1,350 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.50 kW
8.50 kW
El input
1.79 kW
2.74 kW
COP
4.75
3.10
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
54 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
131 %
Prated
8.00 kW
8.00 kW
SCOP
4.58
3.35
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.03 kW
7.24 kW
COP Tj = -7°C
2.77
2.32
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.46 kW
4.32 kW
COP Tj = +2°C
4.26
3.21
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
2.82 kW
2.87 kW
COP Tj = +7°C
6.27
4.13
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
3.33 kW
3.21 kW
COP Tj = 12°C
11.06
5.60
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
7.03 kW
7.24 kW
COP Tj = Tbiv
2.77
2.32
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.69 kW
6.71 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.00
1.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
10 W
10 W
PTO
20 W
20 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.31 kW
1.29 kW
Annual energy consumption Qhe
3609 kWh
4947 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.00 kW
9.50 kW
El input
2.13 kW
3.11 kW
COP
4.70
3.05
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
54 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
131 %
Prated
9.00 kW
9.00 kW
SCOP
4.63
3.35
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.75 kW
7.90 kW
COP Tj = -7°C
2.90
2.33
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
5.13 kW
4.89 kW
COP Tj = +2°C
4.42
3.22
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.02 kW
3.14 kW
COP Tj = +7°C
6.25
4.23
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
3.21 kW
3.15 kW
COP Tj = 12°C
10.41
5.33
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
7.75 kW
7.90 kW
COP Tj = Tbiv
2.90
2.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.54 kW
7.51 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.84
2.01
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
10 W
10 W
PTO
20 W
20 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.46 kW
1.49 kW
Annual energy consumption Qhe
4013 kWh
5544 kWh