Certificate holders

Subtype

Tri-Thermal Split series 12 14 16 kW

Certificate Holder
GD TCL Intelligent Heating & Ventilating Equipment Co., Ltd.
No. 7 Yuanlin Road,
Guangdong
China
Registration number
041-K051-02
Certification Body
BRE Global Limited
Subtype title
Tri-Thermal Split series 12 14 16 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,840 kg

Certification Date
05.06.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 12
Generate PDF Export model CSV Download certificate
  • Number of models 12

Models

Outdoor unit: THF-12S/HBpO-A, Indoor unit: SMKLd-16S/9HBp-A
Configure model
Model name
Outdoor unit: THF-12S/HBpO-A, Indoor unit: SMKLd-16S/9HBp-A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.1 kW

12 kW

El input

2.42 kW

3.85 kW

COP

5

3.12

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

253 %

174 %

Prated

11.00 kW

12.00 kW

SCOP

6.41

4.44

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.00 kW

12.00 kW

COP Tj = +2°C

3.61

2.27

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.10 kW

8.00 kW

COP Tj = +7°C

5.65

3.75

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.70 kW

4.30 kW

COP Tj = 12°C

8.34

5.95

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.10 kW

8.00 kW

COP Tj = Tbiv

5.65

3.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.10 kW

12.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.61

2.27

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2325 kWh

3762 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

163 %

119 %

Prated

11.00 kW

10.00 kW

SCOP

4.16

3.03

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.20 kW

6.70 kW

COP Tj = -7°C

3.51

2.57

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.10 kW

3.90 kW

COP Tj = +2°C

5.05

3.69

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.20 kW

2.90 kW

COP Tj = +7°C

6.19

4.57

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.60 kW

3.20 kW

COP Tj = 12°C

8.19

6.59

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

9.20 kW

8.50 kW

COP Tj = Tbiv

2.59

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.10 kW

4.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.90 kW

5.40 kW

Annual energy consumption Qhe

6747 kWh

8500 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.20

8.50

COP Tj = -15°C (if TOL<-20°C)

2.59

1.85

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

136 %

Prated

12 kW

12 kW

SCOP

4.7

3.48

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

10.7 kW

COP Tj = -7°C

2.92

2.11

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

6.8 kW

6.8 kW

COP Tj = +2°C

4.51

3.43

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

4.5 kW

4.4 kW

COP Tj = +7°C

6.36

4.57

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

4 kW

3.7 kW

COP Tj = 12°C

8.45

6.19

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

10.7 kW

10.7 kW

COP Tj = Tbiv

2.92

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.7

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.9 kW

2 kW

Annual energy consumption Qhe

5351 kWh

7213 kWh

Outdoor unit: THF-14S/HBpO-A, Indoor unit: SMKLd-16S/9HBp-A
Configure model
Model name
Outdoor unit: THF-14S/HBpO-A, Indoor unit: SMKLd-16S/9HBp-A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.5 kW

14 kW

El input

3.05 kW

4.65 kW

COP

4.75

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

249 %

170 %

Prated

12.00 kW

14.00 kW

SCOP

6.30

4.33

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.00 kW

13.00 kW

COP Tj = +2°C

3.40

2.25

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.90 kW

9.00 kW

COP Tj = +7°C

5.60

3.61

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.10 kW

4.10 kW

COP Tj = 12°C

7.94

5.93

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.90 kW

9.00 kW

COP Tj = Tbiv

5.60

3.61

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.30 kW

13.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.40

2.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

1.00 kW

Annual energy consumption Qhe

2626 kWh

4324 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

156 %

117 %

Prated

13.00 kW

11.00 kW

SCOP

3.98

3.00

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

8.20 kW

7.10 kW

COP Tj = -7°C

3.35

2.56

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.60 kW

4.20 kW

COP Tj = +2°C

4.71

3.62

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.30 kW

3.00 kW

COP Tj = +7°C

6.10

4.77

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.70 kW

3.60 kW

COP Tj = 12°C

8.00

6.40

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.60 kW

8.90 kW

COP Tj = Tbiv

2.61

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

4.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.10

1.16

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.20 kW

6.60 kW

Annual energy consumption Qhe

8095 kWh

8982 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.60

8.90

COP Tj = -15°C (if TOL<-20°C)

2.61

1.82

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

131 %

Prated

14.00 kW

12.00 kW

SCOP

4.58

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.30 kW

10.90 kW

COP Tj = -7°C

2.70

2.02

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.50 kW

7.20 kW

COP Tj = +2°C

4.46

3.22

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.10 kW

4.60 kW

COP Tj = +7°C

6.38

4.53

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.50 kW

3.40 kW

COP Tj = 12°C

7.63

6.17

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.30 kW

10.90 kW

COP Tj = Tbiv

2.70

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.80 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.78

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.20 kW

2.00 kW

Annual energy consumption Qhe

6270 kWh

7614 kWh

Outdoor unit: THF-16S/HBpO-A, Indoor unit: SMKLd-16S/9HBp-A
Configure model
Model name
Outdoor unit: THF-16S/HBpO-A, Indoor unit: SMKLd-16S/9HBp-A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16 kW

16 kW

El input

3.54 kW

5.49 kW

COP

4.52

2.91

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

239 %

171 %

Prated

13.00 kW

14.00 kW

SCOP

6.05

4.35

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.00 kW

13.20 kW

COP Tj = +2°C

3.34

2.31

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.50 kW

9.00 kW

COP Tj = +7°C

5.20

3.69

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.80 kW

4.10 kW

COP Tj = 12°C

7.95

5.80

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.50 kW

9.00 kW

COP Tj = Tbiv

5.20

3.69

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.20 kW

13.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.34

2.31

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.80 kW

Annual energy consumption Qhe

2936 kWh

4331 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

155 %

121 %

Prated

14 kW

12 kW

SCOP

3.95

3.1

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.1 kW

7.7 kW

COP Tj = -7°C

3.3

2.61

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

5 kW

4.5 kW

COP Tj = +2°C

4.88

3.79

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

3.2 kW

3.1 kW

COP Tj = +7°C

5.75

4.87

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

3.7 kW

3.6 kW

COP Tj = 12°C

7.59

6.38

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

11.3 kW

9.6 kW

COP Tj = Tbiv

2.28

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.8 kW

5.1 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.89

1.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.2 kW

6.9 kW

Annual energy consumption Qhe

8667 kWh

9388 kWh

Pdh Tj = -15°C (if TOL<-20°C)

11.3

9.6

COP Tj = -15°C (if TOL<-20°C)

2.28

1.84

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

134 %

Prated

15 kW

13 kW

SCOP

4.55

3.43

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.5 kW

11.4 kW

COP Tj = -7°C

2.7

2.05

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

8 kW

7.1 kW

COP Tj = +2°C

4.39

3.33

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

5.4 kW

4.5 kW

COP Tj = +7°C

6.33

4.62

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

4.5 kW

3.4 kW

COP Tj = 12°C

8.57

6.12

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

13.5 kW

11.4 kW

COP Tj = Tbiv

2.7

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.2 kW

11.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.37

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.8 kW

1.8 kW

Annual energy consumption Qhe

6915 kWh

7765 kWh

Outdoor unit: THF-12S/HBpO-A, Indoor unit: SMKLd-16S/6HBp-A
Configure model
Model name
Outdoor unit: THF-12S/HBpO-A, Indoor unit: SMKLd-16S/6HBp-A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.1 kW

12 kW

El input

2.42 kW

3.85 kW

COP

5

3.12

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

253 %

174 %

Prated

11 kW

12 kW

SCOP

6.41

4.44

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11 kW

12 kW

COP Tj = +2°C

3.61

2.27

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

7.1 kW

8 kW

COP Tj = +7°C

5.65

3.75

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

4.7 kW

4.3 kW

COP Tj = 12°C

8.34

5.95

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

7.1 kW

8 kW

COP Tj = Tbiv

5.65

3.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.1 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.61

2.27

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2325 kWh

3762 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

163 %

119 %

Prated

11.00 kW

10.00 kW

SCOP

4.16

3.03

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.20 kW

6.70 kW

COP Tj = -7°C

3.51

2.57

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.10 kW

3.90 kW

COP Tj = +2°C

5.05

3.69

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.20 kW

2.90 kW

COP Tj = +7°C

6.19

4.57

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.60 kW

3.20 kW

COP Tj = 12°C

8.19

6.59

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

9.20 kW

8.50 kW

COP Tj = Tbiv

2.59

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.10 kW

4.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.90 kW

5.40 kW

Annual energy consumption Qhe

6747 kWh

8500 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.20

8.50

COP Tj = -15°C (if TOL<-20°C)

2.59

1.85

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

136 %

Prated

12 kW

12 kW

SCOP

4.7

3.48

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

10.7 kW

COP Tj = -7°C

2.92

2.11

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

6.8 kW

6.8 kW

COP Tj = +2°C

4.51

3.43

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

4.5 kW

4.4 kW

COP Tj = +7°C

6.36

4.57

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

4 kW

3.7 kW

COP Tj = 12°C

8.45

6.19

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

10.7 kW

10.7 kW

COP Tj = Tbiv

2.92

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.7

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.9 kW

2 kW

Annual energy consumption Qhe

5351 kWh

7213 kWh

Outdoor unit: THF-14S/HBpO-A, Indoor unit: SMKLd-16S/6HBp-A
Configure model
Model name
Outdoor unit: THF-14S/HBpO-A, Indoor unit: SMKLd-16S/6HBp-A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.5 kW

14 kW

El input

3.05 kW

4.65 kW

COP

4.75

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

249 %

170 %

Prated

12.00 kW

14.00 kW

SCOP

6.30

4.33

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.00 kW

13.00 kW

COP Tj = +2°C

3.40

2.25

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.90 kW

9.00 kW

COP Tj = +7°C

5.60

3.61

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.10 kW

4.10 kW

COP Tj = 12°C

7.94

5.93

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.90 kW

9.00 kW

COP Tj = Tbiv

5.60

3.61

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.30 kW

13.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.40

2.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

1.00 kW

Annual energy consumption Qhe

2626 kWh

4324 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

156 %

117 %

Prated

13.00 kW

11.00 kW

SCOP

3.98

3.00

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

8.20 kW

7.10 kW

COP Tj = -7°C

3.35

2.56

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.60 kW

4.20 kW

COP Tj = +2°C

4.71

3.62

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.30 kW

3.00 kW

COP Tj = +7°C

6.10

4.77

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.70 kW

3.60 kW

COP Tj = 12°C

8.00

6.40

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.60 kW

8.90 kW

COP Tj = Tbiv

2.61

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

4.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.10

1.16

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.20 kW

6.60 kW

Annual energy consumption Qhe

8095 kWh

8982 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.60

8.90

COP Tj = -15°C (if TOL<-20°C)

2.61

1.82

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

131 %

Prated

14.00 kW

12.00 kW

SCOP

4.58

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.30 kW

10.90 kW

COP Tj = -7°C

2.70

2.02

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.50 kW

7.20 kW

COP Tj = +2°C

4.46

3.22

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.10 kW

4.60 kW

COP Tj = +7°C

6.38

4.53

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.50 kW

3.40 kW

COP Tj = 12°C

7.63

6.17

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.30 kW

10.90 kW

COP Tj = Tbiv

2.70

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.80 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.78

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.20 kW

2.00 kW

Annual energy consumption Qhe

6270 kWh

7614 kWh

Outdoor unit: THF-16S/HBpO-A, Indoor unit: SMKLd-16S/6HBp-A
Configure model
Model name
Outdoor unit: THF-16S/HBpO-A, Indoor unit: SMKLd-16S/6HBp-A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16 kW

16 kW

El input

3.54 kW

5.49 kW

COP

4.52

2.91

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

239 %

171 %

Prated

13 kW

14 kW

SCOP

6.05

4.35

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13 kW

13.2 kW

COP Tj = +2°C

3.34

2.31

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

8.5 kW

9 kW

COP Tj = +7°C

5.2

3.69

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

4.8 kW

4.1 kW

COP Tj = 12°C

7.95

5.8

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

8.5 kW

9 kW

COP Tj = Tbiv

5.2

3.69

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13 kW

13.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.34

2.31

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0.8 kW

Annual energy consumption Qhe

2936 kWh

4331 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

155 %

121 %

Prated

14 kW

12 kW

SCOP

3.95

3.1

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.1 kW

7.7 kW

COP Tj = -7°C

3.3

2.61

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

5 kW

4.5 kW

COP Tj = +2°C

4.88

3.79

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

3.2 kW

3.1 kW

COP Tj = +7°C

5.75

4.87

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

3.7 kW

3.6 kW

COP Tj = 12°C

7.59

6.38

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

11.3 kW

9.6 kW

COP Tj = Tbiv

2.28

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.8 kW

5.1 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.89

1.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.2 kW

6.9 kW

Annual energy consumption Qhe

8667 kWh

9388 kWh

Pdh Tj = -15°C (if TOL<-20°C)

11.3

9.6

COP Tj = -15°C (if TOL<-20°C)

2.28

1.84

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

134 %

Prated

15 kW

13 kW

SCOP

4.55

3.43

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.5 kW

11.4 kW

COP Tj = -7°C

2.7

2.05

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

8 kW

7.1 kW

COP Tj = +2°C

4.39

3.33

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

5.4 kW

4.5 kW

COP Tj = +7°C

6.33

4.62

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

4.5 kW

3.4 kW

COP Tj = 12°C

8.57

6.12

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

13.5 kW

11.4 kW

COP Tj = Tbiv

2.7

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.2 kW

11.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.37

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.8 kW

1.8 kW

Annual energy consumption Qhe

6915 kWh

7765 kWh

Outdoor unit: THF-12S/HBpO-A, Indoor unit: SMKLd-16D/3HBp-A
Configure model
Model name
Outdoor unit: THF-12S/HBpO-A, Indoor unit: SMKLd-16D/3HBp-A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.1 kW

12 kW

El input

2.42 kW

3.85 kW

COP

5

3.12

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

253 %

174 %

Prated

11 kW

12 kW

SCOP

6.41

4.44

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11 kW

12 kW

COP Tj = +2°C

3.61

2.27

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

7.1 kW

8 kW

COP Tj = +7°C

5.65

3.75

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

4.7 kW

4.3 kW

COP Tj = 12°C

8.34

5.95

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

7.1 kW

8 kW

COP Tj = Tbiv

5.65

3.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.1 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.61

2.27

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2325 kWh

3762 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

163 %

119 %

Prated

11.00 kW

10.00 kW

SCOP

4.16

3.03

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.20 kW

6.70 kW

COP Tj = -7°C

3.51

2.57

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.10 kW

3.90 kW

COP Tj = +2°C

5.05

3.69

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.20 kW

2.90 kW

COP Tj = +7°C

6.19

4.57

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.60 kW

3.20 kW

COP Tj = 12°C

8.19

6.59

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

9.20 kW

8.50 kW

COP Tj = Tbiv

2.59

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.10 kW

4.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.90 kW

5.40 kW

Annual energy consumption Qhe

6747 kWh

8500 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.20

8.50

COP Tj = -15°C (if TOL<-20°C)

2.59

1.85

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

136 %

Prated

12 kW

12 kW

SCOP

4.7

3.48

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

10.7 kW

COP Tj = -7°C

2.92

2.11

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

6.8 kW

6.8 kW

COP Tj = +2°C

4.51

3.43

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

4.5 kW

4.4 kW

COP Tj = +7°C

6.36

4.57

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

4 kW

3.7 kW

COP Tj = 12°C

8.45

6.19

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

10.7 kW

10.7 kW

COP Tj = Tbiv

2.92

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.7

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.9 kW

2 kW

Annual energy consumption Qhe

5351 kWh

7213 kWh

Outdoor unit: THF-14S/HBpO-A, Indoor unit: SMKLd-16D/3HBp-A
Configure model
Model name
Outdoor unit: THF-14S/HBpO-A, Indoor unit: SMKLd-16D/3HBp-A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.5 kW

14 kW

El input

3.05 kW

4.65 kW

COP

4.75

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

249 %

170 %

Prated

12.00 kW

14.00 kW

SCOP

6.30

4.33

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.00 kW

13.00 kW

COP Tj = +2°C

3.40

2.25

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.90 kW

9.00 kW

COP Tj = +7°C

5.60

3.61

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.10 kW

4.10 kW

COP Tj = 12°C

7.94

5.93

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.90 kW

9.00 kW

COP Tj = Tbiv

5.60

3.61

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.30 kW

13.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.40

2.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

1.00 kW

Annual energy consumption Qhe

2626 kWh

4324 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

156 %

117 %

Prated

13.00 kW

11.00 kW

SCOP

3.98

3.00

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

8.20 kW

7.10 kW

COP Tj = -7°C

3.35

2.56

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.60 kW

4.20 kW

COP Tj = +2°C

4.71

3.62

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.30 kW

3.00 kW

COP Tj = +7°C

6.10

4.77

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.70 kW

3.60 kW

COP Tj = 12°C

8.00

6.40

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.60 kW

8.90 kW

COP Tj = Tbiv

2.61

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

4.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.10

1.16

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.20 kW

6.60 kW

Annual energy consumption Qhe

8095 kWh

8982 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.60

8.90

COP Tj = -15°C (if TOL<-20°C)

2.61

1.82

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

131 %

Prated

14.00 kW

12.00 kW

SCOP

4.58

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.30 kW

10.90 kW

COP Tj = -7°C

2.70

2.02

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.50 kW

7.20 kW

COP Tj = +2°C

4.46

3.22

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.10 kW

4.60 kW

COP Tj = +7°C

6.38

4.53

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.50 kW

3.40 kW

COP Tj = 12°C

7.63

6.17

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.30 kW

10.90 kW

COP Tj = Tbiv

2.70

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.80 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.78

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.20 kW

2.00 kW

Annual energy consumption Qhe

6270 kWh

7614 kWh

Outdoor unit: THF-16S/HBpO-A, Indoor unit: SMKLd-16D/3HBp-A
Configure model
Model name
Outdoor unit: THF-16S/HBpO-A, Indoor unit: SMKLd-16D/3HBp-A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16 kW

16 kW

El input

3.54 kW

5.49 kW

COP

4.52

2.91

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

239 %

171 %

Prated

13 kW

14 kW

SCOP

6.05

4.35

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13 kW

13.2 kW

COP Tj = +2°C

3.34

2.31

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

8.5 kW

9 kW

COP Tj = +7°C

5.2

3.69

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

4.8 kW

4.1 kW

COP Tj = 12°C

7.95

5.8

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

8.5 kW

9 kW

COP Tj = Tbiv

5.2

3.69

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13 kW

13.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.34

2.31

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0.8 kW

Annual energy consumption Qhe

2936 kWh

4331 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

155 %

121 %

Prated

14 kW

12 kW

SCOP

3.95

3.1

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.1 kW

7.7 kW

COP Tj = -7°C

3.3

2.61

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

5 kW

4.5 kW

COP Tj = +2°C

4.88

3.79

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

3.2 kW

3.1 kW

COP Tj = +7°C

5.75

4.87

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

3.7 kW

3.6 kW

COP Tj = 12°C

7.59

6.38

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

11.3 kW

9.6 kW

COP Tj = Tbiv

2.28

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.8 kW

5.1 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.89

1.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.2 kW

6.9 kW

Annual energy consumption Qhe

8667 kWh

9388 kWh

Pdh Tj = -15°C (if TOL<-20°C)

11.3

9.6

COP Tj = -15°C (if TOL<-20°C)

2.28

1.84

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

134 %

Prated

15 kW

13 kW

SCOP

4.55

3.43

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.5 kW

11.4 kW

COP Tj = -7°C

2.7

2.05

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

8 kW

7.1 kW

COP Tj = +2°C

4.39

3.33

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

5.4 kW

4.5 kW

COP Tj = +7°C

6.33

4.62

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

4.5 kW

3.4 kW

COP Tj = 12°C

8.57

6.12

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

13.5 kW

11.4 kW

COP Tj = Tbiv

2.7

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.2 kW

11.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.37

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.8 kW

1.8 kW

Annual energy consumption Qhe

6915 kWh

7765 kWh

Outdoor unit: THF-12S/HBpO-A, Indoor unit: SMKL-16D/HBp-A
Configure model
Model name
Outdoor unit: THF-12S/HBpO-A, Indoor unit: SMKL-16D/HBp-A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.1 kW

12 kW

El input

2.42 kW

3.85 kW

COP

5

3.12

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

253 %

174 %

Prated

11 kW

12 kW

SCOP

6.41

4.44

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11 kW

12 kW

COP Tj = +2°C

3.61

2.27

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

7.1 kW

8 kW

COP Tj = +7°C

5.65

3.75

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

4.7 kW

4.3 kW

COP Tj = 12°C

8.34

5.95

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

7.1 kW

8 kW

COP Tj = Tbiv

5.65

3.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.1 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.61

2.27

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2325 kWh

3762 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

163 %

119 %

Prated

11.00 kW

10.00 kW

SCOP

4.16

3.03

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.20 kW

6.70 kW

COP Tj = -7°C

3.51

2.57

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.10 kW

3.90 kW

COP Tj = +2°C

5.05

3.69

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.20 kW

2.90 kW

COP Tj = +7°C

6.19

4.57

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.60 kW

3.20 kW

COP Tj = 12°C

8.19

6.59

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

9.20 kW

8.50 kW

COP Tj = Tbiv

2.59

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.10 kW

4.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.90 kW

5.40 kW

Annual energy consumption Qhe

6747 kWh

8500 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.20

8.50

COP Tj = -15°C (if TOL<-20°C)

2.59

1.85

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

136 %

Prated

12 kW

12 kW

SCOP

4.7

3.48

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

10.7 kW

COP Tj = -7°C

2.92

2.11

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

6.8 kW

6.8 kW

COP Tj = +2°C

4.51

3.43

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

4.5 kW

4.4 kW

COP Tj = +7°C

6.36

4.57

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

4 kW

3.7 kW

COP Tj = 12°C

8.45

6.19

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

10.7 kW

10.7 kW

COP Tj = Tbiv

2.92

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.7

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.9 kW

2 kW

Annual energy consumption Qhe

5351 kWh

7213 kWh

Outdoor unit: THF-14S/HBpO-A, Indoor unit: SMKL-16D/HBp-A
Configure model
Model name
Outdoor unit: THF-14S/HBpO-A, Indoor unit: SMKL-16D/HBp-A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.5 kW

14 kW

El input

3.05 kW

4.65 kW

COP

4.75

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

249 %

170 %

Prated

12.00 kW

14.00 kW

SCOP

6.30

4.33

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.00 kW

13.00 kW

COP Tj = +2°C

3.40

2.25

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.90 kW

9.00 kW

COP Tj = +7°C

5.60

3.61

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.10 kW

4.10 kW

COP Tj = 12°C

7.94

5.93

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.90 kW

9.00 kW

COP Tj = Tbiv

5.60

3.61

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.30 kW

13.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.40

2.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

1.00 kW

Annual energy consumption Qhe

2626 kWh

4324 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

156 %

117 %

Prated

13.00 kW

11.00 kW

SCOP

3.98

3.00

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

8.20 kW

7.10 kW

COP Tj = -7°C

3.35

2.56

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.60 kW

4.20 kW

COP Tj = +2°C

4.71

3.62

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.30 kW

3.00 kW

COP Tj = +7°C

6.10

4.77

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.70 kW

3.60 kW

COP Tj = 12°C

8.00

6.40

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.60 kW

8.90 kW

COP Tj = Tbiv

2.61

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

4.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.10

1.16

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.20 kW

6.60 kW

Annual energy consumption Qhe

8095 kWh

8982 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.60

8.90

COP Tj = -15°C (if TOL<-20°C)

2.61

1.82

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

131 %

Prated

14.00 kW

12.00 kW

SCOP

4.65

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.30 kW

10.90 kW

COP Tj = -7°C

2.70

2.02

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.50 kW

7.20 kW

COP Tj = +2°C

4.46

3.22

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.10 kW

4.60 kW

COP Tj = +7°C

6.38

4.53

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.50 kW

3.40 kW

COP Tj = 12°C

7.63

6.17

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.30 kW

10.90 kW

COP Tj = Tbiv

2.70

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.80 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.78

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.20 kW

2.00 kW

Annual energy consumption Qhe

6270 kWh

7614 kWh

Outdoor unit: THF-16S/HBpO-A, Indoor unit: SMKL-16D/HBp-A
Configure model
Model name
Outdoor unit: THF-16S/HBpO-A, Indoor unit: SMKL-16D/HBp-A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16 kW

16 kW

El input

3.54 kW

5.49 kW

COP

4.52

2.91

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

239 %

171 %

Prated

13 kW

14 kW

SCOP

6.05

4.35

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13 kW

13.2 kW

COP Tj = +2°C

3.34

2.31

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

8.5 kW

9 kW

COP Tj = +7°C

5.2

3.69

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

4.8 kW

4.1 kW

COP Tj = 12°C

7.95

5.8

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

8.5 kW

9 kW

COP Tj = Tbiv

5.2

3.69

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13 kW

13.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.34

2.31

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0.8 kW

Annual energy consumption Qhe

2936 kWh

4331 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

155 %

121 %

Prated

14 kW

12 kW

SCOP

3.95

3.1

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.1 kW

7.7 kW

COP Tj = -7°C

3.3

2.61

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

5 kW

4.5 kW

COP Tj = +2°C

4.88

3.79

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

3.2 kW

3.1 kW

COP Tj = +7°C

5.75

4.87

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

3.7 kW

3.6 kW

COP Tj = 12°C

7.59

6.38

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

11.3 kW

9.6 kW

COP Tj = Tbiv

2.28

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.8 kW

5.1 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.89

1.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.2 kW

6.9 kW

Annual energy consumption Qhe

8667 kWh

9388 kWh

Pdh Tj = -15°C (if TOL<-20°C)

11.3

9.6

COP Tj = -15°C (if TOL<-20°C)

2.28

1.84

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

134 %

Prated

15 kW

13 kW

SCOP

4.55

3.43

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.5 kW

11.4 kW

COP Tj = -7°C

2.7

2.05

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

8 kW

7.1 kW

COP Tj = +2°C

4.39

3.33

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

5.4 kW

4.5 kW

COP Tj = +7°C

6.33

4.62

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

4.5 kW

3.4 kW

COP Tj = 12°C

8.57

6.12

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

13.5 kW

11.4 kW

COP Tj = Tbiv

2.7

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.2 kW

11.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.37

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.8 kW

1.8 kW

Annual energy consumption Qhe

6915 kWh

7765 kWh