Certificate holders

Subtype

i-290 0115-0118

Certificate Holder
Advantix S.p.A.
Via San Giuseppe Lavoratore, 24
37040 Arcole Verona
Italy
Registration number
ICIM-PDC-000210
Certification Body
ICIM S.p.A.
Subtype title
i-290 0115-0118
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,270 kg

Certification Date
31.08.2023
Testing basis
V12
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

i-290 0115
Configure model
Model name
i-290 0115
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.33 kW

15.23 kW

El input

3.30 kW

4.52 kW

COP

4.94

3.37

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.70 kW

Cooling capacity

12.41

EER

3.35

EN 14825

+7°C/+12°C

Pdesignc

12.41 kW

SEER

5.02

Pdc Tj = 35°C

12.41 kW

EER Tj = 35°C

3.35

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

9.77 kW

EER Tj = 30°C

4.55

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

5.84 kW

EER Tj = 25°C

5.87

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

3.36 kW

EER Tj = 20°C

5.60

Cdc Tj = 20 °C

0.963

Poff

22 W

PTO

0 W

PSB

28 W

PCK

0 W

Annual energy consumption Qce

1483 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

149 %

Prated

14.60 kW

13.50 kW

SCOP

4.85

3.79

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.90 kW

11.90 kW

COP Tj = -7°C

2.93

2.30

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

8.30 kW

7.40 kW

COP Tj = +2°C

4.79

3.67

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

6.10 kW

6.00 kW

COP Tj = +7°C

6.45

4.91

Cdh Tj = +7 °C

0.977

0.982

Pdh Tj = 12°C

5.50 kW

7.10 kW

COP Tj = 12°C

8.11

7.67

Cdh Tj = +12 °C

0.969

0.976

Pdh Tj = Tbiv

12.90 kW

11.90 kW

COP Tj = Tbiv

2.93

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.00 kW

11.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.65

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

68 °C

68 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.60 kW

2.50 kW

Annual energy consumption Qhe

6233 kWh

7347 kWh

i-290 0118
Configure model
Model name
i-290 0118
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

18.72 kW

17.38 kW

El input

4.05 kW

5.32 kW

COP

4.62

3.27

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

4.35 kW

Cooling capacity

13.75

EER

3.16

EN 14825

+7°C/+12°C

Pdesignc

13.75 kW

SEER

5.04

Pdc Tj = 35°C

13.75 kW

EER Tj = 35°C

3.16

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

10.39 kW

EER Tj = 30°C

4.65

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

6.90 kW

EER Tj = 25°C

5.91

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

3.36 kW

EER Tj = 20°C

5.56

Cdc Tj = 20 °C

0.964

Poff

22 W

PTO

0 W

PSB

28 W

PCK

0 W

Annual energy consumption Qce

1635 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

146 %

Prated

15.00 kW

14.00 kW

SCOP

4.76

3.73

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.30 kW

12.40 kW

COP Tj = -7°C

2.86

2.26

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

8.30 kW

7.60 kW

COP Tj = +2°C

4.76

3.63

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

6.00 kW

6.00 kW

COP Tj = +7°C

6.28

4.93

Cdh Tj = +7 °C

0.977

0.982

Pdh Tj = 12°C

5.50 kW

6.80 kW

COP Tj = 12°C

7.84

6.72

Cdh Tj = +12 °C

0.969

0.978

Pdh Tj = Tbiv

13.30 kW

12.40 kW

COP Tj = Tbiv

2.86

2.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.40 kW

11.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.57

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

68 °C

68 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.60 kW

2.40 kW

Annual energy consumption Qhe

6496 kWh

7751 kWh