Certificate holders

Subtype

RIELLO NXHP 012, NXHP 014, NXHP 012T, NXHP 014T

Certificate Holder
Riello S.p.A.
Via Ing. Pilade Riello 7
37045 Legnago (VR)
Italy
Registration number
011-1W0620
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
RIELLO NXHP 012, NXHP 014, NXHP 012T, NXHP 014T
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,070 kg

Certification Date
26.06.2023
Testing basis
HP KEYMARK Certification Scheme Rules Rev. 12
Generate PDF Export model CSV
  • Number of models 4

Models

RIELLO NXHP 012
Configure model
Model name
RIELLO NXHP 012
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.40 kW

10.95 kW

El input

2.50 kW

3.54 kW

COP

4.55

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.18 kW

Cooling capacity

9.70

EER

3.05

EN 14825

+7°C/+12°C

Pdesignc

9.70 kW

SEER

5.34

Pdc Tj = 35°C

9.70 kW

EER Tj = 35°C

3.05

Cdc Tj = 35 °C

 

Pdc Tj = 30°C

7.15 kW

EER Tj = 30°C

4.49

Cdc Tj = 30 °C

 

Pdc Tj = 25°C

4.59 kW

EER Tj = 25°C

5.96

Cdc Tj = 25 °C

 

Pdc Tj = 20°C

3.60 kW

EER Tj = 20°C

8.31

Cdc Tj = 20 °C

0.900

Poff

10 W

PTO

15 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

5820 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

52 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

131 %

Prated

9.35 kW

9.33 kW

SCOP

4.74

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.27 kW

8.25 kW

COP Tj = -7°C

2.74

1.97

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

5.03 kW

5.02 kW

COP Tj = +2°C

4.65

3.17

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

4.86 kW

3.23 kW

COP Tj = +7°C

6.55

4.76

Cdh Tj = +7 °C

0.973

0.976

Pdh Tj = 12°C

3.81 kW

3.52 kW

COP Tj = 12°C

9.06

6.45

Cdh Tj = +12 °C

0.952

0.973

Pdh Tj = Tbiv

8.27 kW

8.25 kW

COP Tj = Tbiv

2.74

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.66 kW

7.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

15 W

15 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

1.69 kW

1.68 kW

Annual energy consumption Qhe

4068 kWh

5743 kWh

RIELLO NXHP 012T
Configure model
Model name
RIELLO NXHP 012T
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.40 kW

10.95 kW

El input

2.45 kW

3.48 kW

COP

4.65

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.13 kW

Cooling capacity

9.70

EER

3.10

EN 14825

+7°C/+12°C

Pdesignc

9.70 kW

SEER

5.34

Pdc Tj = 35°C

9.70 kW

EER Tj = 35°C

3.10

Cdc Tj = 35 °C

 

Pdc Tj = 30°C

7.15 kW

EER Tj = 30°C

4.49

Cdc Tj = 30 °C

 

Pdc Tj = 25°C

4.59 kW

EER Tj = 25°C

5.96

Cdc Tj = 25 °C

 

Pdc Tj = 20°C

3.60 kW

EER Tj = 20°C

8.22

Cdc Tj = 20 °C

0.900

Poff

10 W

PTO

15 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

5820 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

52 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

131 %

Prated

9.35 kW

9.33 kW

SCOP

4.74

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.27 kW

8.25 kW

COP Tj = -7°C

2.74

1.97

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

5.03 kW

5.02 kW

COP Tj = +2°C

4.65

3.17

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

4.86 kW

3.23 kW

COP Tj = +7°C

6.55

4.76

Cdh Tj = +7 °C

0.973

0.976

Pdh Tj = 12°C

3.81 kW

3.52 kW

COP Tj = 12°C

9.06

6.45

Cdh Tj = +12 °C

0.952

0.973

Pdh Tj = Tbiv

8.27 kW

8.25 kW

COP Tj = Tbiv

2.74

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.66 kW

7.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

15 W

15 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

1.69 kW

1.68 kW

Annual energy consumption Qhe

4068 kWh

5743 kWh

RIELLO NXHP 014
Configure model
Model name
RIELLO NXHP 014
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

13.80 kW

13.25 kW

El input

3.21 kW

4.57 kW

COP

4.30

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.63 kW

Cooling capacity

10.70

EER

2.95

EN 14825

+7°C/+12°C

Pdesignc

10.70 kW

SEER

5.15

Pdc Tj = 35°C

10.70 kW

EER Tj = 35°C

2.95

Cdc Tj = 35 °C

 

Pdc Tj = 30°C

7.88 kW

EER Tj = 30°C

4.07

Cdc Tj = 30 °C

 

Pdc Tj = 25°C

5.07 kW

EER Tj = 25°C

5.91

Cdc Tj = 25 °C

 

Pdc Tj = 20°C

3.63 kW

EER Tj = 20°C

8.04

Cdc Tj = 20 °C

0.900

Poff

10 W

PTO

15 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

6420 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

52 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

131 %

Prated

9.35 kW

9.33 kW

SCOP

4.74

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.27 kW

8.25 kW

COP Tj = -7°C

2.74

1.97

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

5.03 kW

5.02 kW

COP Tj = +2°C

4.65

3.17

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

4.86 kW

3.23 kW

COP Tj = +7°C

6.55

4.76

Cdh Tj = +7 °C

0.973

0.976

Pdh Tj = 12°C

3.81 kW

3.52 kW

COP Tj = 12°C

9.06

6.45

Cdh Tj = +12 °C

0.952

0.973

Pdh Tj = Tbiv

8.27 kW

8.25 kW

COP Tj = Tbiv

2.74

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.66 kW

7.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

15 W

15 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

1.69 kW

1.68 kW

Annual energy consumption Qhe

4068 kWh

5743 kWh

RIELLO NXHP 014T
Configure model
Model name
RIELLO NXHP 014T
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

13.80 kW

13.25 kW

El input

3.14 kW

4.49 kW

COP

4.40

2.95

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.57 kW

Cooling capacity

10.70

EER

3.00

EN 14825

+7°C/+12°C

Pdesignc

10.70 kW

SEER

5.15

Pdc Tj = 35°C

10.70 kW

EER Tj = 35°C

3.00

Cdc Tj = 35 °C

 

Pdc Tj = 30°C

7.88 kW

EER Tj = 30°C

4.07

Cdc Tj = 30 °C

 

Pdc Tj = 25°C

5.07 kW

EER Tj = 25°C

5.91

Cdc Tj = 25 °C

 

Pdc Tj = 20°C

3.63 kW

EER Tj = 20°C

7.96

Cdc Tj = 20 °C

0.900

Poff

10 W

PTO

15 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

6420 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

52 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

131 %

Prated

9.35 kW

9.33 kW

SCOP

4.74

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.27 kW

8.25 kW

COP Tj = -7°C

2.74

1.97

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

5.03 kW

5.02 kW

COP Tj = +2°C

4.65

3.17

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

4.86 kW

3.23 kW

COP Tj = +7°C

6.55

4.76

Cdh Tj = +7 °C

0.973

0.976

Pdh Tj = 12°C

3.81 kW

3.52 kW

COP Tj = 12°C

9.06

6.45

Cdh Tj = +12 °C

0.952

0.973

Pdh Tj = Tbiv

8.27 kW

8.25 kW

COP Tj = Tbiv

2.74

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.66 kW

7.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

15 W

15 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

1.69 kW

1.68 kW

Annual energy consumption Qhe

4068 kWh

5743 kWh