Certificate holders

Subtype

BERETTA HYDRO UNIT P 012, HYDRO UNIT P 014, HYDRO UNIT P 012T, HYDRO UNIT P 014T

Certificate Holder
Riello S.p.A.
Via Ing. Pilade Riello 7
37045 Legnago (VR)
Italy
Registration number
011-1W0630
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
BERETTA HYDRO UNIT P 012, HYDRO UNIT P 014, HYDRO UNIT P 012T, HYDRO UNIT P 014T
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,070 kg

Certification Date
26.06.2023
Testing basis
HP KEYMARK Certification Scheme Rules Rev. 12
Generate PDF Export model CSV
  • Number of models 4

Models

BERETTA HYDRO UNIT P 012
Configure model
Model name
BERETTA HYDRO UNIT P 012
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.40 kW

10.95 kW

El input

2.50 kW

3.54 kW

COP

4.55

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.18 kW

Cooling capacity

9.70

EER

3.05

EN 14825

+7°C/+12°C

Pdesignc

9.70 kW

SEER

5.34

Pdc Tj = 35°C

9.70 kW

EER Tj = 35°C

3.05

Cdc Tj = 35 °C

 

Pdc Tj = 30°C

7.15 kW

EER Tj = 30°C

4.49

Cdc Tj = 30 °C

 

Pdc Tj = 25°C

4.59 kW

EER Tj = 25°C

5.96

Cdc Tj = 25 °C

 

Pdc Tj = 20°C

3.60 kW

EER Tj = 20°C

8.31

Cdc Tj = 20 °C

0.900

Poff

10 W

PTO

15 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

5820 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

52 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

131 %

Prated

9.35 kW

9.33 kW

SCOP

4.74

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.27 kW

8.25 kW

COP Tj = -7°C

2.74

1.97

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

5.03 kW

5.02 kW

COP Tj = +2°C

4.65

3.17

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

4.86 kW

3.23 kW

COP Tj = +7°C

6.55

4.76

Cdh Tj = +7 °C

0.973

0.976

Pdh Tj = 12°C

3.81 kW

3.52 kW

COP Tj = 12°C

9.06

6.45

Cdh Tj = +12 °C

0.952

0.973

Pdh Tj = Tbiv

8.27 kW

8.25 kW

COP Tj = Tbiv

2.74

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.66 kW

7.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

15 W

15 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

1.69 kW

1.68 kW

Annual energy consumption Qhe

4068 kWh

5743 kWh

BERETTA HYDRO UNIT P 012T
Configure model
Model name
BERETTA HYDRO UNIT P 012T
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.40 kW

10.95 kW

El input

2.45 kW

3.48 kW

COP

4.65

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.13 kW

Cooling capacity

9.70

EER

3.10

EN 14825

+7°C/+12°C

Pdesignc

9.70 kW

SEER

5.34

Pdc Tj = 35°C

9.70 kW

EER Tj = 35°C

3.10

Cdc Tj = 35 °C

 

Pdc Tj = 30°C

7.15 kW

EER Tj = 30°C

4.49

Cdc Tj = 30 °C

 

Pdc Tj = 25°C

4.59 kW

EER Tj = 25°C

5.96

Cdc Tj = 25 °C

 

Pdc Tj = 20°C

3.60 kW

EER Tj = 20°C

8.22

Cdc Tj = 20 °C

0.900

Poff

10 W

PTO

15 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

5820 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

52 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

131 %

Prated

9.35 kW

9.33 kW

SCOP

4.74

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.27 kW

8.25 kW

COP Tj = -7°C

2.74

1.97

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

5.03 kW

5.02 kW

COP Tj = +2°C

4.65

3.17

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

4.86 kW

3.23 kW

COP Tj = +7°C

6.55

4.76

Cdh Tj = +7 °C

0.973

0.976

Pdh Tj = 12°C

3.81 kW

3.52 kW

COP Tj = 12°C

9.06

6.45

Cdh Tj = +12 °C

0.952

0.973

Pdh Tj = Tbiv

8.27 kW

8.25 kW

COP Tj = Tbiv

2.74

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.66 kW

7.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

15 W

15 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

1.69 kW

1.68 kW

Annual energy consumption Qhe

4068 kWh

5743 kWh

BERETTA HYDRO UNIT P 014
Configure model
Model name
BERETTA HYDRO UNIT P 014
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

13.80 kW

13.25 kW

El input

3.21 kW

4.57 kW

COP

4.30

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.63 kW

Cooling capacity

10.70

EER

2.95

EN 14825

+7°C/+12°C

Pdesignc

10.70 kW

SEER

5.15

Pdc Tj = 35°C

10.70 kW

EER Tj = 35°C

2.95

Cdc Tj = 35 °C

 

Pdc Tj = 30°C

7.88 kW

EER Tj = 30°C

4.07

Cdc Tj = 30 °C

 

Pdc Tj = 25°C

5.07 kW

EER Tj = 25°C

5.91

Cdc Tj = 25 °C

 

Pdc Tj = 20°C

3.63 kW

EER Tj = 20°C

8.04

Cdc Tj = 20 °C

0.900

Poff

10 W

PTO

15 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

6420 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

52 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

131 %

Prated

9.35 kW

9.33 kW

SCOP

4.74

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.27 kW

8.25 kW

COP Tj = -7°C

2.74

1.97

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

5.03 kW

5.02 kW

COP Tj = +2°C

4.65

3.17

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

4.86 kW

3.23 kW

COP Tj = +7°C

6.55

4.76

Cdh Tj = +7 °C

0.973

0.976

Pdh Tj = 12°C

3.81 kW

3.52 kW

COP Tj = 12°C

9.06

6.45

Cdh Tj = +12 °C

0.952

0.973

Pdh Tj = Tbiv

8.27 kW

8.25 kW

COP Tj = Tbiv

2.74

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.66 kW

7.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

15 W

15 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

1.69 kW

1.68 kW

Annual energy consumption Qhe

4068 kWh

5743 kWh

BERETTA HYDRO UNIT P 014T
Configure model
Model name
BERETTA HYDRO UNIT P 014T
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

13.80 kW

13.25 kW

El input

3.14 kW

4.49 kW

COP

4.40

2.95

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.57 kW

Cooling capacity

10.70

EER

3.00

EN 14825

+7°C/+12°C

Pdesignc

10.70 kW

SEER

5.15

Pdc Tj = 35°C

10.70 kW

EER Tj = 35°C

3.00

Cdc Tj = 35 °C

 

Pdc Tj = 30°C

7.88 kW

EER Tj = 30°C

4.07

Cdc Tj = 30 °C

 

Pdc Tj = 25°C

5.07 kW

EER Tj = 25°C

5.91

Cdc Tj = 25 °C

 

Pdc Tj = 20°C

3.63 kW

EER Tj = 20°C

7.96

Cdc Tj = 20 °C

0.900

Poff

10 W

PTO

15 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

6420 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

52 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

131 %

Prated

9.35 kW

9.33 kW

SCOP

4.74

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.27 kW

8.25 kW

COP Tj = -7°C

2.74

1.97

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

5.03 kW

5.02 kW

COP Tj = +2°C

4.65

3.17

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

4.86 kW

3.23 kW

COP Tj = +7°C

6.55

4.76

Cdh Tj = +7 °C

0.973

0.976

Pdh Tj = 12°C

3.81 kW

3.52 kW

COP Tj = 12°C

9.06

6.45

Cdh Tj = +12 °C

0.952

0.973

Pdh Tj = Tbiv

8.27 kW

8.25 kW

COP Tj = Tbiv

2.74

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.66 kW

7.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

15 W

15 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

1.69 kW

1.68 kW

Annual energy consumption Qhe

4068 kWh

5743 kWh