.4 kW

6.8 kW

COP Tj = +2°C

4.93

3.5

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

4.3 kW

4.5 kW

COP Tj = +7°C

6.37

5.07

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6.6 kW

5.2 kW

COP Tj = 12°C

8.13

6.23

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

7.5 kW

8.5 kW

COP Tj = Tbiv

3.2

2.9

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

6.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.9

2.04

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

5.6 kW

Annual energy consumption Qhe

3561 kWh

7541 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

135.7 %

COP

3.29

Heating up time

3:28 h:min

Standby power input

32.5 W

Reference hot water temperature

44.7 °C

Mixed water at 40°C

260 l

ERRA10EV3 / ELSH(B)12P50E
Configure model
Model name
ERRA10EV3 / ELSH(B)12P50E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.62 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.66 kW

Cooling capacity

7.97

EER

3

EN 14825

+7°C/+12°C

Pdesignc

7.5 kW

SEER

5.34

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.28

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.31

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.37

Cdc Tj = 20 °C

0.91

Poff

25 W

PTO

3 W

PSB

25 W

PCK

0 W

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.7 dB(A)

44.7 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

131 %

Prated

8.3 kW

12.5 kW

SCOP

4.71

3.34

Tbiv

-10 °C

-2 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.1

2.26

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.4 kW

6.8 kW

COP Tj = +2°C

4.76

3.39

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

4.3 kW

4.5 kW

COP Tj = +7°C

6.14

4.9

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6.6 kW

5.2 kW

COP Tj = 12°C

7.84

6.02

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

8.1 kW

8.5 kW

COP Tj = Tbiv

2.77

2.81

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

2

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

4.3 kW

Annual energy consumption Qhe

3637 kWh

7723 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

131.5 %

COP

3.19

Heating up time

3:28 h:min

Standby power input

32.7 W

Reference hot water temperature

44.7 °C

Mixed water at 40°C

260 l

ERRA10EW1 / ELSH(B)12P50E
Configure model
Model name
ERRA10EW1 / ELSH(B)12P50E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.1

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.57 kW

Cooling capacity

6.47

EER

3.1

EN 14825

+7°C/+12°C

Pdesignc

7.5 kW

SEER

5.41

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3.1

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.43

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.47

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.35

Cdc Tj = 20 °C

0.91

Poff

31 W

PTO

0 W

PSB

31 W

PCK

0 W

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.7 dB(A)

44.7 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

134 %

Prated

8.3 kW

12.5 kW

SCOP

4.84

3.43

Tbiv

-10 °C

-2 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.2

2.34

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.4 kW

6.8 kW

COP Tj = +2°C

4.93

3.5

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

4.3 kW

4.5 kW

COP Tj = +7°C

6.37

5.07

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6.6 kW

5.2 kW

COP Tj = 12°C

8.13

6.23

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

8.1 kW

8.5 kW

COP Tj = Tbiv

2.86

2.9

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.06

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

4.3 kW

Annual energy consumption Qhe

3539 kWh

7522 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

135.7 %

COP

3.29

Heating up time

3:28 h:min

Standby power input

32.5 W

Reference hot water temperature

44.7 °C

Mixed water at 40°C

260 l

ERRA12EV3 / ELSH(B)12P50E
Configure model
Model name
ERRA12EV3 / ELSH(B)12P50E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.62 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.96 kW

Cooling capacity

8.62

EER

2.91

EN 14825

+7°C/+12°C

Pdesignc

8.5 kW

SEER

5.31

Pdc Tj = 35°C

8.62 kW

EER Tj = 35°C

2.91

Pdc Tj = 30°C

6.68 kW

EER Tj = 30°C

4.17

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

4.04 kW

EER Tj = 25°C

6.13

Cdc Tj = 25 °C

0.96

Pdc Tj = 20°C

2.69 kW

EER Tj = 20°C

8.75

Cdc Tj = 20 °C

0.91

Poff

25 W

PTO

3 W

PSB

25 W

PCK

0 W

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.7 dB(A)

44.7 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

135 %

Prated

8.3 kW

12.5 kW

SCOP

4.71

3.44

Tbiv

-10 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.1

2.26

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.4 kW

6.8 kW

COP Tj = +2°C

4.76

3.39

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

4.3 kW

4.5 kW

COP Tj = +7°C

6.14

4.9

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6.6 kW

5.2 kW

COP Tj = 12°C

7.84

6.02

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

8.1 kW

10 kW

COP Tj = Tbiv

2.77

2.41

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

2

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

4.3 kW

Annual energy consumption Qhe

3637 kWh

7510 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

131.5 %

COP

3.19

Heating up time

3:28 h:min

Standby power input

32.7 W

Reference hot water temperature

44.7 °C

Mixed water at 40°C

260 l

ERRA12EW1 / ELSH(B)12P50E
Configure model
Model name
ERRA12EW1 / ELSH(B)12P50E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.1

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.86 kW

Cooling capacity

6.47

EER

3.01

EN 14825

+7°C/+12°C

Pdesignc

8.5 kW

SEER

5.41

Pdc Tj = 35°C

8.62 kW

EER Tj = 35°C

3.01

Pdc Tj = 30°C

6.68 kW

EER Tj = 30°C

4.32

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

4.04 kW

EER Tj = 25°C

6.34

Cdc Tj = 25 °C

0.96

Pdc Tj = 20°C

2.69 kW

EER Tj = 20°C

8.72

Cdc Tj = 20 °C

0.91

Poff

31 W

PTO

0 W

PSB

31 W

PCK

0 W

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.7 dB(A)

44.7 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

138 %

Prated

8.3 kW

12.5 kW

SCOP

4.84

3.53

Tbiv

-10 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.2

2.34

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.4 kW

6.8 kW

COP Tj = +2°C

4.93

3.5

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

4.3 kW

4.5 kW

COP Tj = +7°C

6.37

5.07

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6.6 kW

5.2 kW

COP Tj = 12°C

8.13

6.23

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

8.1 kW

10 kW

COP Tj = Tbiv

2.86

2.48

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.06

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

4.3 kW

Annual energy consumption Qhe

3539 kWh

7309 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

135.7 %

COP

3.29

Heating up time

3:28 h:min

Standby power input

32.5 W

Reference hot water temperature

44.7 °C

Mixed water at 40°C

260 l

ERRA08EV3 / ELSX(B)12P50E
Configure model
Model name
ERRA08EV3 / ELSX(B)12P50E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.62 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.15 kW

Cooling capacity

6.81

EER

3.17

EN 14825

+7°C/+12°C

Pdesignc

6.5 kW

SEER

5.38

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.17

Pdc Tj = 30°C

5 kW

EER Tj = 30°C

4.37

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.58

Cdc Tj = 25 °C

0.94

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

8

Cdc Tj = 20 °C

0.91

Poff

25 W

PTO

3 W

PSB

25 W

PCK

0 W

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.7 dB(A)

44.7 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

132 %

Prated

8.3 kW

12.5 kW

SCOP

4.79

3.37

Tbiv

-7 °C

-2 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.1

2.26

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.4 kW

6.8 kW

COP Tj = +2°C

4.76

3.39

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

4.3 kW

4.5 kW

COP Tj = +7°C

6.14

4.9

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6.6 kW

5.2 kW

COP Tj = 12°C

7.84

6.02

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

7.5 kW

8.5 kW

COP Tj = Tbiv

3.1

2.81

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

6.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.8

1.97

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

5.6 kW

Annual energy consumption Qhe

3582 kWh

7664 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

131.5 %

COP

3.19

Heating up time

3:28 h:min

Standby power input

32.7 W

Reference hot water temperature

44.7 °C

Mixed water at 40°C

260 l

ERRA08EW1 / ELSX(B)12P50E
Configure model
Model name
ERRA08EW1 / ELSX(B)12P50E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.1

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.08 kW

Cooling capacity

6.47

EER

3.28

EN 14825

+7°C/+12°C

Pdesignc

6.5 kW

SEER

5.42

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.28

Pdc Tj = 30°C

5 kW

EER Tj = 30°C

4.52

Cdc Tj = 30 °C

0.97

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.66

Cdc Tj = 25 °C

0.94

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

7.98

Cdc Tj = 20 °C

0.91

Poff

31 W

PTO

0 W

PSB

31 W

PCK

0 W

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.7 dB(A)

44.7 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

136 %

Prated

8.3 kW

12.5 kW

SCOP

4.95

3.47

Tbiv

-7 °C

-2 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.2

2.34

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.4 kW

6.8 kW

COP Tj = +2°C

4.93

3.5

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

4.3 kW

4.5 kW

COP Tj = +7°C

6.37

5.07

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6.6 kW

5.2 kW

COP Tj = 12°C

8.13

6.23

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

7.5 kW

8.5 kW

COP Tj = Tbiv

3.2

2.9

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

6.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.9

2.04

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

5.6 kW

Annual energy consumption Qhe

3462 kWh

7442 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

135.7 %

COP

3.29

Heating up time

3:28 h:min

Standby power input

32.5 W

Reference hot water temperature

44.7 °C

Mixed water at 40°C

260 l

ERRA10EV3 / ELSX(B)12P50E
Configure model
Model name
ERRA10EV3 / ELSX(B)12P50E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.62 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.66 kW

Cooling capacity

7.97

EER

3

EN 14825

+7°C/+12°C

Pdesignc

7.5 kW

SEER

5.34

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.28

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.31

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.37

Cdc Tj = 20 °C

0.91

Poff

25 W

PTO

3 W

PSB

25 W

PCK

0 W

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.7 dB(A)

44.7 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

132 %

Prated

8.3 kW

12.5 kW

SCOP

4.82

3.38

Tbiv

-10 °C

-2 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.1

2.26

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.4 kW

6.8 kW

COP Tj = +2°C

4.76

3.39

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

4.3 kW

4.5 kW

COP Tj = +7°C

6.14

4.9

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6.6 kW

5.2 kW

COP Tj = 12°C

7.84

6.02

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

8.1 kW

8.5 kW

COP Tj = Tbiv

2.77

2.81

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

2

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

4.3 kW

Annual energy consumption Qhe

3560 kWh

7645 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

131.5 %

COP

3.19

Heating up time

3:28 h:min

Standby power input

32.7 W

Reference hot water temperature

44.7 °C

Mixed water at 40°C

260 l

ERRA10EW1 / ELSX(B)12P50E
Configure model
Model name
ERRA10EW1 / ELSX(B)12P50E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.1

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.57 kW

Cooling capacity

6.47

EER

3.1

EN 14825

+7°C/+12°C

Pdesignc

7.5 kW

SEER

5.41

Pdc Tj = 35°C

7.97 kW

EER Tj = 35°C

3.1

Pdc Tj = 30°C

5.76 kW

EER Tj = 30°C

4.43

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

3.63 kW

EER Tj = 25°C

6.47

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

2.63 kW

EER Tj = 20°C

8.35

Cdc Tj = 20 °C

0.91

Poff

31 W

PTO

0 W

PSB

31 W

PCK

0 W

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.7 dB(A)

44.7 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

136 %

Prated

8.30 kW

12.50 kW

SCOP

4.98

3.48

Tbiv

-10 °C

-2 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.50 kW

7.60 kW

COP Tj = -7°C

3.20

2.34

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.40 kW

6.80 kW

COP Tj = +2°C

4.93

3.50

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

4.30 kW

4.50 kW

COP Tj = +7°C

6.37

5.07

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

6.60 kW

5.20 kW

COP Tj = 12°C

8.13

6.23

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

8.10 kW

8.50 kW

COP Tj = Tbiv

2.86

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.10 kW

8.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

4.30 kW

Annual energy consumption Qhe

3440 kWh

7423 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

135.7 %

COP

3.29

Heating up time

3:28 h:min

Standby power input

32.5 W

Reference hot water temperature

44.7 °C

Mixed water at 40°C

260 l

ERRA12EV3 / ELSX(B)12P50E
Configure model
Model name
ERRA12EV3 / ELSX(B)12P50E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.62 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.96 kW

Cooling capacity

8.62

EER

2.91

EN 14825

+7°C/+12°C

Pdesignc

8.5 kW

SEER

5.31

Pdc Tj = 35°C

8.62 kW

EER Tj = 35°C

2.91

Pdc Tj = 30°C

6.68 kW

EER Tj = 30°C

4.17

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

4.04 kW

EER Tj = 25°C

6.13

Cdc Tj = 25 °C

0.96

Pdc Tj = 20°C

2.69 kW

EER Tj = 20°C

8.75

Cdc Tj = 20 °C

0.91

Poff

25 W

PTO

3 W

PSB

25 W

PCK

0 W

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.7 dB(A)

44.7 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

136 %

Prated

8.3 kW

12.5 kW

SCOP

4.82

3.47

Tbiv

-10 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.1

2.26

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.4 kW

6.8 kW

COP Tj = +2°C

4.76

3.39

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

4.3 kW

4.5 kW

COP Tj = +7°C

6.14

4.9

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6.6 kW

5.2 kW

COP Tj = 12°C

7.84

6.02

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

8.1 kW

10 kW

COP Tj = Tbiv

2.77

2.41

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

2

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

4.3 kW

Annual energy consumption Qhe

3560 kWh

7433 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

131.5 %

COP

3.19

Heating up time

3:28 h:min

Standby power input

32.7 W

Reference hot water temperature

44.7 °C

Mixed water at 40°C

260 l

ERRA12EW1 / ELSX(B)12P50E
Configure model
Model name
ERRA12EW1 / ELSX(B)12P50E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.1

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.86 kW

Cooling capacity

6.47

EER

3.01

EN 14825

+7°C/+12°C

Pdesignc

8.5 kW

SEER

5.41

Pdc Tj = 35°C

8.62 kW

EER Tj = 35°C

3.01

Pdc Tj = 30°C

6.68 kW

EER Tj = 30°C

4.32

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

4.04 kW

EER Tj = 25°C

6.34

Cdc Tj = 25 °C

0.96

Pdc Tj = 20°C

2.69 kW

EER Tj = 20°C

8.72

Cdc Tj = 20 °C

0.91

Poff

31 W

PTO

0 W

PSB

31 W

PCK

0 W

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.7 dB(A)

44.7 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

140 %

Prated

8.3 kW

12.5 kW

SCOP

4.98

3.58

Tbiv

-10 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.2

2.34

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.4 kW

6.8 kW

COP Tj = +2°C

4.93

3.5

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

4.3 kW

4.5 kW

COP Tj = +7°C

6.37

5.07

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6.6 kW

5.2 kW

COP Tj = 12°C

8.13

6.23

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

8.1 kW

10 kW

COP Tj = Tbiv

2.86

2.48

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.1 kW

8.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.06

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

4.3 kW

Annual energy consumption Qhe

3440 kWh

7210 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

135.7 %

COP

3.29

Heating up time

3:28 h:min

Standby power input

32.5 W

Reference hot water temperature

44.7 °C

Mixed water at 40°C

260 l