Certificate holders

Subtype

TTL 9.6/12.6 AC

Certificate Holder
tecalor GmbH
Fürstenbergerstr. 77
37603 Holzminden
Germany
Registration number
011-1W0648
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
TTL 9.6/12.6 AC
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R452B
Mass of Refrigerant

5,000 kg

Certification Date
22.06.2023
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 12 (as of 2023-04)
Generate PDF Export model CSV
  • Number of models 2

Models

TTL 9.6 AC
Configure model
Model name
TTL 9.6 AC
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.24 kW

9.03 kW

El input

1.79 kW

2.88 kW

COP

4.61

3.14

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

135 %

Prated

11.20 kW

11.60 kW

SCOP

4.31

3.44

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.89 kW

10.22 kW

COP Tj = -7°C

3.36

2.59

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.12 kW

7.06 kW

COP Tj = +2°C

4.17

3.28

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

8.31 kW

8.01 kW

COP Tj = +7°C

5.24

4.25

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

9.57 kW

9.28 kW

COP Tj = 12°C

6.41

5.25

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

9.89 kW

10.22 kW

COP Tj = Tbiv

3.36

2.59

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.25 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.11

2.32

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

38 W

38 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.95 kW

1.60 kW

Annual energy consumption Qhe

5368 kWh

6969 kWh

TTL 12.6 AC
Configure model
Model name
TTL 12.6 AC
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.24 kW

9.03 kW

El input

1.79 kW

2.88 kW

COP

4.61

3.14

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

171 %

139 %

Prated

14.00 kW

14.80 kW

SCOP

4.35

3.54

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.34 kW

13.11 kW

COP Tj = -7°C

3.00

2.41

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.70 kW

8.08 kW

COP Tj = +2°C

4.31

3.48

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

8.28 kW

8.00 kW

COP Tj = +7°C

5.31

4.37

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

9.52 kW

9.23 kW

COP Tj = 12°C

6.43

5.28

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

12.34 kW

13.11 kW

COP Tj = Tbiv

3.00

2.41

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.63 kW

13.48 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.93

2.27

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

38 W

38 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.37 kW

1.32 kW

Annual energy consumption Qhe

6657 kWh

8643 kWh