RIELLO NXHP 010

Certificate Holder
Riello S.p.A.
Via Ing. Pilade Riello 7
37045 Legnago (VR)
Italy
Registration number
011-1W0619
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
RIELLO NXHP 010
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,760 kg

Certification Date
26.06.2023
Testing basis
HP KEYMARK Certification Scheme Rules Rev. 12
Generate PDF Export model CSV
  • Number of models 1

Models

RIELLO NXHP 010
Configure model
Model name
RIELLO NXHP 010
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.60 kW

9.40 kW

El input

2.21 kW

3.19 kW

COP

4.35

2.95

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.55 kW

Cooling capacity

7.40

EER

2.90

EN 14825

+7°C/+12°C

Pdesignc

7.40 kW

SEER

5.15

Pdc Tj = 35°C

7.40 kW

EER Tj = 35°C

2.90

Cdc Tj = 35 °C

 

Pdc Tj = 30°C

5.45 kW

EER Tj = 30°C

4.23

Cdc Tj = 30 °C

 

Pdc Tj = 25°C

3.51 kW

EER Tj = 25°C

6.10

Cdc Tj = 25 °C

 

Pdc Tj = 20°C

3.02 kW

EER Tj = 20°C

7.54

Cdc Tj = 20 °C

0.963

Poff

10 W

PTO

15 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

4440 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

49 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

131 %

Prated

6.43 kW

6.45 kW

SCOP

4.69

3.34

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.69 kW

5.71 kW

COP Tj = -7°C

2.68

1.90

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

3.46 kW

3.48 kW

COP Tj = +2°C

4.60

3.12

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

2.80 kW

2.68 kW

COP Tj = +7°C

6.63

4.97

Cdh Tj = +7 °C

0.964

0.972

Pdh Tj = 12°C

3.23 kW

3.16 kW

COP Tj = 12°C

8.51

7.09

Cdh Tj = +12 °C

0.960

0.966

Pdh Tj = Tbiv

5.69 kW

5.71 kW

COP Tj = Tbiv

2.68

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.27 kW

5.29 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.36

1.71

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

15 W

15 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

1.16 kW

1.16 kW

Annual energy consumption Qhe

2829 kWh

3989 kWh