2,200 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.00 kW
11.30 kW
El input
2.65 kW
3.73 kW
COP
4.53
3.03
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
138 %
Prated
13.00 kW
12.00 kW
SCOP
4.69
3.51
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.50 kW
10.62 kW
COP Tj = -7°C
2.71
2.16
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
7.00 kW
6.46 kW
COP Tj = +2°C
4.48
3.45
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.60 kW
4.15 kW
COP Tj = +7°C
6.86
4.57
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
4.80 kW
4.40 kW
COP Tj = 12°C
8.95
6.12
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
11.50 kW
10.62 kW
COP Tj = Tbiv
2.71
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.37
1.96
WTOL
65 °C
65 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5725 kWh
7051 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
117 %
COP
2.70
Heating up time
1:50 h:min
Standby power input
67.0 W
Reference hot water temperature
52.0 °C
Mixed water at 40°C
290 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.00 kW
11.30 kW
El input
2.65 kW
3.73 kW
COP
4.53
3.03
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
138 %
Prated
13.00 kW
12.00 kW
SCOP
4.69
3.51
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.50 kW
10.62 kW
COP Tj = -7°C
2.71
2.16
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
7.00 kW
6.46 kW
COP Tj = +2°C
4.48
3.45
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.60 kW
4.15 kW
COP Tj = +7°C
6.86
4.57
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
4.80 kW
4.40 kW
COP Tj = 12°C
8.95
6.12
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
11.50 kW
10.62 kW
COP Tj = Tbiv
2.71
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.37
1.96
WTOL
65 °C
65 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5725 kWh
7051 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.00 kW
11.30 kW
El input
2.65 kW
3.73 kW
COP
4.53
3.03
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
138 %
Prated
13.00 kW
12.00 kW
SCOP
4.69
3.51
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.50 kW
10.62 kW
COP Tj = -7°C
2.71
2.16
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
7.00 kW
6.46 kW
COP Tj = +2°C
4.48
3.45
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.60 kW
4.15 kW
COP Tj = +7°C
6.86
4.57
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
4.80 kW
4.40 kW
COP Tj = 12°C
8.95
6.12
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
11.50 kW
10.62 kW
COP Tj = Tbiv
2.71
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.37
1.96
WTOL
65 °C
65 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5725 kWh
7051 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
117 %
COP
2.70
Heating up time
1:50 h:min
Standby power input
67.0 W
Reference hot water temperature
52.0 °C
Mixed water at 40°C
290 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.00 kW
15.00 kW
El input
3.62 kW
5.18 kW
COP
4.42
2.90
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
138 %
Prated
16.00 kW
16.00 kW
SCOP
4.48
3.53
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
14.15 kW
14.15 kW
COP Tj = -7°C
2.65
2.06
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
8.62 kW
8.62 kW
COP Tj = +2°C
4.11
3.31
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.54 kW
5.54 kW
COP Tj = +7°C
6.86
5.23
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
5.20 kW
4.49 kW
COP Tj = 12°C
8.81
6.35
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
14.15 kW
14.15 kW
COP Tj = Tbiv
2.65
2.06
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.80 kW
14.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.37
1.82
WTOL
65 °C
65 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.20 kW
2.00 kW
Annual energy consumption Qhe
7385 kWh
9379 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
117 %
COP
2.70
Heating up time
1:50 h:min
Standby power input
67.0 W
Reference hot water temperature
52.0 °C
Mixed water at 40°C
290 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.00 kW
15.00 kW
El input
3.62 kW
5.18 kW
COP
4.42
2.90
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
138 %
Prated
16.00 kW
16.00 kW
SCOP
4.48
3.53
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
14.15 kW
14.15 kW
COP Tj = -7°C
2.65
2.06
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
8.62 kW
8.62 kW
COP Tj = +2°C
4.11
3.31
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.54 kW
5.54 kW
COP Tj = +7°C
6.86
5.23
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
5.20 kW
4.49 kW
COP Tj = 12°C
8.81
6.35
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
14.20 kW
14.15 kW
COP Tj = Tbiv
2.65
2.06
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.80 kW
14.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.37
1.82
WTOL
65 °C
65 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.20 kW
2.00 kW
Annual energy consumption Qhe
7385 kWh
9379 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.00 kW
15.00 kW
El input
3.62 kW
5.18 kW
COP
4.42
2.90
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
138 %
Prated
16.00 kW
16.00 kW
SCOP
4.48
3.53
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
14.15 kW
14.15 kW
COP Tj = -7°C
2.65
2.06
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
8.62 kW
8.62 kW
COP Tj = +2°C
4.11
3.31
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.54 kW
5.54 kW
COP Tj = +7°C
6.86
5.23
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
5.20 kW
4.49 kW
COP Tj = 12°C
8.81
6.35
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
14.20 kW
14.15 kW
COP Tj = Tbiv
2.65
2.06
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.80 kW
14.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.37
1.82
WTOL
65 °C
65 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.20 kW
2.00 kW
Annual energy consumption Qhe
7385 kWh
9379 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
117 %
COP
2.70
Heating up time
1:50 h:min
Standby power input
67.0 W
Reference hot water temperature
52.0 °C
Mixed water at 40°C
290 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.00 kW
11.30 kW
El input
2.65 kW
3.73 kW
COP
4.53
3.03
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
185 %
138 %
Prated
13.00 kW
12.00 kW
SCOP
4.69
3.51
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.50 kW
10.60 kW
COP Tj = -7°C
2.71
2.16
Cdh Tj = -7 °C
Pdh Tj = +2°C
7.00 kW
6.50 kW
COP Tj = +2°C
4.48
3.45
Cdh Tj = +2 °C
Pdh Tj = +7°C
5.60 kW
4.20 kW
COP Tj = +7°C
6.86
4.57
Cdh Tj = +7 °C
Pdh Tj = 12°C
4.80 kW
4.40 kW
COP Tj = 12°C
8.95
6.12
Cdh Tj = +12 °C
Pdh Tj = Tbiv
11.50 kW
10.60 kW
COP Tj = Tbiv
2.71
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.37
1.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5 kWh
7 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
117 %
COP
2.70
Heating up time
1:50 h:min
Standby power input
67.0 W
Reference hot water temperature
52.0 °C
Mixed water at 40°C
290 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.00 kW
11.30 kW
El input
2.65 kW
3.73 kW
COP
4.53
3.03
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
138 %
Prated
13.00 kW
12.00 kW
SCOP
4.69
3.51
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.50 kW
10.60 kW
COP Tj = -7°C
2.71
2.16
Cdh Tj = -7 °C
Pdh Tj = +2°C
7.00 kW
6.50 kW
COP Tj = +2°C
4.48
3.45
Cdh Tj = +2 °C
Pdh Tj = +7°C
5.60 kW
4.20 kW
COP Tj = +7°C
6.86
4.57
Cdh Tj = +7 °C
Pdh Tj = 12°C
4.80 kW
4.40 kW
COP Tj = 12°C
8.95
6.12
Cdh Tj = +12 °C
Pdh Tj = Tbiv
11.50 kW
10.60 kW
COP Tj = Tbiv
2.71
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.37
1.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5 kWh
7 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
117 %
COP
2.70
Heating up time
1:50 h:min
Standby power input
67.0 W
Reference hot water temperature
52.0 °C
Mixed water at 40°C
290 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.00 kW
15.00 kW
El input
3.62 kW
5.18 kW
COP
4.42
2.90
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
138 %
Prated
16.00 kW
16.00 kW
SCOP
4.48
3.53
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
14.15 kW
14.20 kW
COP Tj = -7°C
2.65
2.06
Cdh Tj = -7 °C
Pdh Tj = +2°C
8.62 kW
8.62 kW
COP Tj = +2°C
4.11
3.31
Cdh Tj = +2 °C
Pdh Tj = +7°C
5.54 kW
5.50 kW
COP Tj = +7°C
6.86
5.23
Cdh Tj = +7 °C
Pdh Tj = 12°C
5.20 kW
4.50 kW
COP Tj = 12°C
8.81
6.35
Cdh Tj = +12 °C
Pdh Tj = Tbiv
14.15 kW
14.20 kW
COP Tj = Tbiv
2.65
2.06
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.80 kW
14.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.37
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.20 kW
2.00 kW
Annual energy consumption Qhe
7 kWh
9 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
117 %
COP
2.70
Heating up time
1:50 h:min
Standby power input
67.0 W
Reference hot water temperature
52.0 °C
Mixed water at 40°C
290 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.00 kW
15.00 kW
El input
3.62 kW
5.18 kW
COP
4.42
2.90
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
138 %
Prated
16.00 kW
16.00 kW
SCOP
4.48
3.53
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
14.15 kW
14.20 kW
COP Tj = -7°C
2.65
2.06
Cdh Tj = -7 °C
Pdh Tj = +2°C
8.62 kW
8.62 kW
COP Tj = +2°C
4.11
3.31
Cdh Tj = +2 °C
Pdh Tj = +7°C
5.54 kW
5.50 kW
COP Tj = +7°C
6.86
5.23
Cdh Tj = +7 °C
Pdh Tj = 12°C
5.20 kW
4.50 kW
COP Tj = 12°C
8.81
6.35
Cdh Tj = +12 °C
Pdh Tj = Tbiv
14.15 kW
14.20 kW
COP Tj = Tbiv
2.65
2.06
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.80 kW
14.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.37
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.20 kW
2.00 kW
Annual energy consumption Qhe
7 kWh
9 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
117 %
COP
2.70
Heating up time
1:5 h:min
Standby power input
67.0 W
Reference hot water temperature
52.0 °C
Mixed water at 40°C
290 l