2,200 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.20 kW
12.00 kW
El input
2.46 kW
3.75 kW
COP
4.95
3.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
56 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
137 %
Prated
11.90 kW
13.00 kW
SCOP
4.63
3.55
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.56 kW
11.49 kW
COP Tj = -7°C
2.89
2.20
Cdh Tj = -7 °C
0.997
0.998
Pdh Tj = +2°C
6.20 kW
7.23 kW
COP Tj = +2°C
4.48
3.28
Cdh Tj = +2 °C
0.993
0.995
Pdh Tj = +7°C
5.13 kW
4.84 kW
COP Tj = +7°C
6.67
4.67
Cdh Tj = +7 °C
0.987
0.990
Pdh Tj = 12°C
6.09 kW
6.05 kW
COP Tj = 12°C
10.08
7.38
Cdh Tj = +12 °C
0.983
0.988
Pdh Tj = Tbiv
10.56 kW
11.49 kW
COP Tj = Tbiv
2.89
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.19 kW
11.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.76
1.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
10 W
10 W
PTO
20 W
20 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.71 kW
1.80 kW
Annual energy consumption Qhe
5346 kWh
7656 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.20 kW
14.00 kW
El input
3.02 kW
4.52 kW
COP
4.70
3.10
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
56 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
134 %
Prated
12.30 kW
13.40 kW
SCOP
4.83
3.48
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.91 kW
11.89 kW
COP Tj = -7°C
2.81
2.13
Cdh Tj = -7 °C
0.997
0.998
Pdh Tj = +2°C
6.72 kW
7.23 kW
COP Tj = +2°C
4.50
3.18
Cdh Tj = +2 °C
0.993
0.996
Pdh Tj = +7°C
5.08 kW
4.83 kW
COP Tj = +7°C
6.70
4.70
Cdh Tj = +7 °C
0.987
0.990
Pdh Tj = 12°C
6.05 kW
6.03 kW
COP Tj = 12°C
10.15
7.41
Cdh Tj = +12 °C
0.983
0.988
Pdh Tj = Tbiv
10.91 kW
11.89 kW
COP Tj = Tbiv
2.81
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.22 kW
11.49 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.60
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
10 W
10 W
PTO
20 W
20 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.08 kW
1.91 kW
Annual energy consumption Qhe
5344 kWh
8108 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.00 kW
16.00 kW
El input
3.52 kW
5.33 kW
COP
4.55
3.00
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
56 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
131 %
Prated
12.50 kW
13.80 kW
SCOP
4.83
3.40
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.10 kW
12.19 kW
COP Tj = -7°C
2.84
2.07
Cdh Tj = -7 °C
0.997
0.998
Pdh Tj = +2°C
7.11 kW
7.46 kW
COP Tj = +2°C
4.53
3.16
Cdh Tj = +2 °C
0.994
0.996
Pdh Tj = +7°C
4.96 kW
4.66 kW
COP Tj = +7°C
6.59
4.61
Cdh Tj = +7 °C
0.987
0.990
Pdh Tj = 12°C
6.09 kW
6.08 kW
COP Tj = 12°C
9.98
7.50
Cdh Tj = +12 °C
0.984
0.988
Pdh Tj = Tbiv
11.10 kW
12.19 kW
COP Tj = Tbiv
2.84
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.68 kW
11.38 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.78
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
10 W
10 W
PTO
20 W
20 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.82 kW
2.42 kW
Annual energy consumption Qhe
5430 kWh
8479 kWh