1,840 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.10 kW
11.90 kW
El input
2.44 kW
3.90 kW
COP
4.95
3.05
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
4.18 kW
3.04 kW
Cooling capacity
11.50
12.00
EER
2.75
3.95
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
11.30 kW
11.80 kW
SEER
4.83
7.06
Pdc Tj = 35°C
11.31 kW
11.77 kW
EER Tj = 35°C
2.61
3.87
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
8.76 kW
9.21 kW
EER Tj = 30°C
3.93
5.50
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
5.81 kW
5.74 kW
EER Tj = 25°C
5.73
8.66
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
2.63 kW
3.33 kW
EER Tj = 20°C
6.75
10.07
Cdc Tj = 20 °C
0.900
0.900
Poff
14 W
14 W
PTO
10 W
10 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
1404 kWh
1004 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
256 %
174 %
Prated
11.10 kW
12.50 kW
SCOP
6.43
4.38
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.09 kW
12.07 kW
COP Tj = +2°C
3.59
2.31
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.14 kW
8.04 kW
COP Tj = +7°C
5.87
3.86
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.55 kW
3.75 kW
COP Tj = 12°C
7.94
5.70
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.14 kW
8.04 kW
COP Tj = Tbiv
5.87
3.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.09 kW
12.07 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.59
2.31
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
62 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.01 kW
0.43 kW
Annual energy consumption Qhe
2296 kWh
3776 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
160 %
118 %
Prated
11.40 kW
10.30 kW
SCOP
4.03
2.98
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.05 kW
6.63 kW
COP Tj = -7°C
3.48
2.63
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.67 kW
4.06 kW
COP Tj = +2°C
4.96
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.14 kW
2.78 kW
COP Tj = +7°C
6.10
4.54
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.57 kW
3.33 kW
COP Tj = 12°C
7.87
6.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
9.28 kW
8.41 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.01 kW
4.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.98
1.13
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
51 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.39 kW
6.11 kW
Annual energy consumption Qhe
6871 kWh
8419 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.28
8.41
COP Tj = -15°C (if TOL<-20°C)
2.59
1.84
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
189 %
135 %
Prated
12.00 kW
11.60 kW
SCOP
4.76
3.41
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.61 kW
10.24 kW
COP Tj = -7°C
2.88
2.01
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.69 kW
6.52 kW
COP Tj = +2°C
4.65
3.44
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.44 kW
4.36 kW
COP Tj = +7°C
6.62
4.59
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.74 kW
3.29 kW
COP Tj = 12°C
8.47
6.05
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.61 kW
10.24 kW
COP Tj = Tbiv
2.88
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.74 kW
9.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
1.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.26 kW
2.50 kW
Annual energy consumption Qhe
5153 kWh
6927 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.50 kW
13.80 kW
El input
3.15 kW
4.68 kW
COP
4.60
2.95
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
4.96 kW
3.49 kW
Cooling capacity
12.40
12.90
EER
2.50
3.70
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
12.20 kW
13.30 kW
SEER
4.81
6.86
Pdc Tj = 35°C
12.19 kW
13.30 kW
EER Tj = 35°C
2.46
3.47
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
9.41 kW
10.20 kW
EER Tj = 30°C
3.85
5.26
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
6.16 kW
6.57 kW
EER Tj = 25°C
5.80
8.45
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
2.63 kW
3.33 kW
EER Tj = 20°C
6.74
10.07
Cdc Tj = 20 °C
0.900
0.900
Poff
14 W
14 W
PTO
10 W
10 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
1523 kWh
1164 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
260 %
177 %
Prated
12.10 kW
13.70 kW
SCOP
6.53
4.46
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.04 kW
13.04 kW
COP Tj = +2°C
3.44
2.20
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.78 kW
8.83 kW
COP Tj = +7°C
5.84
3.91
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.75 kW
4.08 kW
COP Tj = 12°C
8.25
5.90
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.78 kW
8.83 kW
COP Tj = Tbiv
5.84
3.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.04 kW
13.04 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.44
2.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
62 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.06 kW
0.66 kW
Annual energy consumption Qhe
2462 kWh
4088 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
160 %
119 %
Prated
12.60 kW
11.00 kW
SCOP
4.03
3.01
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.96 kW
6.89 kW
COP Tj = -7°C
3.44
2.66
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.05 kW
4.32 kW
COP Tj = +2°C
4.92
3.66
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.15 kW
3.06 kW
COP Tj = +7°C
6.11
4.72
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.57 kW
3.33 kW
COP Tj = 12°C
7.82
6.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.31 kW
8.94 kW
COP Tj = Tbiv
2.53
1.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.57 kW
4.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.92
1.13
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
51 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.03 kW
6.80 kW
Annual energy consumption Qhe
7667 kWh
8866 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.31
8.94
COP Tj = -15°C (if TOL<-20°C)
2.53
1.79
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
135 %
Prated
13.70 kW
12.08 kW
SCOP
4.66
3.41
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.14 kW
10.68 kW
COP Tj = -7°C
2.79
2.01
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.94 kW
6.86 kW
COP Tj = +2°C
4.52
3.43
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.20 kW
4.63 kW
COP Tj = +7°C
6.68
4.66
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.75 kW
3.31 kW
COP Tj = 12°C
8.52
6.13
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.14 kW
10.68 kW
COP Tj = Tbiv
2.79
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.47 kW
9.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.76
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.23 kW
2.89 kW
Annual energy consumption Qhe
6013 kWh
7202 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
15.90 kW
16.00 kW
El input
3.53 kW
5.61 kW
COP
4.50
2.85
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
5.60 kW
3.77 kW
Cooling capacity
14.00
13.60
EER
2.50
3.61
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
14.30 kW
15.40 kW
SEER
4.63
6.71
Pdc Tj = 35°C
14.31 kW
15.40 kW
EER Tj = 35°C
2.47
3.50
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
10.68 kW
11.42 kW
EER Tj = 30°C
3.63
5.14
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
6.76 kW
7.27 kW
EER Tj = 25°C
5.27
7.83
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
3.41 kW
3.40 kW
EER Tj = 20°C
7.29
10.35
Cdc Tj = 20 °C
0.900
0.900
Poff
14 W
14 W
PTO
10 W
10 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
1853 kWh
1378 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
176 %
Prated
13.10 kW
13.80 kW
SCOP
6.26
4.43
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
13.09 kW
13.38 kW
COP Tj = +2°C
3.35
2.29
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.41 kW
8.86 kW
COP Tj = +7°C
5.36
3.84
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.87 kW
4.06 kW
COP Tj = 12°C
8.11
5.86
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.41 kW
8.86 kW
COP Tj = Tbiv
5.36
3.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.09 kW
13.38 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.35
2.29
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
62 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.01 kW
0.42 kW
Annual energy consumption Qhe
2786 kWh
4112 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
158 %
122 %
Prated
13.70 kW
11.80 kW
SCOP
3.98
3.08
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.31 kW
7.64 kW
COP Tj = -7°C
3.37
2.65
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.26 kW
4.42 kW
COP Tj = +2°C
4.86
3.79
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.62 kW
2.97 kW
COP Tj = +7°C
6.49
4.81
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.34 kW
3.43 kW
COP Tj = 12°C
7.40
6.29
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.22 kW
9.61 kW
COP Tj = Tbiv
2.43
1.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.88 kW
5.21 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.97
1.23
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
51 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.82 kW
6.59 kW
Annual energy consumption Qhe
8431 kWh
9309 kWh
Pdh Tj = -15°C (if TOL<-20°C)
11.22
9.61
COP Tj = -15°C (if TOL<-20°C)
2.43
1.86
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
133 %
Prated
15.20 kW
13.00 kW
SCOP
4.58
3.36
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.45 kW
11.52 kW
COP Tj = -7°C
2.72
1.99
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
8.56 kW
7.18 kW
COP Tj = +2°C
4.41
3.34
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.70 kW
4.67 kW
COP Tj = +7°C
6.56
4.61
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.78 kW
3.31 kW
COP Tj = 12°C
8.51
6.07
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
13.45 kW
11.52 kW
COP Tj = Tbiv
2.72
1.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.52 kW
10.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.48
1.80
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.68 kW
2.67 kW
Annual energy consumption Qhe
6805 kWh
7895 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.10 kW
11.90 kW
El input
2.44 kW
3.90 kW
COP
4.95
3.05
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
4.18 kW
3.04 kW
Cooling capacity
11.50
12.00
EER
2.75
3.95
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
11.30 kW
11.80 kW
SEER
4.83
7.06
Pdc Tj = 35°C
11.31 kW
11.77 kW
EER Tj = 35°C
2.61
3.87
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
8.76 kW
9.21 kW
EER Tj = 30°C
3.93
5.50
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
5.81 kW
5.74 kW
EER Tj = 25°C
5.73
8.66
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
2.63 kW
3.33 kW
EER Tj = 20°C
6.75
10.07
Cdc Tj = 20 °C
0.900
0.900
Poff
14 W
14 W
PTO
10 W
10 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
1404 kWh
1004 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
256 %
174 %
Prated
11.10 kW
12.50 kW
SCOP
6.43
4.38
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.09 kW
12.07 kW
COP Tj = +2°C
3.59
2.31
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.14 kW
8.04 kW
COP Tj = +7°C
5.87
3.86
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.55 kW
3.75 kW
COP Tj = 12°C
7.94
5.70
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.14 kW
8.04 kW
COP Tj = Tbiv
5.87
3.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.09 kW
12.07 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.59
2.31
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
62 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.01 kW
0.43 kW
Annual energy consumption Qhe
2296 kWh
3776 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
160 %
118 %
Prated
11.40 kW
10.30 kW
SCOP
4.03
2.98
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.05 kW
6.63 kW
COP Tj = -7°C
3.48
2.63
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.67 kW
4.06 kW
COP Tj = +2°C
4.96
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.14 kW
2.78 kW
COP Tj = +7°C
6.10
4.54
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.57 kW
3.33 kW
COP Tj = 12°C
7.87
6.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
9.28 kW
8.41 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.01 kW
4.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.98
1.13
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
51 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.39 kW
6.11 kW
Annual energy consumption Qhe
6871 kWh
8419 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.28
8.41
COP Tj = -15°C (if TOL<-20°C)
2.59
1.84
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
189 %
135 %
Prated
12.00 kW
11.60 kW
SCOP
4.76
3.41
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.61 kW
10.24 kW
COP Tj = -7°C
2.88
2.01
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.69 kW
6.52 kW
COP Tj = +2°C
4.65
3.44
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.44 kW
4.36 kW
COP Tj = +7°C
6.62
4.59
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.74 kW
3.29 kW
COP Tj = 12°C
8.47
6.05
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.61 kW
10.24 kW
COP Tj = Tbiv
2.88
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.74 kW
9.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
1.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.26 kW
2.50 kW
Annual energy consumption Qhe
5153 kWh
6927 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.50 kW
13.80 kW
El input
3.15 kW
4.68 kW
COP
4.60
2.95
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
4.96 kW
3.49 kW
Cooling capacity
12.40
12.90
EER
2.50
3.70
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
12.20 kW
13.30 kW
SEER
4.81
6.86
Pdc Tj = 35°C
12.19 kW
13.30 kW
EER Tj = 35°C
2.46
3.47
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
9.41 kW
10.20 kW
EER Tj = 30°C
3.85
5.26
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
6.16 kW
6.57 kW
EER Tj = 25°C
5.80
8.45
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
2.63 kW
3.33 kW
EER Tj = 20°C
6.74
10.07
Cdc Tj = 20 °C
0.900
0.900
Poff
14 W
14 W
PTO
10 W
10 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
1523 kWh
1164 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
260 %
177 %
Prated
12.10 kW
13.70 kW
SCOP
6.53
4.46
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.04 kW
13.04 kW
COP Tj = +2°C
3.44
2.20
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.78 kW
8.83 kW
COP Tj = +7°C
5.84
3.91
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.75 kW
4.08 kW
COP Tj = 12°C
8.25
5.90
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.78 kW
8.83 kW
COP Tj = Tbiv
5.84
3.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.04 kW
13.04 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.44
2.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
62 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.06 kW
0.66 kW
Annual energy consumption Qhe
2462 kWh
4088 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
160 %
119 %
Prated
12.60 kW
11.00 kW
SCOP
4.03
3.01
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.96 kW
6.89 kW
COP Tj = -7°C
3.44
2.66
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.05 kW
4.32 kW
COP Tj = +2°C
4.92
3.66
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.15 kW
3.06 kW
COP Tj = +7°C
6.11
4.72
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.57 kW
3.33 kW
COP Tj = 12°C
7.82
6.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.31 kW
8.94 kW
COP Tj = Tbiv
2.53
1.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.57 kW
4.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.92
1.13
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
51 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.03 kW
6.80 kW
Annual energy consumption Qhe
7667 kWh
8866 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.31
8.94
COP Tj = -15°C (if TOL<-20°C)
2.53
1.79
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
135 %
Prated
13.70 kW
12.08 kW
SCOP
4.66
3.41
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.14 kW
10.68 kW
COP Tj = -7°C
2.79
2.01
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.94 kW
6.86 kW
COP Tj = +2°C
4.52
3.43
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.20 kW
4.63 kW
COP Tj = +7°C
6.68
4.66
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.75 kW
3.31 kW
COP Tj = 12°C
8.52
6.13
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.14 kW
10.68 kW
COP Tj = Tbiv
2.79
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.47 kW
9.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.76
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.23 kW
2.89 kW
Annual energy consumption Qhe
6013 kWh
7202 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
15.90 kW
16.00 kW
El input
3.53 kW
5.61 kW
COP
4.50
2.85
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
5.60 kW
3.77 kW
Cooling capacity
14.00
13.60
EER
2.50
3.61
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
14.30 kW
15.40 kW
SEER
4.63
6.71
Pdc Tj = 35°C
14.31 kW
15.40 kW
EER Tj = 35°C
2.47
3.50
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
10.68 kW
11.42 kW
EER Tj = 30°C
3.63
5.14
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
6.76 kW
7.27 kW
EER Tj = 25°C
5.27
7.83
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
3.41 kW
3.40 kW
EER Tj = 20°C
7.29
10.35
Cdc Tj = 20 °C
0.900
0.900
Poff
14 W
14 W
PTO
10 W
10 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
1853 kWh
1378 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
176 %
Prated
13.10 kW
13.80 kW
SCOP
6.26
4.43
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
13.09 kW
13.38 kW
COP Tj = +2°C
3.35
2.29
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.41 kW
8.86 kW
COP Tj = +7°C
5.36
3.84
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.87 kW
4.06 kW
COP Tj = 12°C
8.11
5.86
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.41 kW
8.86 kW
COP Tj = Tbiv
5.36
3.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.09 kW
13.38 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.35
2.29
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
62 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.01 kW
0.42 kW
Annual energy consumption Qhe
2786 kWh
4112 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
158 %
122 %
Prated
13.70 kW
11.80 kW
SCOP
3.98
3.08
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.31 kW
7.64 kW
COP Tj = -7°C
3.37
2.65
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.26 kW
4.42 kW
COP Tj = +2°C
4.86
3.79
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.62 kW
2.97 kW
COP Tj = +7°C
6.49
4.81
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.34 kW
3.43 kW
COP Tj = 12°C
7.40
6.29
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.22 kW
9.61 kW
COP Tj = Tbiv
2.43
1.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.88 kW
5.21 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.97
1.23
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
51 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.82 kW
6.59 kW
Annual energy consumption Qhe
8431 kWh
9309 kWh
Pdh Tj = -15°C (if TOL<-20°C)
11.22
9.61
COP Tj = -15°C (if TOL<-20°C)
2.43
1.86
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
133 %
Prated
15.20 kW
13.00 kW
SCOP
4.58
3.36
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.45 kW
11.52 kW
COP Tj = -7°C
2.72
1.99
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
8.56 kW
7.18 kW
COP Tj = +2°C
4.41
3.34
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.70 kW
4.67 kW
COP Tj = +7°C
6.56
4.61
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.78 kW
3.31 kW
COP Tj = 12°C
8.51
6.07
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
13.45 kW
11.52 kW
COP Tj = Tbiv
2.72
1.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.52 kW
10.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.48
1.80
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.68 kW
2.67 kW
Annual energy consumption Qhe
6805 kWh
7895 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.10 kW
11.90 kW
El input
2.44 kW
3.90 kW
COP
4.95
3.05
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
4.18 kW
3.04 kW
Cooling capacity
11.50
12.00
EER
2.75
3.95
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
11.30 kW
11.80 kW
SEER
4.83
7.06
Pdc Tj = 35°C
11.31 kW
11.77 kW
EER Tj = 35°C
2.61
3.87
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
8.76 kW
9.21 kW
EER Tj = 30°C
3.93
5.50
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
5.81 kW
5.74 kW
EER Tj = 25°C
5.73
8.66
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
2.63 kW
3.33 kW
EER Tj = 20°C
6.75
10.07
Cdc Tj = 20 °C
0.900
0.900
Poff
14 W
14 W
PTO
10 W
10 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
1404 kWh
1004 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
256 %
174 %
Prated
11.10 kW
12.50 kW
SCOP
6.43
4.38
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.09 kW
12.07 kW
COP Tj = +2°C
3.59
2.31
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.14 kW
8.04 kW
COP Tj = +7°C
5.87
3.86
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.55 kW
3.75 kW
COP Tj = 12°C
7.94
5.70
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.14 kW
8.04 kW
COP Tj = Tbiv
5.87
3.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.09 kW
12.07 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.59
2.31
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
62 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.01 kW
0.43 kW
Annual energy consumption Qhe
2296 kWh
3776 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
160 %
118 %
Prated
11.40 kW
10.30 kW
SCOP
4.03
2.98
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.05 kW
6.63 kW
COP Tj = -7°C
3.48
2.63
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.67 kW
4.06 kW
COP Tj = +2°C
4.96
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.14 kW
2.78 kW
COP Tj = +7°C
6.10
4.54
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.57 kW
3.33 kW
COP Tj = 12°C
7.87
6.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
9.28 kW
8.41 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.01 kW
4.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.98
1.13
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
51 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.39 kW
6.11 kW
Annual energy consumption Qhe
6871 kWh
8419 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.28
8.41
COP Tj = -15°C (if TOL<-20°C)
2.59
1.84
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
189 %
135 %
Prated
12.00 kW
11.60 kW
SCOP
4.76
3.41
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.61 kW
10.24 kW
COP Tj = -7°C
2.88
2.01
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.69 kW
6.52 kW
COP Tj = +2°C
4.65
3.44
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.44 kW
4.36 kW
COP Tj = +7°C
6.62
4.59
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.74 kW
3.29 kW
COP Tj = 12°C
8.47
6.05
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.61 kW
10.24 kW
COP Tj = Tbiv
2.88
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.74 kW
9.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
1.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.26 kW
2.50 kW
Annual energy consumption Qhe
5153 kWh
6927 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
150 %
COP
3.56
Heating up time
3:46 h:min
Standby power input
49.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
270 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
107 %
COP
2.55
Heating up time
5:15 h:min
Standby power input
69.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
270 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
131 %
COP
3.12
Heating up time
4:18 h:min
Standby power input
56.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
270 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.50 kW
13.80 kW
El input
3.15 kW
4.68 kW
COP
4.60
2.95
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
4.96 kW
3.49 kW
Cooling capacity
12.40
12.90
EER
2.50
3.70
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
12.20 kW
13.30 kW
SEER
4.81
6.86
Pdc Tj = 35°C
12.19 kW
13.30 kW
EER Tj = 35°C
2.46
3.47
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
9.41 kW
10.20 kW
EER Tj = 30°C
3.85
5.26
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
6.16 kW
6.57 kW
EER Tj = 25°C
5.80
8.45
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
2.63 kW
3.33 kW
EER Tj = 20°C
6.74
10.07
Cdc Tj = 20 °C
0.900
0.900
Poff
14 W
14 W
PTO
10 W
10 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
1523 kWh
1164 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
260 %
177 %
Prated
12.10 kW
13.70 kW
SCOP
6.53
4.46
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.04 kW
13.04 kW
COP Tj = +2°C
3.44
2.20
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.78 kW
8.83 kW
COP Tj = +7°C
5.84
3.91
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.75 kW
4.08 kW
COP Tj = 12°C
8.25
5.90
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.78 kW
8.83 kW
COP Tj = Tbiv
5.84
3.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.04 kW
13.04 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.44
2.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
62 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.06 kW
0.66 kW
Annual energy consumption Qhe
2462 kWh
4088 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
160 %
119 %
Prated
12.60 kW
11.00 kW
SCOP
4.03
3.01
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.96 kW
6.89 kW
COP Tj = -7°C
3.44
2.66
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.05 kW
4.32 kW
COP Tj = +2°C
4.92
3.66
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.15 kW
3.06 kW
COP Tj = +7°C
6.11
4.72
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.57 kW
3.33 kW
COP Tj = 12°C
7.82
6.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.31 kW
8.94 kW
COP Tj = Tbiv
2.53
1.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.57 kW
4.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.92
1.13
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
51 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.03 kW
6.80 kW
Annual energy consumption Qhe
7667 kWh
8866 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.31
8.94
COP Tj = -15°C (if TOL<-20°C)
2.53
1.79
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
135 %
Prated
13.70 kW
12.08 kW
SCOP
4.66
3.41
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.14 kW
10.68 kW
COP Tj = -7°C
2.79
2.01
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.94 kW
6.86 kW
COP Tj = +2°C
4.52
3.43
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.20 kW
4.63 kW
COP Tj = +7°C
6.68
4.66
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.75 kW
3.31 kW
COP Tj = 12°C
8.52
6.13
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.14 kW
10.68 kW
COP Tj = Tbiv
2.79
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.47 kW
9.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.76
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.23 kW
2.89 kW
Annual energy consumption Qhe
6013 kWh
7202 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
148 %
COP
3.51
Heating up time
3:32 h:min
Standby power input
51.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
270 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
106 %
COP
2.51
Heating up time
4:56 h:min
Standby power input
72.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
270 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
129 %
COP
3.06
Heating up time
4:03 h:min
Standby power input
59.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
270 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
15.90 kW
16.00 kW
El input
3.53 kW
5.61 kW
COP
4.50
2.85
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
5.60 kW
3.77 kW
Cooling capacity
14.00
13.60
EER
2.50
3.61
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
14.30 kW
15.40 kW
SEER
4.63
6.71
Pdc Tj = 35°C
14.31 kW
15.40 kW
EER Tj = 35°C
2.47
3.50
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
10.68 kW
11.42 kW
EER Tj = 30°C
3.63
5.14
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
6.76 kW
7.27 kW
EER Tj = 25°C
5.27
7.83
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
3.41 kW
3.40 kW
EER Tj = 20°C
7.29
10.35
Cdc Tj = 20 °C
0.900
0.900
Poff
14 W
14 W
PTO
10 W
10 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
1853 kWh
1378 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
176 %
Prated
13.10 kW
13.80 kW
SCOP
6.26
4.43
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
13.09 kW
13.38 kW
COP Tj = +2°C
3.35
2.29
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.41 kW
8.86 kW
COP Tj = +7°C
5.36
3.84
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.87 kW
4.06 kW
COP Tj = 12°C
8.11
5.86
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.41 kW
8.86 kW
COP Tj = Tbiv
5.36
3.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.09 kW
13.38 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.35
2.29
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
62 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.01 kW
0.42 kW
Annual energy consumption Qhe
2786 kWh
4112 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
158 %
122 %
Prated
13.70 kW
11.80 kW
SCOP
3.98
3.08
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.31 kW
7.64 kW
COP Tj = -7°C
3.37
2.65
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.26 kW
4.42 kW
COP Tj = +2°C
4.86
3.79
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.62 kW
2.97 kW
COP Tj = +7°C
6.49
4.81
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.34 kW
3.43 kW
COP Tj = 12°C
7.40
6.29
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.22 kW
9.61 kW
COP Tj = Tbiv
2.43
1.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.88 kW
5.21 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.97
1.23
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
51 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.82 kW
6.59 kW
Annual energy consumption Qhe
8431 kWh
9309 kWh
Pdh Tj = -15°C (if TOL<-20°C)
11.22
9.61
COP Tj = -15°C (if TOL<-20°C)
2.43
1.86
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
133 %
Prated
15.20 kW
13.00 kW
SCOP
4.58
3.36
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.45 kW
11.52 kW
COP Tj = -7°C
2.72
1.99
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
8.56 kW
7.18 kW
COP Tj = +2°C
4.41
3.34
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.70 kW
4.67 kW
COP Tj = +7°C
6.56
4.61
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.78 kW
3.31 kW
COP Tj = 12°C
8.51
6.07
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
13.45 kW
11.52 kW
COP Tj = Tbiv
2.72
1.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.52 kW
10.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.48
1.80
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.68 kW
2.67 kW
Annual energy consumption Qhe
6805 kWh
7895 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
149 %
COP
3.53
Heating up time
3:23 h:min
Standby power input
54.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
270 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
107 %
COP
2.53
Heating up time
4:43 h:min
Standby power input
76.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
270 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
131 %
COP
3.09
Heating up time
3:52 h:min
Standby power input
62.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
270 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.10 kW
11.90 kW
El input
2.44 kW
3.90 kW
COP
4.95
3.05
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
4.18 kW
3.04 kW
Cooling capacity
11.50
12.00
EER
2.75
3.95
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
11.30 kW
11.80 kW
SEER
4.83
7.06
Pdc Tj = 35°C
11.31 kW
11.77 kW
EER Tj = 35°C
2.61
3.87
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
8.76 kW
9.21 kW
EER Tj = 30°C
3.93
5.50
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
5.81 kW
5.74 kW
EER Tj = 25°C
5.73
8.66
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
2.63 kW
3.33 kW
EER Tj = 20°C
6.75
10.07
Cdc Tj = 20 °C
0.900
0.900
Poff
14 W
14 W
PTO
10 W
10 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
1404 kWh
1004 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
256 %
174 %
Prated
11.10 kW
12.50 kW
SCOP
6.43
4.38
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.09 kW
12.07 kW
COP Tj = +2°C
3.59
2.31
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.14 kW
8.04 kW
COP Tj = +7°C
5.87
3.86
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.55 kW
3.75 kW
COP Tj = 12°C
7.94
5.70
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.14 kW
8.04 kW
COP Tj = Tbiv
5.87
3.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.09 kW
12.07 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.59
2.31
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
62 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.01 kW
0.43 kW
Annual energy consumption Qhe
2296 kWh
3776 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
160 %
118 %
Prated
11.40 kW
10.30 kW
SCOP
4.03
2.98
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.05 kW
6.63 kW
COP Tj = -7°C
3.48
2.63
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.67 kW
4.06 kW
COP Tj = +2°C
4.96
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.14 kW
2.78 kW
COP Tj = +7°C
6.10
4.54
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.57 kW
3.33 kW
COP Tj = 12°C
7.87
6.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
9.28 kW
8.41 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.01 kW
4.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.98
1.13
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
51 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.39 kW
6.11 kW
Annual energy consumption Qhe
6871 kWh
8419 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.28
8.41
COP Tj = -15°C (if TOL<-20°C)
2.59
1.84
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
189 %
135 %
Prated
12.00 kW
11.60 kW
SCOP
4.76
3.41
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.61 kW
10.24 kW
COP Tj = -7°C
2.88
2.01
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.69 kW
6.52 kW
COP Tj = +2°C
4.65
3.44
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.44 kW
4.36 kW
COP Tj = +7°C
6.62
4.59
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.74 kW
3.29 kW
COP Tj = 12°C
8.47
6.05
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.61 kW
10.24 kW
COP Tj = Tbiv
2.88
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.74 kW
9.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
1.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.26 kW
2.50 kW
Annual energy consumption Qhe
5153 kWh
6927 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
150 %
COP
3.56
Heating up time
3:46 h:min
Standby power input
49.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
270 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
107 %
COP
2.55
Heating up time
5:15 h:min
Standby power input
69.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
270 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
131 %
COP
3.12
Heating up time
4:18 h:min
Standby power input
56.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
270 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.50 kW
13.80 kW
El input
3.15 kW
4.68 kW
COP
4.60
2.95
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
4.96 kW
3.49 kW
Cooling capacity
12.40
12.90
EER
2.50
3.70
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
12.20 kW
13.30 kW
SEER
4.81
6.86
Pdc Tj = 35°C
12.19 kW
13.30 kW
EER Tj = 35°C
2.46
3.47
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
9.41 kW
10.20 kW
EER Tj = 30°C
3.85
5.26
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
6.16 kW
6.57 kW
EER Tj = 25°C
5.80
8.45
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
2.63 kW
3.33 kW
EER Tj = 20°C
6.74
10.07
Cdc Tj = 20 °C
0.900
0.900
Poff
14 W
14 W
PTO
10 W
10 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
1523 kWh
1164 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
260 %
177 %
Prated
12.10 kW
13.70 kW
SCOP
6.53
4.46
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.04 kW
13.04 kW
COP Tj = +2°C
3.44
2.20
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.78 kW
8.83 kW
COP Tj = +7°C
5.84
3.91
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.75 kW
4.08 kW
COP Tj = 12°C
8.25
5.90
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.78 kW
8.83 kW
COP Tj = Tbiv
5.84
3.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.04 kW
13.04 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.44
2.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
62 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.06 kW
0.66 kW
Annual energy consumption Qhe
2462 kWh
4088 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
160 %
119 %
Prated
12.60 kW
11.00 kW
SCOP
4.03
3.01
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.96 kW
6.89 kW
COP Tj = -7°C
3.44
2.66
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.05 kW
4.32 kW
COP Tj = +2°C
4.92
3.66
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.15 kW
3.06 kW
COP Tj = +7°C
6.11
4.72
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.57 kW
3.33 kW
COP Tj = 12°C
7.82
6.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.31 kW
8.94 kW
COP Tj = Tbiv
2.53
1.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.57 kW
4.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.92
1.13
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
51 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.03 kW
6.80 kW
Annual energy consumption Qhe
7667 kWh
8866 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.31
8.94
COP Tj = -15°C (if TOL<-20°C)
2.53
1.79
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
135 %
Prated
13.70 kW
12.08 kW
SCOP
4.66
3.41
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.14 kW
10.68 kW
COP Tj = -7°C
2.79
2.01
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.94 kW
6.86 kW
COP Tj = +2°C
4.52
3.43
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.20 kW
4.63 kW
COP Tj = +7°C
6.68
4.66
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.75 kW
3.31 kW
COP Tj = 12°C
8.52
6.13
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.14 kW
10.68 kW
COP Tj = Tbiv
2.79
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.47 kW
9.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.76
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.23 kW
2.89 kW
Annual energy consumption Qhe
6013 kWh
7202 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
148 %
COP
3.51
Heating up time
3:32 h:min
Standby power input
51.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
270 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
106 %
COP
2.51
Heating up time
4:56 h:min
Standby power input
72.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
270 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
129 %
COP
3.06
Heating up time
4:03 h:min
Standby power input
59.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
270 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
15.90 kW
16.00 kW
El input
3.53 kW
5.61 kW
COP
4.50
2.85
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
5.60 kW
3.77 kW
Cooling capacity
14.00
13.60
EER
2.50
3.61
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
14.30 kW
15.40 kW
SEER
4.63
6.71
Pdc Tj = 35°C
14.31 kW
15.40 kW
EER Tj = 35°C
2.47
3.50
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
10.68 kW
11.42 kW
EER Tj = 30°C
3.63
5.14
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
6.76 kW
7.27 kW
EER Tj = 25°C
5.27
7.83
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
3.41 kW
3.40 kW
EER Tj = 20°C
7.29
10.35
Cdc Tj = 20 °C
0.900
0.900
Poff
14 W
14 W
PTO
10 W
10 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
1853 kWh
1378 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
176 %
Prated
13.10 kW
13.80 kW
SCOP
6.26
4.43
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
13.09 kW
13.38 kW
COP Tj = +2°C
3.35
2.29
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.41 kW
8.86 kW
COP Tj = +7°C
5.36
3.84
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.87 kW
4.06 kW
COP Tj = 12°C
8.11
5.86
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.41 kW
8.86 kW
COP Tj = Tbiv
5.36
3.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.09 kW
13.38 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.35
2.29
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
62 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.01 kW
0.42 kW
Annual energy consumption Qhe
2786 kWh
4112 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
158 %
122 %
Prated
13.70 kW
11.80 kW
SCOP
3.98
3.08
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.31 kW
7.64 kW
COP Tj = -7°C
3.37
2.65
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.26 kW
4.42 kW
COP Tj = +2°C
4.86
3.79
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.62 kW
2.97 kW
COP Tj = +7°C
6.49
4.81
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.34 kW
3.43 kW
COP Tj = 12°C
7.40
6.29
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.22 kW
9.61 kW
COP Tj = Tbiv
2.43
1.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.88 kW
5.21 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.97
1.23
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
51 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.82 kW
6.59 kW
Annual energy consumption Qhe
8431 kWh
9309 kWh
Pdh Tj = -15°C (if TOL<-20°C)
11.22
9.61
COP Tj = -15°C (if TOL<-20°C)
2.43
1.86
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
133 %
Prated
15.20 kW
13.00 kW
SCOP
4.58
3.36
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.45 kW
11.52 kW
COP Tj = -7°C
2.72
1.99
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
8.56 kW
7.18 kW
COP Tj = +2°C
4.41
3.34
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.70 kW
4.67 kW
COP Tj = +7°C
6.56
4.61
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.78 kW
3.31 kW
COP Tj = 12°C
8.51
6.07
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
13.45 kW
11.52 kW
COP Tj = Tbiv
2.72
1.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.52 kW
10.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.48
1.80
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.68 kW
2.67 kW
Annual energy consumption Qhe
6805 kWh
7895 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
149 %
COP
3.53
Heating up time
3:23 h:min
Standby power input
54.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
270 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
107 %
COP
2.53
Heating up time
4:43 h:min
Standby power input
76.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
270 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
131 %
COP
3.09
Heating up time
3:52 h:min
Standby power input
62.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
270 l