Certificate holders

Subtype

RIELLO NXHP 004

Certificate Holder
Riello S.p.A.
Via Ing. Pilade Riello 7
37045 Legnago (VR)
Italy
Registration number
011-1W0616
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
RIELLO NXHP 004
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,390 kg

Certification Date
26.06.2023
Testing basis
HP KEYMARK Certification Scheme Rules Rev. 12
Generate PDF Export model CSV
  • Number of models 1

Models

RIELLO NXHP 004
Configure model
Model name
RIELLO NXHP 004
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.95 kW

3.75 kW

El input

0.81 kW

1.27 kW

COP

4.90

2.95

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.06 kW

Cooling capacity

3.35

EER

3.15

EN 14825

+7°C/+12°C

Pdesignc

3.35 kW

SEER

4.93

Pdc Tj = 35°C

3.35 kW

EER Tj = 35°C

3.15

Cdc Tj = 35 °C

 

Pdc Tj = 30°C

2.47 kW

EER Tj = 30°C

4.30

Cdc Tj = 30 °C

 

Pdc Tj = 25°C

1.59 kW

EER Tj = 25°C

6.09

Cdc Tj = 25 °C

 

Pdc Tj = 20°C

1.71 kW

EER Tj = 20°C

7.98

Cdc Tj = 20 °C

0.900

Poff

10 W

PTO

15 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

2010 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

47 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

131 %

Prated

3.80 kW

3.46 kW

SCOP

4.70

3.34

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.36 kW

3.06 kW

COP Tj = -7°C

2.86

1.97

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

2.05 kW

1.86 kW

COP Tj = +2°C

4.46

3.15

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

1.62 kW

1.52 kW

COP Tj = +7°C

6.83

4.88

Cdh Tj = +7 °C

0.937

0.952

Pdh Tj = 12°C

1.91 kW

1.84 kW

COP Tj = 12°C

9.23

6.91

Cdh Tj = +12 °C

0.928

0.944

Pdh Tj = Tbiv

3.36 kW

3.06 kW

COP Tj = Tbiv

2.86

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.08 kW

2.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.55

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

15 W

15 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.72 kW

0.76 kW

Annual energy consumption Qhe

1666 kWh

2138 kWh