Certificate holders

Subtype

Intelligent Inverter Heat Pump R32- P17A, P17T

Certificate Holder
Guangdong PHNIX Eco-Energy Solution Ltd.
No. 3 Tianyuan Road Dagang Town
511470 Guangdong
China
Registration number
041-K020-09
Certification Body
BRE
Subtype title
Intelligent Inverter Heat Pump R32- P17A, P17T
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,000 kg

Certification Date
05.09.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 12
Testing laboratory
TÜV SÜD Certification and Testing Co., Ltd. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

P17A
Configure model
Model name
P17A
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.72 kW

20.31 kW

El input

3.68 kW

7.18 kW

COP

4.54

2.83

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

69 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

126 %

Prated

12.61 kW

12.67 kW

SCOP

4.00

3.21

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.15 kW

11.21 kW

COP Tj = -7°C

3.01

2.27

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

6.82 kW

6.91 kW

COP Tj = +2°C

3.67

2.81

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.90 kW

7.09 kW

COP Tj = +7°C

4.99

4.63

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.35 kW

7.16 kW

COP Tj = 12°C

6.50

5.76

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

11.15 kW

11.21 kW

COP Tj = Tbiv

3.01

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.66 kW

12.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.83

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

49 °C

49 °C

Poff

19 W

19 W

PTO

19 W

19 W

PSB

19 W

19 W

PCK

59 W

59 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.35 kW

Annual energy consumption Qhe

6512 kWh

8144 kWh

P17T
Configure model
Model name
P17T
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.91 kW

20.61 kW

El input

3.92 kW

7.91 kW

COP

4.32

2.61

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

67 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

158 %

125 %

Prated

12.89 kW

12.93 kW

SCOP

4.01

3.20

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.41 kW

11.43 kW

COP Tj = -7°C

2.96

2.26

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

6.94 kW

7.05 kW

COP Tj = +2°C

3.73

2.92

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

7.54 kW

7.13 kW

COP Tj = +7°C

5.03

4.16

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

8.26 kW

8.38 kW

COP Tj = 12°C

6.38

5.77

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

11.41 kW

11.43 kW

COP Tj = Tbiv

2.96

2.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.85 kW

12.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

40 W

40 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.04 kW

0.00 kW

Annual energy consumption Qhe

6634 kWh

8341 kWh