0,850 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.00 kW
10.32 kW
El input
2.01 kW
3.13 kW
COP
4.99
3.30
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
56 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
194 %
148 %
Prated
9.29 kW
9.24 kW
SCOP
4.92
3.78
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.22 kW
8.17 kW
COP Tj = -7°C
3.17
2.58
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
5.04 kW
4.98 kW
COP Tj = +2°C
4.85
3.62
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.72 kW
5.56 kW
COP Tj = +7°C
6.11
4.67
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
6.23 kW
6.08 kW
COP Tj = 12°C
7.59
6.16
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
8.22 kW
8.17 kW
COP Tj = Tbiv
3.17
2.58
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.39 kW
8.95 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.85
2.54
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
64 W
64 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.29 kW
Annual energy consumption Qhe
3903 kWh
5052 kWh