1,650 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.40 kW
7.50 kW
El input
1.63 kW
2.36 kW
COP
5.15
3.18
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.22 kW
1.64 kW
Cooling capacity
7.45
8.30
EER
3.35
5.05
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.40 kW
8.40 kW
SEER
5.78
8.91
Pdc Tj = 35°C
7.38 kW
8.37 kW
EER Tj = 35°C
3.39
5.09
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
5.72 kW
6.47 kW
EER Tj = 30°C
4.71
7.02
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
3.62 kW
4.31 kW
EER Tj = 25°C
6.65
10.67
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
1.64 kW
1.80 kW
EER Tj = 20°C
8.55
13.61
Cdc Tj = 20 °C
0.900
0.900
Poff
14 W
14 W
PTO
10 W
10 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
768 kWh
566 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
277 %
176 %
Prated
8.10 kW
7.60 kW
SCOP
6.96
4.43
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.56 kW
7.55 kW
COP Tj = +2°C
3.98
2.59
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.22 kW
4.86 kW
COP Tj = +7°C
6.26
3.92
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.62 kW
2.31 kW
COP Tj = 12°C
9.23
5.55
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.22 kW
4.86 kW
COP Tj = Tbiv
6.26
3.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.56 kW
7.55 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.98
2.59
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
62 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.54 kW
0.05 kW
Annual energy consumption Qhe
1551 kWh
2259 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
112 %
Prated
7.00 kW
5.80 kW
SCOP
4.28
2.83
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.46 kW
3.86 kW
COP Tj = -7°C
3.66
2.48
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.69 kW
2.21 kW
COP Tj = +2°C
5.20
3.35
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
1.65 kW
1.44 kW
COP Tj = +7°C
6.53
4.11
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.65 kW
1.46 kW
COP Tj = 12°C
7.96
5.92
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.69 kW
4.71 kW
COP Tj = Tbiv
2.83
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.06 kW
2.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.95
1.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
51 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.94 kW
3.00 kW
Annual energy consumption Qhe
3976 kWh
4950 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.69
4.71
COP Tj = -15°C (if TOL<-20°C)
2.83
1.90
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
205 %
131 %
Prated
8.10 kW
6.60 kW
SCOP
5.16
3.31
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.18 kW
5.84 kW
COP Tj = -7°C
3.35
2.16
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.65 kW
3.75 kW
COP Tj = +2°C
5.09
3.30
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.90 kW
2.42 kW
COP Tj = +7°C
6.82
4.34
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.63 kW
1.39 kW
COP Tj = 12°C
8.35
5.33
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.18 kW
5.84 kW
COP Tj = Tbiv
3.35
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.44 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.66 kW
1.70 kW
Annual energy consumption Qhe
3218 kWh
4056 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.00 kW
9.50 kW
El input
2.02 kW
3.06 kW
COP
4.95
3.10
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.52 kW
2.18 kW
Cooling capacity
8.20
9.90
EER
3.25
4.55
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
8.70 kW
10.00 kW
SEER
5.93
8.73
Pdc Tj = 35°C
8.73 kW
10.01 kW
EER Tj = 35°C
3.21
4.64
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
6.68 kW
7.71 kW
EER Tj = 30°C
4.47
6.45
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
4.26 kW
5.03 kW
EER Tj = 25°C
7.02
10.36
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
1.94 kW
2.32 kW
EER Tj = 20°C
9.54
14.98
Cdc Tj = 20 °C
0.900
0.900
Poff
14 W
14 W
PTO
10 W
10 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
880 kWh
687 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
281 %
180 %
Prated
8.60 kW
8.60 kW
SCOP
7.06
4.53
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
8.44 kW
8.06 kW
COP Tj = +2°C
3.84
2.59
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.52 kW
5.54 kW
COP Tj = +7°C
6.18
4.10
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.62 kW
2.53 kW
COP Tj = 12°C
9.04
5.82
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.52 kW
5.54 kW
COP Tj = Tbiv
6.18
4.10
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.44 kW
8.15 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.84
2.61
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
62 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.16 kW
0.45 kW
Annual energy consumption Qhe
1617 kWh
2516 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
116 %
Prated
7.70 kW
6.70 kW
SCOP
4.28
2.93
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.83 kW
4.27 kW
COP Tj = -7°C
3.60
2.54
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.94 kW
2.57 kW
COP Tj = +2°C
5.26
3.51
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
1.92 kW
1.65 kW
COP Tj = +7°C
7.08
4.37
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.65 kW
1.47 kW
COP Tj = 12°C
7.96
5.96
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.32 kW
5.47 kW
COP Tj = Tbiv
2.64
2.00
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.62 kW
2.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.97
1.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
51 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.08 kW
3.91 kW
Annual energy consumption Qhe
4423 kWh
5540 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6.32
5.47
COP Tj = -15°C (if TOL<-20°C)
2.64
2.00
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
204 %
136 %
Prated
9.20 kW
7.70 kW
SCOP
5.13
3.43
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.10 kW
6.78 kW
COP Tj = -7°C
3.23
2.24
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.18 kW
4.28 kW
COP Tj = +2°C
5.01
3.42
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.32 kW
2.77 kW
COP Tj = +7°C
7.08
4.52
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.65 kW
1.58 kW
COP Tj = 12°C
8.58
5.68
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.10 kW
6.78 kW
COP Tj = Tbiv
3.23
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.40 kW
5.38 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.96
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.80 kW
2.32 kW
Annual energy consumption Qhe
3644 kWh
4539 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.40 kW
7.50 kW
El input
1.63 kW
2.36 kW
COP
5.15
3.18
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.22 kW
1.64 kW
Cooling capacity
7.45
8.30
EER
3.35
5.05
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.40 kW
8.40 kW
SEER
5.78
8.91
Pdc Tj = 35°C
7.38 kW
8.37 kW
EER Tj = 35°C
3.39
5.09
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
5.72 kW
6.47 kW
EER Tj = 30°C
4.71
7.02
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
3.62 kW
4.31 kW
EER Tj = 25°C
6.65
10.67
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
1.64 kW
1.80 kW
EER Tj = 20°C
8.55
13.61
Cdc Tj = 20 °C
0.900
0.900
Poff
14 W
14 W
PTO
10 W
10 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
768 kWh
566 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
277 %
176 %
Prated
8.10 kW
7.60 kW
SCOP
6.96
4.43
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.56 kW
7.55 kW
COP Tj = +2°C
3.98
2.59
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.22 kW
4.86 kW
COP Tj = +7°C
6.26
3.92
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.62 kW
2.31 kW
COP Tj = 12°C
9.23
5.55
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.22 kW
4.86 kW
COP Tj = Tbiv
6.26
3.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.56 kW
7.55 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.98
2.59
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
62 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.54 kW
0.05 kW
Annual energy consumption Qhe
1551 kWh
2259 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
112 %
Prated
7.00 kW
5.80 kW
SCOP
4.28
2.83
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.46 kW
3.86 kW
COP Tj = -7°C
3.66
2.48
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.69 kW
2.21 kW
COP Tj = +2°C
5.20
3.35
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
1.65 kW
1.44 kW
COP Tj = +7°C
6.53
4.11
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.65 kW
1.46 kW
COP Tj = 12°C
7.96
5.92
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.69 kW
4.71 kW
COP Tj = Tbiv
2.83
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.06 kW
2.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.95
1.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
51 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.94 kW
3.00 kW
Annual energy consumption Qhe
3976 kWh
4950 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.69
4.71
COP Tj = -15°C (if TOL<-20°C)
2.83
1.90
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
205 %
131 %
Prated
8.10 kW
6.60 kW
SCOP
5.16
3.31
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.18 kW
5.84 kW
COP Tj = -7°C
3.35
2.16
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.65 kW
3.75 kW
COP Tj = +2°C
5.09
3.30
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.90 kW
2.42 kW
COP Tj = +7°C
6.82
4.34
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.63 kW
1.39 kW
COP Tj = 12°C
8.35
5.33
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.18 kW
5.84 kW
COP Tj = Tbiv
3.35
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.44 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.66 kW
1.70 kW
Annual energy consumption Qhe
3218 kWh
4056 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
148 %
COP
3.48
Heating up time
3:26 h:min
Standby power input
37.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
215 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
103 %
COP
2.42
Heating up time
4:56 h:min
Standby power input
53.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
215 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
125 %
COP
2.92
Heating up time
4:05 h:min
Standby power input
44.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
215 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.00 kW
9.50 kW
El input
2.02 kW
3.06 kW
COP
4.95
3.10
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.52 kW
2.18 kW
Cooling capacity
8.20
9.90
EER
3.25
4.55
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
8.70 kW
10.00 kW
SEER
5.93
8.73
Pdc Tj = 35°C
8.73 kW
10.01 kW
EER Tj = 35°C
3.21
4.64
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
6.68 kW
7.71 kW
EER Tj = 30°C
4.47
6.45
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
4.26 kW
5.03 kW
EER Tj = 25°C
7.02
10.36
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
1.94 kW
2.32 kW
EER Tj = 20°C
9.54
14.98
Cdc Tj = 20 °C
0.900
0.900
Poff
14 W
14 W
PTO
10 W
10 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
880 kWh
687 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
281 %
180 %
Prated
8.60 kW
8.60 kW
SCOP
7.06
4.53
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
8.44 kW
8.06 kW
COP Tj = +2°C
3.84
2.59
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.52 kW
5.54 kW
COP Tj = +7°C
6.18
4.10
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.62 kW
2.53 kW
COP Tj = 12°C
9.04
5.82
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.52 kW
5.54 kW
COP Tj = Tbiv
6.18
4.10
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.44 kW
8.15 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.84
2.61
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
62 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.16 kW
0.45 kW
Annual energy consumption Qhe
1617 kWh
2516 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
116 %
Prated
7.70 kW
6.70 kW
SCOP
4.28
2.93
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.83 kW
4.27 kW
COP Tj = -7°C
3.60
2.54
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.94 kW
2.57 kW
COP Tj = +2°C
5.26
3.51
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
1.92 kW
1.65 kW
COP Tj = +7°C
7.08
4.37
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.65 kW
1.47 kW
COP Tj = 12°C
7.96
5.96
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.32 kW
5.47 kW
COP Tj = Tbiv
2.64
2.00
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.62 kW
2.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.97
1.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
51 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.08 kW
3.91 kW
Annual energy consumption Qhe
4423 kWh
5540 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6.32
5.47
COP Tj = -15°C (if TOL<-20°C)
2.64
2.00
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
204 %
136 %
Prated
9.20 kW
7.70 kW
SCOP
5.13
3.43
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.10 kW
6.78 kW
COP Tj = -7°C
3.23
2.24
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.18 kW
4.28 kW
COP Tj = +2°C
5.01
3.42
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.32 kW
2.77 kW
COP Tj = +7°C
7.08
4.52
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.65 kW
1.58 kW
COP Tj = 12°C
8.58
5.68
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.10 kW
6.78 kW
COP Tj = Tbiv
3.23
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.40 kW
5.38 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.96
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.80 kW
2.32 kW
Annual energy consumption Qhe
3644 kWh
4539 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
150 %
COP
3.50
Heating up time
3:19 h:min
Standby power input
39.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
215 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
104 %
COP
2.44
Heating up time
4:46 h:min
Standby power input
56.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
215 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
126 %
COP
2.95
Heating up time
3:57 h:min
Standby power input
46.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
215 l