0,430 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.24 kW
5.97 kW
El input
1.31 kW
1.91 kW
COP
4.76
3.12
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
1.95 kW
Cooling capacity
5.43
EER
2.79
EN 14825
+7°C/+12°C
Pdesignc
5.43 kW
SEER
4.77
Pdc Tj = 35°C
5.43 kW
EER Tj = 35°C
2.79
Cdc Tj = 35 °C
1.000
Pdc Tj = 30°C
4.15 kW
EER Tj = 30°C
4.00
Cdc Tj = 30 °C
1.000
Pdc Tj = 25°C
2.81 kW
EER Tj = 25°C
5.65
Cdc Tj = 25 °C
1.000
Pdc Tj = 20°C
2.07 kW
EER Tj = 20°C
7.40
Cdc Tj = 20 °C
0.921
Poff
22 W
PTO
0 W
PSB
28 W
PCK
0 W
Annual energy consumption Qce
683 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
57 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
133 %
Prated
5.10 kW
4.90 kW
SCOP
4.74
3.40
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.50 kW
4.40 kW
COP Tj = -7°C
2.86
2.21
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
2.70 kW
2.70 kW
COP Tj = +2°C
4.56
3.50
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
2.10 kW
1.90 kW
COP Tj = +7°C
6.55
3.85
Cdh Tj = +7 °C
0.933
0.955
Pdh Tj = 12°C
2.50 kW
2.30 kW
COP Tj = 12°C
10.27
6.09
Cdh Tj = +12 °C
0.910
0.942
Pdh Tj = Tbiv
4.50 kW
4.40 kW
COP Tj = Tbiv
2.86
2.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.20 kW
4.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.49
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
68 °C
68 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.90 kW
0.80 kW
Annual energy consumption Qhe
2239 kWh
3002 kWh