1,000 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.00 kW
4.31 kW
El input
1.03 kW
1.52 kW
COP
4.85
2.83
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
125 %
Prated
6.00 kW
5.00 kW
SCOP
4.46
3.20
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.87 kW
4.42 kW
COP Tj = -7°C
2.99
2.16
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
2.96 kW
2.69 kW
COP Tj = +2°C
4.18
3.17
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
1.90 kW
1.73 kW
COP Tj = +7°C
6.11
4.03
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
1.88 kW
1.70 kW
COP Tj = 12°C
7.70
4.73
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
4.87 kW
4.42 kW
COP Tj = Tbiv
2.99
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.60 kW
4.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
2.00
WTOL
65 °C
65 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.40 kW
0.80 kW
Annual energy consumption Qhe
2548 kWh
3224 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.00 kW
4.30 kW
El input
1.03 kW
1.52 kW
COP
4.85
2.83
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
125 %
Prated
6.00 kW
5.00 kW
SCOP
4.46
3.20
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.87 kW
4.42 kW
COP Tj = -7°C
2.99
2.16
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
2.96 kW
2.69 kW
COP Tj = +2°C
4.18
3.17
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
1.90 kW
1.73 kW
COP Tj = +7°C
6.11
4.03
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
1.88 kW
1.70 kW
COP Tj = 12°C
7.70
4.73
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
4.87 kW
4.42 kW
COP Tj = Tbiv
2.99
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.59 kW
4.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
2.00
WTOL
65 °C
65 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.41 kW
0.80 kW
Annual energy consumption Qhe
2548 kWh
3224 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.86
Heating up time
2:20 h:min
Standby power input
58.0 W
Reference hot water temperature
52.1 °C
Mixed water at 40°C
206 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.00 kW
4.30 kW
El input
1.03 kW
1.52 kW
COP
4.85
2.83
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
125 %
Prated
6.00 kW
5.00 kW
SCOP
4.46
3.20
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.87 kW
4.40 kW
COP Tj = -7°C
2.99
2.16
Cdh Tj = -7 °C
Pdh Tj = +2°C
2.96 kW
2.69 kW
COP Tj = +2°C
4.18
3.17
Cdh Tj = +2 °C
Pdh Tj = +7°C
1.90 kW
1.73 kW
COP Tj = +7°C
6.10
4.03
Cdh Tj = +7 °C
Pdh Tj = 12°C
1.80 kW
1.70 kW
COP Tj = 12°C
7.70
4.73
Cdh Tj = +12 °C
Pdh Tj = Tbiv
4.87 kW
4.40 kW
COP Tj = Tbiv
2.99
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.59 kW
4.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
2.00
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.41 kW
0.80 kW
Annual energy consumption Qhe
2 kWh
3 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.86
Heating up time
2:20 h:min
Standby power input
58.0 W
Reference hot water temperature
52.1 °C
Mixed water at 40°C
206 l