1,700 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.88 kW
9.12 kW
El input
2.43 kW
3.02 kW
COP
4.06
3.02
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
125 %
Prated
7.75 kW
8.02 kW
SCOP
4.19
3.20
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.86 kW
7.09 kW
COP Tj = -7°C
2.98
2.18
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.20 kW
4.41 kW
COP Tj = +2°C
3.87
3.05
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
2.72 kW
4.54 kW
COP Tj = +7°C
5.33
4.16
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
3.01 kW
4.83 kW
COP Tj = 12°C
7.38
5.38
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
6.86 kW
7.09 kW
COP Tj = Tbiv
2.98
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.78 kW
6.27 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.53
1.67
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
50 °C
50 °C
Poff
13 W
60 W
PTO
13 W
60 W
PSB
13 W
60 W
PCK
53 W
69 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
1.75 kW
Annual energy consumption Qhe
3824 kWh
5172 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.70 kW
9.12 kW
El input
2.18 kW
3.02 kW
COP
4.46
3.03
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
159 %
125 %
Prated
7.79 kW
7.91 kW
SCOP
4.04
3.20
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.89 kW
7.00 kW
COP Tj = -7°C
2.98
2.22
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.24 kW
4.28 kW
COP Tj = +2°C
3.72
2.94
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
4.29 kW
4.08 kW
COP Tj = +7°C
5.36
4.18
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
4.36 kW
4.73 kW
COP Tj = 12°C
5.82
5.84
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
6.89 kW
7.00 kW
COP Tj = Tbiv
2.98
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.73 kW
7.92 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.94
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
50 °C
50 °C
Poff
19 W
19 W
PTO
19 W
19 W
PSB
19 W
19 W
PCK
59 W
59 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.06 kW
0.00 kW
Annual energy consumption Qhe
3979 kWh
5106 kWh