BAXI AURIGA HP 40

Certificate Holder
BAXI S.p.A.
Via Trozzetti, 20
Bassano del Grappa (VI)
Italy
Registration number
007-DO0164
Certification Body
Kiwa Nederland B.V.
Subtype title
BAXI AURIGA HP 40
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

5,600 kg

Certification Date
27.06.2023
Testing basis
European KEYMARK Scheme for Heat Pumps (v11)
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

AURIGA HP 40T
Configure model
Model name
AURIGA HP 40T
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

40.20 kW

29.00 kW

El input

9.50 kW

9.67 kW

COP

4.30

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

9.75 kW

8.84 kW

Cooling capacity

30.60

37.70

EER

3.10

4.26

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

30.60 kW

37.70 kW

SEER

5.18

6.61

Pdc Tj = 35°C

30.60 kW

37.70 kW

EER Tj = 35°C

3.10

4.26

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

22.20 kW

27.70 kW

EER Tj = 30°C

4.37

5.51

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

14.20 kW

16.85 kW

EER Tj = 25°C

5.85

7.17

Cdc Tj = 25 °C

1.000

1.000

Pdc Tj = 20°C

8.82 kW

9.44 kW

EER Tj = 20°C

7.43

9.67

Cdc Tj = 20 °C

0.900

0.900

Poff

0 W

0 W

PTO

58 W

58 W

PSB

58 W

58 W

PCK

60 W

60 W

Annual energy consumption Qce

18360 kWh

22620 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

189 %

142 %

Prated

30.00 kW

23.70 kW

SCOP

4.80

3.61

Tbiv

-5 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

26.20 kW

20.50 kW

COP Tj = -7°C

2.75

2.15

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

16.59 kW

12.52 kW

COP Tj = +2°C

5.00

3.77

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

10.34 kW

8.39 kW

COP Tj = +7°C

6.28

4.50

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

10.40 kW

9.77 kW

COP Tj = 12°C

8.34

6.85

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

24.20 kW

18.73 kW

COP Tj = Tbiv

2.99

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

29.12 kW

22.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

60 °C

60 °C

Poff

0 W

0 W

PTO

58 W

58 W

PSB

58 W

58 W

PCK

60 W

60 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.88 kW

0.90 kW

Annual energy consumption Qhe

13545 kWh

13692 kWh

AURIGA HP/TX 40T
Configure model
Model name
AURIGA HP/TX 40T
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

40.20 kW

29.00 kW

El input

9.50 kW

9.67 kW

COP

4.30

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

9.75 kW

8.84 kW

Cooling capacity

30.60

37.70

EER

3.10

4.26

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

30.60 kW

37.70 kW

SEER

5.18

6.61

Pdc Tj = 35°C

30.60 kW

37.70 kW

EER Tj = 35°C

3.10

4.26

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

22.20 kW

27.70 kW

EER Tj = 30°C

4.37

5.51

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

14.20 kW

16.85 kW

EER Tj = 25°C

5.85

7.17

Cdc Tj = 25 °C

1.000

1.000

Pdc Tj = 20°C

8.82 kW

9.44 kW

EER Tj = 20°C

7.43

9.67

Cdc Tj = 20 °C

0.900

0.900

Poff

0 W

0 W

PTO

58 W

58 W

PSB

58 W

58 W

PCK

60 W

60 W

Annual energy consumption Qce

18360 kWh

22620 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

189 %

142 %

Prated

30.00 kW

23.70 kW

SCOP

4.80

3.61

Tbiv

-5 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

26.20 kW

20.50 kW

COP Tj = -7°C

2.75

2.15

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

16.59 kW

12.52 kW

COP Tj = +2°C

5.00

3.77

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

10.34 kW

8.39 kW

COP Tj = +7°C

6.28

4.50

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

10.40 kW

9.77 kW

COP Tj = 12°C

8.34

6.85

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

24.20 kW

18.73 kW

COP Tj = Tbiv

2.99

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

29.12 kW

22.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

60 °C

60 °C

Poff

0 W

0 W

PTO

58 W

58 W

PSB

58 W

58 W

PCK

60 W

60 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.88 kW

0.90 kW

Annual energy consumption Qhe

13545 kWh

13692 kWh