2,800 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.85 kW
15.65 kW
El input
2.11 kW
4.79 kW
COP
5.13
3.26
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
63 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
139 %
Prated
12.08 kW
12.35 kW
SCOP
4.55
3.54
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.68 kW
10.93 kW
COP Tj = -7°C
2.87
2.31
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.82 kW
6.89 kW
COP Tj = +2°C
4.67
3.62
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.22 kW
7.89 kW
COP Tj = +7°C
6.28
4.68
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
9.22 kW
9.01 kW
COP Tj = 12°C
8.17
6.22
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.68 kW
10.93 kW
COP Tj = Tbiv
2.87
2.31
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.15 kW
11.34 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.65
2.10
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
16 W
16 W
PTO
19 W
19 W
PSB
16 W
16 W
PCK
47 W
47 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.92 kW
1.01 kW
Annual energy consumption Qhe
5482 kWh
7200 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
11.46 kW
16.38 kW
El input
2.23 kW
5.02 kW
COP
5.13
3.26
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
139 %
Prated
12.58 kW
13.52 kW
SCOP
4.59
3.56
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.13 kW
11.96 kW
COP Tj = -7°C
2.69
2.31
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.10 kW
7.57 kW
COP Tj = +2°C
4.77
3.58
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.54 kW
8.00 kW
COP Tj = +7°C
6.36
4.75
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
9.59 kW
9.15 kW
COP Tj = 12°C
8.40
6.32
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.13 kW
11.96 kW
COP Tj = Tbiv
2.69
2.31
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.63 kW
12.26 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
2.07
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
17 W
17 W
PTO
18 W
18 W
PSB
17 W
17 W
PCK
34 W
34 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.95 kW
1.26 kW
Annual energy consumption Qhe
5658 kWh
7849 kWh