1,050 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.20 kW
4.40 kW
El input
0.83 kW
1.49 kW
COP
5.05
2.95
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
196 %
137 %
Prated
5.54 kW
4.64 kW
SCOP
4.97
3.51
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.88 kW
4.10 kW
COP Tj = -7°C
3.03
2.12
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
2.94 kW
2.58 kW
COP Tj = +2°C
4.75
3.46
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
2.10 kW
1.73 kW
COP Tj = +7°C
6.98
4.35
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
1.80 kW
1.69 kW
COP Tj = 12°C
10.24
7.21
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
4.88 kW
4.04 kW
COP Tj = Tbiv
3.03
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.80 kW
4.04 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.79
1.71
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
5 W
5 W
PSB
15 W
15 W
PCK
28 W
28 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.74 kW
0.60 kW
Annual energy consumption Qhe
2291 kWh
2725 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.20 kW
5.70 kW
El input
1.22 kW
1.93 kW
COP
4.90
2.95
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
197 %
141 %
Prated
5.90 kW
5.60 kW
SCOP
4.99
3.61
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.19 kW
4.92 kW
COP Tj = -7°C
3.03
2.11
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
3.26 kW
3.03 kW
COP Tj = +2°C
4.77
3.50
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
2.00 kW
1.96 kW
COP Tj = +7°C
6.79
4.75
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
1.86 kW
1.84 kW
COP Tj = 12°C
10.66
7.90
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
5.19 kW
4.92 kW
COP Tj = Tbiv
3.03
2.11
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.78 kW
4.11 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.79
1.74
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
5 W
5 W
PSB
15 W
15 W
PCK
28 W
28 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.12 kW
1.49 kW
Annual energy consumption Qhe
2429 kWh
3188 kWh