Certificate holders

Subtype

Split Type EVI DC Inverter Air to Water Heat Pump- R32- 35

Certificate Holder
AOKOL Environment Technology Co., Ltd.
No 1, building 1, No.550, Kangzhuang South Road, Zhuangqiao Street, Jiangbei District, Ningbo City, Zhejiang Province,

China
Registration number
041-K081-01
Certification Body
BRE Global Limited
Subtype title
Split Type EVI DC Inverter Air to Water Heat Pump- R32- 35
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,500 kg

Certification Date
12.01.2024
Testing basis
Heat Pump KEYMARK certification Scheme rules v13
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

ASH-35CHW/FR
Configure model
Model name
ASH-35CHW/FR
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.82 kW

10.91 kW

El input

2.61 kW

3.92 kW

COP

4.14

2.79

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

42 dB(A)

Sound power level outdoor

67 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

130 %

Prated

10.25 kW

8.91 kW

SCOP

4.47

3.31

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

9.07 kW

7.89 kW

COP Tj = -7°C

2.83

2.13

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.67 kW

4.86 kW

COP Tj = +2°C

4.64

3.25

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.80 kW

3.11 kW

COP Tj = +7°C

5.25

4.14

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.88 kW

3.28 kW

COP Tj = 12°C

8.25

6.52

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

9.07 kW

7.89 kW

COP Tj = Tbiv

2.83

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.74 kW

6.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

10 W

10 W

PTO

36 W

36 W

PSB

10 W

10 W

PCK

50 W

50 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.51 kW

2.09 kW

Annual energy consumption Qhe

4732 kWh

5555 kWh