1,150 kg
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
2.85 kW
2.46 kW
El input
0.56 kW
0.81 kW
COP
5.05
3.03
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
219 %
162 %
Prated
7.50 kW
7.50 kW
SCOP
5.67
4.26
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.63 kW
6.63 kW
COP Tj = -7°C
4.65
3.25
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
4.04 kW
4.04 kW
COP Tj = +2°C
5.72
4.26
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
2.60 kW
2.60 kW
COP Tj = +7°C
6.50
5.02
Cdh Tj = +7 °C
1.000
0.990
Pdh Tj = 12°C
1.84 kW
1.79 kW
COP Tj = 12°C
6.67
5.40
Cdh Tj = +12 °C
1.000
0.990
Pdh Tj = Tbiv
7.50 kW
7.50 kW
COP Tj = Tbiv
4.37
3.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.50 kW
7.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.37
3.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
3 W
3 W
PTO
1 W
3 W
PSB
8 W
8 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2732 kWh
3637 kWh
Water/Water Heat Pump
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.84 kW
3.38 kW
El input
0.54 kW
0.86 kW
COP
7.05
3.92
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
307 %
217 %
Prated
10.00 kW
10.00 kW
SCOP
7.87
5.63
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.89 kW
8.93 kW
COP Tj = -7°C
5.70
3.85
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
5.41 kW
5.48 kW
COP Tj = +2°C
7.98
5.55
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.53 kW
3.53 kW
COP Tj = +7°C
9.78
7.24
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
2.06 kW
1.95 kW
COP Tj = 12°C
9.64
7.94
Cdh Tj = +12 °C
0.950
0.940
Pdh Tj = Tbiv
10.06 kW
9.96 kW
COP Tj = Tbiv
5.21
3.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.06 kW
9.96 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.21
3.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
3 W
3 W
PTO
10 W
15 W
PSB
8 W
8 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2624 kWh
3669 kWh
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
2.85 kW
2.46 kW
El input
0.56 kW
0.81 kW
COP
5.05
3.03
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
219 %
162 %
Prated
7.50 kW
7.50 kW
SCOP
5.67
4.26
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.63 kW
6.63 kW
COP Tj = -7°C
4.65
3.25
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
4.04 kW
4.04 kW
COP Tj = +2°C
5.72
4.26
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
2.60 kW
2.60 kW
COP Tj = +7°C
6.50
5.02
Cdh Tj = +7 °C
1.000
0.990
Pdh Tj = 12°C
1.84 kW
1.79 kW
COP Tj = 12°C
6.67
5.40
Cdh Tj = +12 °C
1.000
0.990
Pdh Tj = Tbiv
7.50 kW
7.50 kW
COP Tj = Tbiv
4.37
3.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.50 kW
7.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.37
3.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
3 W
3 W
PTO
1 W
3 W
PSB
8 W
8 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2732 kWh
3637 kWh
Water/Water Heat Pump
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.84 kW
3.38 kW
El input
0.54 kW
0.86 kW
COP
7.05
3.92
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
307 %
217 %
Prated
10.00 kW
10.00 kW
SCOP
7.87
5.63
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.89 kW
8.93 kW
COP Tj = -7°C
5.70
3.85
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
5.41 kW
5.48 kW
COP Tj = +2°C
7.98
5.55
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.53 kW
3.53 kW
COP Tj = +7°C
9.78
7.24
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
2.06 kW
1.95 kW
COP Tj = 12°C
9.64
7.94
Cdh Tj = +12 °C
0.950
0.940
Pdh Tj = Tbiv
10.06 kW
9.96 kW
COP Tj = Tbiv
5.21
3.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.06 kW
9.96 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.21
3.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
3 W
3 W
PTO
10 W
15 W
PSB
8 W
8 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2624 kWh
3669 kWh
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
2.85 kW
2.46 kW
El input
0.56 kW
0.81 kW
COP
5.05
3.03
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
219 %
162 %
Prated
7.50 kW
7.50 kW
SCOP
5.67
4.26
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.63 kW
6.63 kW
COP Tj = -7°C
4.65
3.25
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
4.04 kW
4.04 kW
COP Tj = +2°C
5.72
4.26
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
2.60 kW
2.60 kW
COP Tj = +7°C
6.50
5.02
Cdh Tj = +7 °C
1.000
0.990
Pdh Tj = 12°C
1.84 kW
1.79 kW
COP Tj = 12°C
6.67
5.40
Cdh Tj = +12 °C
1.000
0.990
Pdh Tj = Tbiv
7.50 kW
7.50 kW
COP Tj = Tbiv
4.37
3.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.50 kW
7.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.37
3.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
3 W
3 W
PTO
1 W
3 W
PSB
8 W
8 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2732 kWh
3637 kWh
Water/Water Heat Pump
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.84 kW
3.38 kW
El input
0.54 kW
0.86 kW
COP
7.05
3.92
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
307 %
217 %
Prated
10.00 kW
10.00 kW
SCOP
7.87
5.63
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.89 kW
8.93 kW
COP Tj = -7°C
5.70
3.85
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
5.41 kW
5.48 kW
COP Tj = +2°C
7.98
5.55
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.53 kW
3.53 kW
COP Tj = +7°C
9.78
7.24
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
2.06 kW
1.95 kW
COP Tj = 12°C
9.64
7.94
Cdh Tj = +12 °C
0.950
0.940
Pdh Tj = Tbiv
10.06 kW
9.96 kW
COP Tj = Tbiv
5.21
3.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.06 kW
9.96 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.21
3.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
3 W
3 W
PTO
10 W
15 W
PSB
8 W
8 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2624 kWh
3669 kWh
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
2.85 kW
2.46 kW
El input
0.56 kW
0.81 kW
COP
5.05
3.03
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
219 %
162 %
Prated
7.50 kW
7.50 kW
SCOP
5.67
4.26
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.63 kW
6.63 kW
COP Tj = -7°C
4.65
3.25
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
4.04 kW
4.04 kW
COP Tj = +2°C
5.72
4.26
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
2.60 kW
2.60 kW
COP Tj = +7°C
6.50
5.02
Cdh Tj = +7 °C
1.000
0.990
Pdh Tj = 12°C
1.84 kW
1.79 kW
COP Tj = 12°C
6.67
5.40
Cdh Tj = +12 °C
1.000
0.990
Pdh Tj = Tbiv
7.50 kW
7.50 kW
COP Tj = Tbiv
4.37
3.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.50 kW
7.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.37
3.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
3 W
3 W
PTO
1 W
3 W
PSB
8 W
8 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2732 kWh
3637 kWh
Water/Water Heat Pump
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.84 kW
3.38 kW
El input
0.54 kW
0.86 kW
COP
7.05
3.92
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
307 %
217 %
Prated
10.00 kW
10.00 kW
SCOP
7.87
5.63
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.89 kW
8.93 kW
COP Tj = -7°C
5.70
3.85
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
5.41 kW
5.48 kW
COP Tj = +2°C
7.98
5.55
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.53 kW
3.53 kW
COP Tj = +7°C
9.78
7.24
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
2.06 kW
1.95 kW
COP Tj = 12°C
9.64
7.94
Cdh Tj = +12 °C
0.950
0.940
Pdh Tj = Tbiv
10.06 kW
9.96 kW
COP Tj = Tbiv
5.21
3.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.06 kW
9.96 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.21
3.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
3 W
3 W
PTO
10 W
15 W
PSB
8 W
8 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2624 kWh
3669 kWh
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
2.85 kW
2.46 kW
El input
0.56 kW
0.81 kW
COP
5.05
3.03
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
219 %
162 %
Prated
7.50 kW
7.50 kW
SCOP
5.67
4.26
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.63 kW
6.63 kW
COP Tj = -7°C
4.65
3.25
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
4.04 kW
4.04 kW
COP Tj = +2°C
5.72
4.26
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
2.60 kW
2.60 kW
COP Tj = +7°C
6.50
5.02
Cdh Tj = +7 °C
1.000
0.990
Pdh Tj = 12°C
1.84 kW
1.79 kW
COP Tj = 12°C
6.67
5.40
Cdh Tj = +12 °C
1.000
0.990
Pdh Tj = Tbiv
7.50 kW
7.50 kW
COP Tj = Tbiv
4.37
3.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.50 kW
7.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.37
3.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
3 W
3 W
PTO
1 W
3 W
PSB
8 W
8 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2732 kWh
3637 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
126 %
COP
3.01
Heating up time
2:10 h:min
Standby power input
48.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
235 l
Water/Water Heat Pump
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.84 kW
3.38 kW
El input
0.54 kW
0.86 kW
COP
7.05
3.92
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
307 %
217 %
Prated
10.00 kW
10.00 kW
SCOP
7.87
5.63
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.89 kW
8.93 kW
COP Tj = -7°C
5.70
3.85
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
5.41 kW
5.48 kW
COP Tj = +2°C
7.98
5.55
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.53 kW
3.53 kW
COP Tj = +7°C
9.78
7.24
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
2.06 kW
1.95 kW
COP Tj = 12°C
9.64
7.94
Cdh Tj = +12 °C
0.950
0.940
Pdh Tj = Tbiv
10.06 kW
9.96 kW
COP Tj = Tbiv
5.21
3.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.06 kW
9.96 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.21
3.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
3 W
3 W
PTO
10 W
15 W
PSB
8 W
8 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2624 kWh
3669 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
145 %
COP
3.48
Heating up time
2:10 h:min
Standby power input
43.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
235 l
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
2.85 kW
2.46 kW
El input
0.56 kW
0.81 kW
COP
5.05
3.03
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
219 %
162 %
Prated
7.50 kW
7.50 kW
SCOP
5.67
4.26
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.63 kW
6.63 kW
COP Tj = -7°C
4.65
3.25
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
4.04 kW
4.04 kW
COP Tj = +2°C
5.72
4.26
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
2.60 kW
2.60 kW
COP Tj = +7°C
6.50
5.02
Cdh Tj = +7 °C
1.000
0.990
Pdh Tj = 12°C
1.84 kW
1.79 kW
COP Tj = 12°C
6.67
5.40
Cdh Tj = +12 °C
1.000
0.990
Pdh Tj = Tbiv
7.50 kW
7.50 kW
COP Tj = Tbiv
4.37
3.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.50 kW
7.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.37
3.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
3 W
3 W
PTO
1 W
3 W
PSB
8 W
8 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2732 kWh
3637 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
126 %
COP
3.01
Heating up time
2:10 h:min
Standby power input
48.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
235 l
Water/Water Heat Pump
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.84 kW
3.38 kW
El input
0.54 kW
0.86 kW
COP
7.05
3.92
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
307 %
217 %
Prated
10.00 kW
10.00 kW
SCOP
7.87
5.63
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.89 kW
8.93 kW
COP Tj = -7°C
5.70
3.85
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
5.41 kW
5.48 kW
COP Tj = +2°C
7.98
5.55
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.53 kW
3.53 kW
COP Tj = +7°C
9.78
7.24
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
2.06 kW
1.95 kW
COP Tj = 12°C
9.64
7.94
Cdh Tj = +12 °C
0.950
0.940
Pdh Tj = Tbiv
10.06 kW
9.96 kW
COP Tj = Tbiv
5.21
3.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.06 kW
9.96 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.21
3.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
3 W
3 W
PTO
10 W
15 W
PSB
8 W
8 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2624 kWh
3669 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
145 %
COP
3.48
Heating up time
2:10 h:min
Standby power input
43.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
235 l
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
2.85 kW
2.46 kW
El input
0.56 kW
0.81 kW
COP
5.05
3.03
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
219 %
162 %
Prated
7.50 kW
7.50 kW
SCOP
5.67
4.26
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.63 kW
6.63 kW
COP Tj = -7°C
4.65
3.25
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
4.04 kW
4.04 kW
COP Tj = +2°C
5.72
4.26
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
2.60 kW
2.60 kW
COP Tj = +7°C
6.50
5.02
Cdh Tj = +7 °C
1.000
0.990
Pdh Tj = 12°C
1.84 kW
1.79 kW
COP Tj = 12°C
6.67
5.40
Cdh Tj = +12 °C
1.000
0.990
Pdh Tj = Tbiv
7.50 kW
7.50 kW
COP Tj = Tbiv
4.37
3.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.50 kW
7.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.37
3.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
3 W
3 W
PTO
1 W
3 W
PSB
8 W
8 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2732 kWh
3637 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
126 %
COP
3.01
Heating up time
2:10 h:min
Standby power input
48.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
235 l
Water/Water Heat Pump
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.84 kW
3.38 kW
El input
0.54 kW
0.86 kW
COP
7.05
3.92
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
307 %
217 %
Prated
10.00 kW
10.00 kW
SCOP
7.87
5.63
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.89 kW
8.93 kW
COP Tj = -7°C
5.70
3.85
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
5.41 kW
5.48 kW
COP Tj = +2°C
7.98
5.55
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.53 kW
3.53 kW
COP Tj = +7°C
9.78
7.24
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
2.06 kW
1.95 kW
COP Tj = 12°C
9.64
7.94
Cdh Tj = +12 °C
0.950
0.940
Pdh Tj = Tbiv
10.06 kW
9.96 kW
COP Tj = Tbiv
5.21
3.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.06 kW
9.96 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.21
3.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
3 W
3 W
PTO
10 W
15 W
PSB
8 W
8 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2624 kWh
3669 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
145 %
COP
3.48
Heating up time
2:10 h:min
Standby power input
43.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
235 l
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
2.85 kW
2.46 kW
El input
0.56 kW
0.81 kW
COP
5.05
3.03
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
219 %
162 %
Prated
7.50 kW
7.50 kW
SCOP
5.67
4.26
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.63 kW
6.63 kW
COP Tj = -7°C
4.65
3.25
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
4.04 kW
4.04 kW
COP Tj = +2°C
5.72
4.26
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
2.60 kW
2.60 kW
COP Tj = +7°C
6.50
5.02
Cdh Tj = +7 °C
1.000
0.990
Pdh Tj = 12°C
1.84 kW
1.79 kW
COP Tj = 12°C
6.67
5.40
Cdh Tj = +12 °C
1.000
0.990
Pdh Tj = Tbiv
7.50 kW
7.50 kW
COP Tj = Tbiv
4.37
3.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.50 kW
7.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.37
3.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
3 W
3 W
PTO
1 W
3 W
PSB
8 W
8 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2732 kWh
3637 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
126 %
COP
3.01
Heating up time
2:10 h:min
Standby power input
48.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
235 l
Water/Water Heat Pump
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.84 kW
3.38 kW
El input
0.54 kW
0.86 kW
COP
7.05
3.92
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
307 %
217 %
Prated
10.00 kW
10.00 kW
SCOP
7.87
5.63
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.89 kW
8.93 kW
COP Tj = -7°C
5.70
3.85
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
5.41 kW
5.48 kW
COP Tj = +2°C
7.98
5.55
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.53 kW
3.53 kW
COP Tj = +7°C
9.78
7.24
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
2.06 kW
1.95 kW
COP Tj = 12°C
9.64
7.94
Cdh Tj = +12 °C
0.950
0.940
Pdh Tj = Tbiv
10.06 kW
9.96 kW
COP Tj = Tbiv
5.21
3.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.06 kW
9.96 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.21
3.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
3 W
3 W
PTO
10 W
15 W
PSB
8 W
8 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2624 kWh
3669 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
145 %
COP
3.48
Heating up time
2:10 h:min
Standby power input
43.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
235 l