1,740 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.10 kW
12.00 kW
El input
2.42 kW
3.85 kW
COP
5.00
3.12
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
253 %
174 %
Prated
11.00 kW
12.00 kW
SCOP
6.40
4.40
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.00 kW
12.00 kW
COP Tj = +2°C
3.62
2.27
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.10 kW
8.00 kW
COP Tj = +7°C
5.64
3.76
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.70 kW
4.30 kW
COP Tj = 12°C
8.33
5.95
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.10 kW
8.00 kW
COP Tj = Tbiv
5.64
3.76
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.62
2.27
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2326 kWh
3761 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
163 %
119 %
Prated
11.00 kW
10.00 kW
SCOP
4.15
3.05
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.20 kW
6.70 kW
COP Tj = -7°C
3.51
2.58
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.10 kW
4.00 kW
COP Tj = +2°C
5.05
3.68
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.20 kW
2.90 kW
COP Tj = +7°C
6.18
4.57
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.60 kW
3.30 kW
COP Tj = 12°C
8.19
6.59
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
9.30 kW
8.50 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.10 kW
4.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.90 kW
5.40 kW
Annual energy consumption Qhe
6746 kWh
8470 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.30
8.50
COP Tj = -15°C (if TOL<-20°C)
2.59
1.84
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
136 %
Prated
12.00 kW
12.00 kW
SCOP
4.78
3.48
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.70 kW
10.70 kW
COP Tj = -7°C
2.90
2.12
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.00 kW
6.60 kW
COP Tj = +2°C
4.53
3.29
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.60 kW
4.40 kW
COP Tj = +7°C
6.66
4.74
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.20 kW
4.00 kW
COP Tj = 12°C
8.92
7.28
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.70 kW
10.70 kW
COP Tj = Tbiv
2.90
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.40 kW
9.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.60 kW
2.10 kW
Annual energy consumption Qhe
5261 kWh
7224 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.10 kW
12.00 kW
El input
2.42 kW
3.85 kW
COP
5.00
3.12
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
253 %
174 %
Prated
11.00 kW
12.00 kW
SCOP
6.40
4.40
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.00 kW
12.00 kW
COP Tj = +2°C
3.62
2.27
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.10 kW
8.00 kW
COP Tj = +7°C
5.64
3.76
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.70 kW
4.30 kW
COP Tj = 12°C
8.33
5.95
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.10 kW
8.00 kW
COP Tj = Tbiv
5.64
3.76
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.62
2.27
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2326 kWh
3761 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
163 %
119 %
Prated
11.00 kW
10.00 kW
SCOP
4.15
3.05
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.20 kW
6.70 kW
COP Tj = -7°C
3.51
2.58
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.10 kW
4.00 kW
COP Tj = +2°C
5.05
3.68
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.20 kW
2.90 kW
COP Tj = +7°C
6.18
4.57
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.60 kW
3.30 kW
COP Tj = 12°C
8.19
6.59
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
9.30 kW
8.50 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.10 kW
4.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.90 kW
5.40 kW
Annual energy consumption Qhe
6746 kWh
8470 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.30
8.50
COP Tj = -15°C (if TOL<-20°C)
2.59
1.84
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
136 %
Prated
12.00 kW
12.00 kW
SCOP
4.78
3.48
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.70 kW
10.70 kW
COP Tj = -7°C
2.90
2.12
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.00 kW
6.60 kW
COP Tj = +2°C
4.53
3.29
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.60 kW
4.40 kW
COP Tj = +7°C
6.66
4.74
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.20 kW
4.00 kW
COP Tj = 12°C
8.92
7.28
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.70 kW
10.70 kW
COP Tj = Tbiv
2.90
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.40 kW
9.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.60 kW
2.10 kW
Annual energy consumption Qhe
5261 kWh
7224 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.10 kW
12.00 kW
El input
2.42 kW
3.85 kW
COP
5.00
3.12
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
253 %
175 %
Prated
11.00 kW
12.00 kW
SCOP
6.40
4.45
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.00 kW
12.00 kW
COP Tj = +2°C
3.62
2.27
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.20 kW
8.00 kW
COP Tj = +7°C
5.64
3.85
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.70 kW
4.30 kW
COP Tj = 12°C
8.34
5.95
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.20 kW
8.00 kW
COP Tj = Tbiv
5.64
3.85
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.62
2.27
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2325 kWh
3733 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
163 %
119 %
Prated
11.00 kW
10.00 kW
SCOP
4.15
3.05
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.20 kW
6.70 kW
COP Tj = -7°C
3.51
2.58
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.20 kW
4.00 kW
COP Tj = +2°C
5.06
3.68
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.20 kW
2.90 kW
COP Tj = +7°C
6.20
4.57
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.60 kW
3.30 kW
COP Tj = 12°C
8.19
6.59
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
9.30 kW
8.50 kW
COP Tj = Tbiv
2.59
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.10 kW
4.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.90 kW
5.30 kW
Annual energy consumption Qhe
6738 kWh
8459 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.30
8.50
COP Tj = -15°C (if TOL<-20°C)
2.59
1.89
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
138 %
Prated
12.00 kW
12.00 kW
SCOP
4.75
3.53
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.70 kW
10.70 kW
COP Tj = -7°C
2.90
2.13
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.00 kW
6.60 kW
COP Tj = +2°C
4.53
3.33
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.60 kW
4.40 kW
COP Tj = +7°C
6.65
4.88
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.20 kW
4.00 kW
COP Tj = 12°C
8.92
7.67
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.70 kW
10.70 kW
COP Tj = Tbiv
2.90
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.40 kW
10.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.60 kW
2.00 kW
Annual energy consumption Qhe
5256 kWh
7085 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.50 kW
14.00 kW
El input
3.05 kW
4.65 kW
COP
4.75
3.01
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
248 %
170 %
Prated
12.00 kW
14.00 kW
SCOP
6.28
4.33
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.00 kW
13.10 kW
COP Tj = +2°C
3.40
2.25
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.00 kW
9.00 kW
COP Tj = +7°C
5.60
3.61
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.20 kW
4.10 kW
COP Tj = 12°C
7.94
5.94
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.00 kW
9.00 kW
COP Tj = Tbiv
5.60
3.61
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
13.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.40
2.25
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.90 kW
Annual energy consumption Qhe
2638 kWh
4323 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
156 %
117 %
Prated
13.00 kW
11.00 kW
SCOP
3.98
3.00
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.20 kW
7.20 kW
COP Tj = -7°C
3.35
2.56
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.60 kW
4.20 kW
COP Tj = +2°C
4.72
3.62
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.40 kW
3.10 kW
COP Tj = +7°C
6.10
4.77
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.80 kW
3.60 kW
COP Tj = 12°C
8.00
6.40
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.60 kW
8.90 kW
COP Tj = Tbiv
2.55
1.82
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.90 kW
4.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.10
1.16
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.10 kW
6.60 kW
Annual energy consumption Qhe
8111 kWh
8975 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.60
8.90
COP Tj = -15°C (if TOL<-20°C)
2.55
1.82
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
134 %
Prated
14.00 kW
12.00 kW
SCOP
4.63
3.43
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.40 kW
10.90 kW
COP Tj = -7°C
2.80
1.99
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.50 kW
6.90 kW
COP Tj = +2°C
4.38
3.26
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.20 kW
4.50 kW
COP Tj = +7°C
6.53
4.79
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.50 kW
4.00 kW
COP Tj = 12°C
8.58
7.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.40 kW
10.90 kW
COP Tj = Tbiv
2.80
1.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.80 kW
10.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.51
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.20 kW
1.70 kW
Annual energy consumption Qhe
6238 kWh
7427 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.00 kW
16.00 kW
El input
3.54 kW
5.49 kW
COP
4.52
2.91
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
239 %
171 %
Prated
13.00 kW
14.00 kW
SCOP
6.05
4.35
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
13.00 kW
13.20 kW
COP Tj = +2°C
3.33
2.30
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.50 kW
9.00 kW
COP Tj = +7°C
5.19
3.68
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.80 kW
4.10 kW
COP Tj = 12°C
7.95
5.80
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.50 kW
9.00 kW
COP Tj = Tbiv
5.19
3.68
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.00 kW
13.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.33
2.30
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.80 kW
Annual energy consumption Qhe
2934 kWh
4329 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
156 %
121 %
Prated
14.00 kW
12.00 kW
SCOP
3.98
3.10
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
9.10 kW
7.70 kW
COP Tj = -7°C
3.30
2.61
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.00 kW
4.50 kW
COP Tj = +2°C
4.87
3.78
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.20 kW
3.20 kW
COP Tj = +7°C
6.50
4.87
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.70 kW
3.60 kW
COP Tj = 12°C
7.59
6.39
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.30 kW
9.60 kW
COP Tj = Tbiv
2.28
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.80 kW
5.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.89
1.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.20 kW
6.90 kW
Annual energy consumption Qhe
8618 kWh
9389 kWh
Pdh Tj = -15°C (if TOL<-20°C)
11.30
9.60
COP Tj = -15°C (if TOL<-20°C)
2.28
1.84
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
136 %
Prated
15.00 kW
13.00 kW
SCOP
4.55
3.48
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.40 kW
11.30 kW
COP Tj = -7°C
2.66
2.04
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
8.00 kW
7.30 kW
COP Tj = +2°C
4.33
3.31
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.40 kW
4.80 kW
COP Tj = +7°C
6.48
4.81
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.60 kW
4.00 kW
COP Tj = 12°C
8.96
7.35
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
13.40 kW
11.30 kW
COP Tj = Tbiv
2.66
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.40 kW
11.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.46
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.60 kW
1.80 kW
Annual energy consumption Qhe
6863 kWh
7593 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.00 kW
16.00 kW
El input
3.54 kW
5.49 kW
COP
4.52
2.91
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
239 %
171 %
Prated
13.00 kW
14.00 kW
SCOP
6.05
4.35
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
13.00 kW
13.20 kW
COP Tj = +2°C
3.33
2.30
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.50 kW
9.00 kW
COP Tj = +7°C
5.19
3.68
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.80 kW
4.10 kW
COP Tj = 12°C
7.95
5.80
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.50 kW
9.00 kW
COP Tj = Tbiv
5.19
3.68
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.00 kW
13.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.33
2.30
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.80 kW
Annual energy consumption Qhe
2934 kWh
4329 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
156 %
121 %
Prated
14.00 kW
12.00 kW
SCOP
3.98
3.10
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
9.10 kW
7.70 kW
COP Tj = -7°C
3.30
2.61
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.00 kW
4.50 kW
COP Tj = +2°C
4.87
3.78
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.20 kW
3.20 kW
COP Tj = +7°C
6.50
4.87
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.70 kW
3.60 kW
COP Tj = 12°C
7.59
6.39
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.30 kW
9.60 kW
COP Tj = Tbiv
2.28
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.80 kW
5.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.89
1.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.20 kW
6.90 kW
Annual energy consumption Qhe
8618 kWh
9389 kWh
Pdh Tj = -15°C (if TOL<-20°C)
11.30
9.60
COP Tj = -15°C (if TOL<-20°C)
2.28
1.84
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
136 %
Prated
15.00 kW
13.00 kW
SCOP
4.55
3.48
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.40 kW
11.30 kW
COP Tj = -7°C
2.66
2.04
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
8.00 kW
7.30 kW
COP Tj = +2°C
4.33
3.31
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.40 kW
4.80 kW
COP Tj = +7°C
6.48
4.81
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.60 kW
4.00 kW
COP Tj = 12°C
8.96
7.35
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
13.40 kW
11.30 kW
COP Tj = Tbiv
2.66
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.40 kW
11.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.46
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.60 kW
1.80 kW
Annual energy consumption Qhe
6863 kWh
7593 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.00 kW
16.00 kW
El input
3.54 kW
5.49 kW
COP
4.52
2.91
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
239 %
171 %
Prated
13.00 kW
14.00 kW
SCOP
6.05
4.35
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
13.00 kW
13.20 kW
COP Tj = +2°C
3.33
2.32
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.60 kW
9.10 kW
COP Tj = +7°C
5.20
3.70
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.80 kW
4.10 kW
COP Tj = 12°C
7.95
5.80
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.60 kW
9.10 kW
COP Tj = Tbiv
5.20
3.70
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.00 kW
13.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.33
2.32
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.80 kW
Annual energy consumption Qhe
2933 kWh
4321 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
156 %
121 %
Prated
14.00 kW
12.00 kW
SCOP
3.98
3.10
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
9.10 kW
7.80 kW
COP Tj = -7°C
3.32
2.64
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.00 kW
4.50 kW
COP Tj = +2°C
4.88
3.78
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.20 kW
3.20 kW
COP Tj = +7°C
6.50
4.87
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.70 kW
3.70 kW
COP Tj = 12°C
7.59
6.40
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.30 kW
9.60 kW
COP Tj = Tbiv
2.28
1.85
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.80 kW
5.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.89
1.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.20 kW
6.90 kW
Annual energy consumption Qhe
8597 kWh
9356 kWh
Pdh Tj = -15°C (if TOL<-20°C)
11.30
9.60
COP Tj = -15°C (if TOL<-20°C)
2.28
1.85
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
136 %
Prated
15.00 kW
13.00 kW
SCOP
4.55
3.48
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.40 kW
11.30 kW
COP Tj = -7°C
2.60
2.04
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
8.00 kW
7.30 kW
COP Tj = +2°C
4.39
3.33
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.40 kW
4.80 kW
COP Tj = +7°C
6.44
4.81
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.60 kW
4.00 kW
COP Tj = 12°C
8.92
7.36
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
13.40 kW
11.30 kW
COP Tj = Tbiv
2.60
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.40 kW
11.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.44
1.78
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.60 kW
1.70 kW
Annual energy consumption Qhe
6838 kWh
7571 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.50 kW
14.00 kW
El input
3.05 kW
4.65 kW
COP
4.75
3.01
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
248 %
170 %
Prated
12.00 kW
14.00 kW
SCOP
6.28
4.33
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.00 kW
13.10 kW
COP Tj = +2°C
3.40
2.25
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.00 kW
9.00 kW
COP Tj = +7°C
5.60
3.61
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.20 kW
4.10 kW
COP Tj = 12°C
7.94
5.94
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.00 kW
9.00 kW
COP Tj = Tbiv
5.60
3.61
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
13.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.40
2.25
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.90 kW
Annual energy consumption Qhe
2638 kWh
4323 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
156 %
117 %
Prated
13.00 kW
11.00 kW
SCOP
3.98
3.00
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.20 kW
7.20 kW
COP Tj = -7°C
3.35
2.56
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.60 kW
4.20 kW
COP Tj = +2°C
4.72
3.62
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.40 kW
3.10 kW
COP Tj = +7°C
6.10
4.77
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.80 kW
3.60 kW
COP Tj = 12°C
8.00
6.40
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.60 kW
8.90 kW
COP Tj = Tbiv
2.55
1.82
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.90 kW
4.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.10
1.16
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.10 kW
6.60 kW
Annual energy consumption Qhe
8111 kWh
8975 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.60
8.90
COP Tj = -15°C (if TOL<-20°C)
2.55
1.82
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
134 %
Prated
14.00 kW
12.00 kW
SCOP
4.63
3.43
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.40 kW
10.90 kW
COP Tj = -7°C
2.80
1.99
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.50 kW
6.90 kW
COP Tj = +2°C
4.38
3.26
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.20 kW
4.50 kW
COP Tj = +7°C
6.53
4.79
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.50 kW
4.00 kW
COP Tj = 12°C
8.58
7.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.40 kW
10.90 kW
COP Tj = Tbiv
2.80
1.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.80 kW
10.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.51
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.20 kW
1.70 kW
Annual energy consumption Qhe
6238 kWh
7427 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.50 kW
14.00 kW
El input
3.05 kW
4.65 kW
COP
4.75
3.01
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
248 %
170 %
Prated
12.00 kW
14.00 kW
SCOP
6.28
4.33
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.00 kW
13.10 kW
COP Tj = +2°C
3.41
2.25
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.00 kW
9.00 kW
COP Tj = +7°C
5.61
3.61
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.20 kW
4.10 kW
COP Tj = 12°C
7.94
5.94
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.00 kW
9.00 kW
COP Tj = Tbiv
5.61
3.61
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
13.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.41
2.25
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.90 kW
Annual energy consumption Qhe
2638 kWh
4320 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
156 %
117 %
Prated
13.00 kW
11.00 kW
SCOP
3.98
3.00
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.30 kW
7.20 kW
COP Tj = -7°C
3.36
2.56
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.70 kW
4.30 kW
COP Tj = +2°C
4.73
3.62
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.40 kW
3.10 kW
COP Tj = +7°C
6.11
4.77
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.80 kW
3.60 kW
COP Tj = 12°C
7.98
6.40
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.70 kW
8.90 kW
COP Tj = Tbiv
2.61
1.82
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.90 kW
4.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.10
1.16
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.10 kW
6.60 kW
Annual energy consumption Qhe
8082 kWh
8967 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.70
8.90
COP Tj = -15°C (if TOL<-20°C)
2.61
1.82
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
135 %
Prated
14.00 kW
12.00 kW
SCOP
4.63
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.40 kW
10.90 kW
COP Tj = -7°C
2.80
2.03
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.50 kW
7.10 kW
COP Tj = +2°C
4.40
3.35
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.10 kW
4.80 kW
COP Tj = +7°C
6.38
4.67
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.90 kW
4.00 kW
COP Tj = 12°C
9.16
7.27
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.40 kW
10.90 kW
COP Tj = Tbiv
2.80
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.90 kW
10.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.10 kW
2.00 kW
Annual energy consumption Qhe
6237 kWh
7384 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.10 kW
12.00 kW
El input
2.42 kW
3.85 kW
COP
5.00
3.12
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
253 %
175 %
Prated
11.00 kW
12.00 kW
SCOP
6.40
4.45
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.00 kW
12.00 kW
COP Tj = +2°C
3.62
2.27
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.20 kW
8.00 kW
COP Tj = +7°C
5.64
3.85
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.70 kW
4.30 kW
COP Tj = 12°C
8.34
5.95
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.20 kW
8.00 kW
COP Tj = Tbiv
5.64
3.85
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.62
2.27
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2325 kWh
3733 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
163 %
119 %
Prated
11.00 kW
10.00 kW
SCOP
4.15
3.05
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.20 kW
6.70 kW
COP Tj = -7°C
3.51
2.58
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.20 kW
4.00 kW
COP Tj = +2°C
5.06
3.68
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.20 kW
2.90 kW
COP Tj = +7°C
6.20
4.57
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.60 kW
3.30 kW
COP Tj = 12°C
8.19
6.59
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
9.30 kW
8.50 kW
COP Tj = Tbiv
2.59
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.10 kW
4.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.90 kW
5.30 kW
Annual energy consumption Qhe
6738 kWh
8459 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.30
8.50
COP Tj = -15°C (if TOL<-20°C)
2.59
1.89
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
138 %
Prated
12.00 kW
12.00 kW
SCOP
4.75
3.53
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.70 kW
10.70 kW
COP Tj = -7°C
2.90
2.13
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.00 kW
6.60 kW
COP Tj = +2°C
4.53
3.33
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.60 kW
4.40 kW
COP Tj = +7°C
6.65
4.88
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.20 kW
4.00 kW
COP Tj = 12°C
8.92
7.67
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.70 kW
10.70 kW
COP Tj = Tbiv
2.90
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.40 kW
10.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.60 kW
2.00 kW
Annual energy consumption Qhe
5256 kWh
7085 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.10 kW
12.00 kW
El input
2.42 kW
3.85 kW
COP
5.00
3.12
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
253 %
175 %
Prated
11.00 kW
12.00 kW
SCOP
6.40
4.45
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.00 kW
12.00 kW
COP Tj = +2°C
3.62
2.27
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.20 kW
8.00 kW
COP Tj = +7°C
5.64
3.85
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.70 kW
4.30 kW
COP Tj = 12°C
8.34
5.95
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.20 kW
8.00 kW
COP Tj = Tbiv
5.64
3.85
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.62
2.27
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2325 kWh
3733 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
163 %
119 %
Prated
11.00 kW
10.00 kW
SCOP
4.15
3.05
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.20 kW
6.70 kW
COP Tj = -7°C
3.51
2.58
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.20 kW
4.00 kW
COP Tj = +2°C
5.06
3.68
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.20 kW
2.90 kW
COP Tj = +7°C
6.20
4.57
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.60 kW
3.30 kW
COP Tj = 12°C
8.19
6.59
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
9.30 kW
8.50 kW
COP Tj = Tbiv
2.59
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.10 kW
4.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.90 kW
5.30 kW
Annual energy consumption Qhe
6738 kWh
8459 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.30
8.50
COP Tj = -15°C (if TOL<-20°C)
2.59
1.89
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
138 %
Prated
12.00 kW
12.00 kW
SCOP
4.75
3.53
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.70 kW
10.70 kW
COP Tj = -7°C
2.90
2.13
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.00 kW
6.60 kW
COP Tj = +2°C
4.53
3.33
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.60 kW
4.40 kW
COP Tj = +7°C
6.65
4.88
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.20 kW
4.00 kW
COP Tj = 12°C
8.92
7.67
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.70 kW
10.70 kW
COP Tj = Tbiv
2.90
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.40 kW
10.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.60 kW
2.00 kW
Annual energy consumption Qhe
5256 kWh
7085 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.10 kW
12.00 kW
El input
2.42 kW
3.85 kW
COP
5.00
3.12
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
253 %
175 %
Prated
11.00 kW
12.00 kW
SCOP
6.40
4.45
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.00 kW
12.00 kW
COP Tj = +2°C
3.62
2.27
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.20 kW
8.00 kW
COP Tj = +7°C
5.64
3.85
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.70 kW
4.30 kW
COP Tj = 12°C
8.34
5.95
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.20 kW
8.00 kW
COP Tj = Tbiv
5.64
3.85
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.62
2.27
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2325 kWh
3733 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
163 %
119 %
Prated
11.00 kW
10.00 kW
SCOP
4.15
3.05
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.20 kW
6.70 kW
COP Tj = -7°C
3.51
2.58
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.20 kW
4.00 kW
COP Tj = +2°C
5.06
3.68
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.20 kW
2.90 kW
COP Tj = +7°C
6.20
4.57
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.60 kW
3.30 kW
COP Tj = 12°C
8.19
6.59
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
9.30 kW
8.50 kW
COP Tj = Tbiv
2.59
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.10 kW
4.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.90 kW
5.30 kW
Annual energy consumption Qhe
6738 kWh
8459 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.30
8.50
COP Tj = -15°C (if TOL<-20°C)
2.59
1.89
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
138 %
Prated
12.00 kW
12.00 kW
SCOP
4.75
3.53
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.70 kW
10.70 kW
COP Tj = -7°C
2.90
2.13
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.00 kW
6.60 kW
COP Tj = +2°C
4.53
3.33
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.60 kW
4.40 kW
COP Tj = +7°C
6.65
4.88
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.20 kW
4.00 kW
COP Tj = 12°C
8.92
7.67
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.70 kW
10.70 kW
COP Tj = Tbiv
2.90
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.40 kW
10.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.60 kW
2.00 kW
Annual energy consumption Qhe
5256 kWh
7085 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.50 kW
14.00 kW
El input
3.05 kW
4.65 kW
COP
4.75
3.01
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
248 %
170 %
Prated
12.00 kW
14.00 kW
SCOP
6.28
4.33
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.00 kW
13.10 kW
COP Tj = +2°C
3.41
2.25
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.00 kW
9.00 kW
COP Tj = +7°C
5.61
3.61
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.20 kW
4.10 kW
COP Tj = 12°C
7.94
5.94
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.00 kW
9.00 kW
COP Tj = Tbiv
5.61
3.61
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
13.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.41
2.25
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.90 kW
Annual energy consumption Qhe
2638 kWh
4320 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
156 %
117 %
Prated
13.00 kW
11.00 kW
SCOP
3.98
3.00
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.30 kW
7.20 kW
COP Tj = -7°C
3.36
2.56
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.70 kW
4.30 kW
COP Tj = +2°C
4.73
3.62
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.40 kW
3.10 kW
COP Tj = +7°C
6.11
4.77
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.80 kW
3.60 kW
COP Tj = 12°C
7.98
6.40
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.70 kW
8.90 kW
COP Tj = Tbiv
2.61
1.82
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.90 kW
4.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.10
1.16
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.10 kW
6.60 kW
Annual energy consumption Qhe
8082 kWh
8967 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.70
8.90
COP Tj = -15°C (if TOL<-20°C)
2.61
1.82
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
135 %
Prated
14.00 kW
12.00 kW
SCOP
4.63
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.40 kW
10.90 kW
COP Tj = -7°C
2.80
2.03
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.50 kW
7.10 kW
COP Tj = +2°C
4.40
3.35
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.10 kW
4.80 kW
COP Tj = +7°C
6.38
4.67
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.90 kW
4.00 kW
COP Tj = 12°C
9.16
7.27
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.40 kW
10.90 kW
COP Tj = Tbiv
2.80
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.90 kW
10.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.10 kW
2.00 kW
Annual energy consumption Qhe
6237 kWh
7384 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.50 kW
14.00 kW
El input
3.05 kW
4.65 kW
COP
4.75
3.01
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
248 %
170 %
Prated
12.00 kW
14.00 kW
SCOP
6.28
4.33
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.00 kW
13.10 kW
COP Tj = +2°C
3.41
2.25
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.00 kW
9.00 kW
COP Tj = +7°C
5.61
3.61
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.20 kW
4.10 kW
COP Tj = 12°C
7.94
5.94
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.00 kW
9.00 kW
COP Tj = Tbiv
5.61
3.61
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
13.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.41
2.25
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.90 kW
Annual energy consumption Qhe
2638 kWh
4320 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
156 %
117 %
Prated
13.00 kW
11.00 kW
SCOP
3.98
3.00
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.30 kW
7.20 kW
COP Tj = -7°C
3.36
2.56
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.70 kW
4.30 kW
COP Tj = +2°C
4.73
3.62
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.40 kW
3.10 kW
COP Tj = +7°C
6.11
4.77
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.80 kW
3.60 kW
COP Tj = 12°C
7.98
6.40
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.70 kW
8.90 kW
COP Tj = Tbiv
2.61
1.82
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.90 kW
4.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.10
1.16
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.10 kW
6.60 kW
Annual energy consumption Qhe
8082 kWh
8967 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.70
8.90
COP Tj = -15°C (if TOL<-20°C)
2.61
1.82
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
135 %
Prated
14.00 kW
12.00 kW
SCOP
4.63
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.40 kW
10.90 kW
COP Tj = -7°C
2.80
2.03
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.50 kW
7.10 kW
COP Tj = +2°C
4.40
3.35
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.10 kW
4.80 kW
COP Tj = +7°C
6.38
4.67
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.90 kW
4.00 kW
COP Tj = 12°C
9.16
7.27
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.40 kW
10.90 kW
COP Tj = Tbiv
2.80
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.90 kW
10.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.10 kW
2.00 kW
Annual energy consumption Qhe
6237 kWh
7384 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.50 kW
14.00 kW
El input
3.05 kW
4.65 kW
COP
4.75
3.01
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
248 %
170 %
Prated
12.00 kW
14.00 kW
SCOP
6.28
4.33
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.00 kW
13.10 kW
COP Tj = +2°C
3.41
2.25
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.00 kW
9.00 kW
COP Tj = +7°C
5.61
3.61
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.20 kW
4.10 kW
COP Tj = 12°C
7.94
5.94
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.00 kW
9.00 kW
COP Tj = Tbiv
5.61
3.61
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
13.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.41
2.25
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.90 kW
Annual energy consumption Qhe
2638 kWh
4320 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
156 %
117 %
Prated
13.00 kW
11.00 kW
SCOP
3.98
3.00
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.30 kW
7.20 kW
COP Tj = -7°C
3.36
2.56
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.70 kW
4.30 kW
COP Tj = +2°C
4.73
3.62
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.40 kW
3.10 kW
COP Tj = +7°C
6.11
4.77
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.80 kW
3.60 kW
COP Tj = 12°C
7.98
6.40
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.70 kW
8.90 kW
COP Tj = Tbiv
2.61
1.82
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.90 kW
4.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.10
1.16
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.10 kW
6.60 kW
Annual energy consumption Qhe
8082 kWh
8967 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.70
8.90
COP Tj = -15°C (if TOL<-20°C)
2.61
1.82
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
135 %
Prated
14.00 kW
12.00 kW
SCOP
4.63
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.40 kW
10.90 kW
COP Tj = -7°C
2.80
2.03
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.50 kW
7.10 kW
COP Tj = +2°C
4.40
3.35
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.10 kW
4.80 kW
COP Tj = +7°C
6.38
4.67
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.90 kW
4.00 kW
COP Tj = 12°C
9.16
7.27
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.40 kW
10.90 kW
COP Tj = Tbiv
2.80
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.90 kW
10.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.10 kW
2.00 kW
Annual energy consumption Qhe
6237 kWh
7384 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.00 kW
16.00 kW
El input
3.54 kW
5.49 kW
COP
4.52
2.91
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
239 %
171 %
Prated
13.00 kW
14.00 kW
SCOP
6.05
4.35
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
13.00 kW
13.20 kW
COP Tj = +2°C
3.33
2.32
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.60 kW
9.10 kW
COP Tj = +7°C
5.20
3.70
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.80 kW
4.10 kW
COP Tj = 12°C
7.95
5.80
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.60 kW
9.10 kW
COP Tj = Tbiv
5.20
3.70
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.00 kW
13.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.33
2.32
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.80 kW
Annual energy consumption Qhe
2933 kWh
4321 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
156 %
121 %
Prated
14.00 kW
12.00 kW
SCOP
3.98
3.10
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
9.10 kW
7.80 kW
COP Tj = -7°C
3.32
2.64
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.00 kW
4.50 kW
COP Tj = +2°C
4.88
3.78
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.20 kW
3.20 kW
COP Tj = +7°C
6.50
4.87
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.70 kW
3.70 kW
COP Tj = 12°C
7.59
6.40
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.30 kW
9.60 kW
COP Tj = Tbiv
2.28
1.85
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.80 kW
5.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.89
1.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.20 kW
6.90 kW
Annual energy consumption Qhe
8597 kWh
9356 kWh
Pdh Tj = -15°C (if TOL<-20°C)
11.30
9.60
COP Tj = -15°C (if TOL<-20°C)
2.28
1.85
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
136 %
Prated
15.00 kW
13.00 kW
SCOP
4.55
3.48
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.40 kW
11.30 kW
COP Tj = -7°C
2.60
2.04
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
8.00 kW
7.30 kW
COP Tj = +2°C
4.39
3.33
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.40 kW
4.80 kW
COP Tj = +7°C
6.44
4.81
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.60 kW
4.00 kW
COP Tj = 12°C
8.92
7.36
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
13.40 kW
11.30 kW
COP Tj = Tbiv
2.60
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.40 kW
11.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.44
1.78
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.60 kW
1.70 kW
Annual energy consumption Qhe
6838 kWh
7571 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.00 kW
16.00 kW
El input
3.54 kW
5.49 kW
COP
4.52
2.91
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
239 %
171 %
Prated
13.00 kW
14.00 kW
SCOP
6.05
4.35
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
13.00 kW
13.20 kW
COP Tj = +2°C
3.33
2.32
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.60 kW
9.10 kW
COP Tj = +7°C
5.20
3.70
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.80 kW
4.10 kW
COP Tj = 12°C
7.95
5.80
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.60 kW
9.10 kW
COP Tj = Tbiv
5.20
3.70
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.00 kW
13.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.33
2.32
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.80 kW
Annual energy consumption Qhe
2933 kWh
4321 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
156 %
121 %
Prated
14.00 kW
12.00 kW
SCOP
3.98
3.10
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
9.10 kW
7.80 kW
COP Tj = -7°C
3.32
2.64
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.00 kW
4.50 kW
COP Tj = +2°C
4.88
3.78
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.20 kW
3.20 kW
COP Tj = +7°C
6.50
4.87
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.70 kW
3.70 kW
COP Tj = 12°C
7.59
6.40
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.30 kW
9.60 kW
COP Tj = Tbiv
2.28
1.85
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.80 kW
5.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.89
1.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.20 kW
6.90 kW
Annual energy consumption Qhe
8597 kWh
9356 kWh
Pdh Tj = -15°C (if TOL<-20°C)
11.30
9.60
COP Tj = -15°C (if TOL<-20°C)
2.28
1.85
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
136 %
Prated
15.00 kW
13.00 kW
SCOP
4.55
3.48
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.40 kW
11.30 kW
COP Tj = -7°C
2.60
2.04
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
8.00 kW
7.30 kW
COP Tj = +2°C
4.39
3.33
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.40 kW
4.80 kW
COP Tj = +7°C
6.44
4.81
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.60 kW
4.00 kW
COP Tj = 12°C
8.92
7.36
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
13.40 kW
11.30 kW
COP Tj = Tbiv
2.60
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.40 kW
11.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.44
1.78
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.60 kW
1.70 kW
Annual energy consumption Qhe
6838 kWh
7571 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.00 kW
16.00 kW
El input
3.54 kW
5.49 kW
COP
4.52
2.91
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
239 %
171 %
Prated
13.00 kW
14.00 kW
SCOP
6.05
4.35
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
13.00 kW
13.20 kW
COP Tj = +2°C
3.33
2.32
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.60 kW
9.10 kW
COP Tj = +7°C
5.20
3.70
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.80 kW
4.10 kW
COP Tj = 12°C
7.95
5.80
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.60 kW
9.10 kW
COP Tj = Tbiv
5.20
3.70
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.00 kW
13.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.33
2.32
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.80 kW
Annual energy consumption Qhe
2933 kWh
4321 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
156 %
121 %
Prated
14.00 kW
12.00 kW
SCOP
3.98
3.10
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
9.10 kW
7.80 kW
COP Tj = -7°C
3.32
2.64
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.00 kW
4.50 kW
COP Tj = +2°C
4.88
3.78
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.20 kW
3.20 kW
COP Tj = +7°C
6.50
4.87
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.70 kW
3.70 kW
COP Tj = 12°C
7.59
6.40
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.30 kW
9.60 kW
COP Tj = Tbiv
2.28
1.85
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.80 kW
5.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.89
1.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.20 kW
6.90 kW
Annual energy consumption Qhe
8597 kWh
9356 kWh
Pdh Tj = -15°C (if TOL<-20°C)
11.30
9.60
COP Tj = -15°C (if TOL<-20°C)
2.28
1.85
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
136 %
Prated
15.00 kW
13.00 kW
SCOP
4.55
3.48
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.40 kW
11.30 kW
COP Tj = -7°C
2.60
2.04
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
8.00 kW
7.30 kW
COP Tj = +2°C
4.39
3.33
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.40 kW
4.80 kW
COP Tj = +7°C
6.44
4.81
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.60 kW
4.00 kW
COP Tj = 12°C
8.92
7.36
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
13.40 kW
11.30 kW
COP Tj = Tbiv
2.60
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.40 kW
11.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.44
1.78
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.60 kW
1.70 kW
Annual energy consumption Qhe
6838 kWh
7571 kWh