Certificate holders

Subtype

Hi-Therma Split 10 12

Certificate Holder
Qingdao Hisense Hitachi Air-conditioning Systems Co.,Ltd.
Qianwangang Road
266555 Qingdao, Shandong
China
Registration number
011-1W0633
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Hi-Therma Split 10 12
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,800 kg

Certification Date
01.06.2023
Testing basis
HP KEYMARK certification scheme rules V11
Generate PDF Export model CSV
  • Number of models 4

Models

AHW-100HCDS1/AHM-100HCDSAA
Configure model
Model name
AHW-100HCDS1/AHM-100HCDSAA
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.05 kW

9.10 kW

El input

1.99 kW

2.92 kW

COP

5.05

3.11

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

140 %

Prated

8.52 kW

8.00 kW

SCOP

4.83

3.58

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.54 kW

7.08 kW

COP Tj = -7°C

3.02

2.18

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.57 kW

4.29 kW

COP Tj = +2°C

4.83

3.44

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.88 kW

2.89 kW

COP Tj = +7°C

6.54

4.83

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.58 kW

2.67 kW

COP Tj = 12°C

6.06

6.75

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.54 kW

7.08 kW

COP Tj = Tbiv

3.02

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.91 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.79

1.73

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

5 W

5 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.32 kW

0.09 kW

Annual energy consumption Qhe

3645 kWh

4619 kWh

AHW-100HEDS1/AHM-100HEDSAA
Configure model
Model name
AHW-100HEDS1/AHM-100HEDSAA
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.05 kW

9.10 kW

El input

1.99 kW

2.92 kW

COP

5.05

3.11

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

140 %

Prated

8.57 kW

8.02 kW

SCOP

4.83

3.58

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.58 kW

7.09 kW

COP Tj = -7°C

3.03

2.19

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.57 kW

4.29 kW

COP Tj = +2°C

4.83

3.44

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.89 kW

2.89 kW

COP Tj = +7°C

6.55

4.84

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.58 kW

2.67 kW

COP Tj = 12°C

6.06

6.75

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.58 kW

7.09 kW

COP Tj = Tbiv

3.03

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.91 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.79

1.74

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

5 W

5 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.37 kW

0.11 kW

Annual energy consumption Qhe

3666 kWh

4623 kWh

AHW-120HCDS1/AHM-120HCDSAA
Configure model
Model name
AHW-120HCDS1/AHM-120HCDSAA
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.05 kW

11.22 kW

El input

2.47 kW

3.67 kW

COP

4.87

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

135 %

Prated

9.53 kW

9.11 kW

SCOP

4.76

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.43 kW

8.06 kW

COP Tj = -7°C

3.15

2.11

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.11 kW

4.78 kW

COP Tj = +2°C

4.52

3.27

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.21 kW

3.29 kW

COP Tj = +7°C

6.44

4.89

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.51 kW

2.64 kW

COP Tj = 12°C

7.13

6.14

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.43 kW

8.06 kW

COP Tj = Tbiv

3.15

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.07 kW

8.69 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.78

1.69

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

5 W

5 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.47 kW

0.42 kW

Annual energy consumption Qhe

3900 kWh

5450 kWh

AHW-120HEDS1/AHM-120HEDSAA
Configure model
Model name
AHW-120HEDS1/AHM-120HEDSAA
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.05 kW

11.22 kW

El input

2.47 kW

3.67 kW

COP

4.88

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

135 %

Prated

9.50 kW

9.16 kW

SCOP

4.76

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.40 kW

8.10 kW

COP Tj = -7°C

3.16

2.12

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.11 kW

4.78 kW

COP Tj = +2°C

4.52

3.27

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.21 kW

3.29 kW

COP Tj = +7°C

6.45

4.87

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.51 kW

2.64 kW

COP Tj = 12°C

7.13

6.14

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.40 kW

8.10 kW

COP Tj = Tbiv

3.16

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.07 kW

8.69 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.78

1.69

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

5 W

5 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.43 kW

0.47 kW

Annual energy consumption Qhe

4121 kWh

5472 kWh