Tri-Thermal Split series 8 10 kW

Certificate Holder
GD TCL Intelligent Heating & Ventilating Equipment Co., Ltd.
No. 7 Yuanlin Road,
Guangdong
China
Registration number
041-K051-01
Certification Body
BRE Global Limited
Subtype title
Tri-Thermal Split series 8 10 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,650 kg

Certification Date
09.05.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 11
Generate PDF Export model CSV Download certificate
  • Number of models 6

Models

Outdoor unit: THF-10D/HBpO-A, Indoor unit: SMKLd-10D/HBp-A
Configure model
Model name
Outdoor unit: THF-10D/HBpO-A, Indoor unit: SMKLd-10D/HBp-A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.5 kW

9 kW

El input

1.98 kW

3 kW

COP

4.8

3

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

174 %

Prated

9.00 kW

8.00 kW

SCOP

6.48

4.42

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.50 kW

7.80 kW

COP Tj = +2°C

3.73

2.30

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.70 kW

5.10 kW

COP Tj = +7°C

5.81

3.83

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.40 kW

2.20 kW

COP Tj = 12°C

7.93

5.66

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.50 kW

7.80 kW

COP Tj = Tbiv

3.73

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.50 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.73

2.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

15 W

15 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1756 kWh

2386 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

160 %

110 %

Prated

8.00 kW

7.00 kW

SCOP

4.07

2.82

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.20 kW

4.30 kW

COP Tj = -7°C

3.48

2.47

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.10 kW

2.60 kW

COP Tj = +2°C

4.99

3.26

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.10 kW

1.90 kW

COP Tj = +7°C

6.19

4.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.40 kW

2.30 kW

COP Tj = 12°C

7.64

5.73

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.40 kW

5.80 kW

COP Tj = Tbiv

2.57

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.90 kW

2.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.49

1.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

15 W

15 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.10 kW

4.30 kW

Annual energy consumption Qhe

4748 kWh

6270 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.40

5.80

COP Tj = -15°C (if TOL<-20°C)

2.57

1.84

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

133 %

Prated

9.00 kW

8.00 kW

SCOP

4.87

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.90 kW

7.10 kW

COP Tj = -7°C

3.02

2.12

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.70 kW

4.20 kW

COP Tj = +2°C

4.62

3.22

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.30 kW

2.70 kW

COP Tj = +7°C

6.68

4.64

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.30 kW

2.30 kW

COP Tj = 12°C

8.97

6.86

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.90 kW

7.10 kW

COP Tj = Tbiv

3.02

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

6.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

15 W

15 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

1.90 kW

Annual energy consumption Qhe

3791 kWh

4895 kWh

Outdoor unit: THF-10D/HBpO-A, Indoor unit: SMKL-10D/HBp-A
Configure model
Model name
Outdoor unit: THF-10D/HBpO-A, Indoor unit: SMKL-10D/HBp-A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.5 kW

9 kW

El input

1.98 kW

3 kW

COP

4.8

3

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

174 %

Prated

9.00 kW

8.00 kW

SCOP

6.48

4.42

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.50 kW

7.80 kW

COP Tj = +2°C

3.73

2.30

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.70 kW

5.10 kW

COP Tj = +7°C

5.81

3.83

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.40 kW

2.20 kW

COP Tj = 12°C

7.93

5.66

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.50 kW

7.80 kW

COP Tj = Tbiv

3.73

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.50 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.73

2.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

15 W

15 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1756 kWh

2386 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

160 %

110 %

Prated

8.00 kW

7.00 kW

SCOP

4.07

2.82

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.20 kW

4.30 kW

COP Tj = -7°C

3.48

2.47

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.10 kW

2.60 kW

COP Tj = +2°C

4.99

3.26

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.10 kW

1.90 kW

COP Tj = +7°C

6.19

4.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.40 kW

2.30 kW

COP Tj = 12°C

7.64

5.73

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.40 kW

5.80 kW

COP Tj = Tbiv

2.57

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.90 kW

2.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.49

1.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

15 W

15 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.10 kW

4.30 kW

Annual energy consumption Qhe

4748 kWh

6270 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.40

5.80

COP Tj = -15°C (if TOL<-20°C)

2.57

1.84

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

133 %

Prated

9.00 kW

8.00 kW

SCOP

4.87

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.90 kW

7.10 kW

COP Tj = -7°C

3.02

2.12

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.70 kW

4.20 kW

COP Tj = +2°C

4.62

3.22

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.30 kW

2.70 kW

COP Tj = +7°C

6.68

4.64

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.30 kW

2.30 kW

COP Tj = 12°C

8.97

6.86

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.90 kW

7.10 kW

COP Tj = Tbiv

3.02

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

6.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

15 W

15 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

1.90 kW

Annual energy consumption Qhe

3791 kWh

4895 kWh

Outdoor unit: THF-10D/HBpO-A, Indoor unit: SMKLd-10S/HBp-A
Configure model
Model name
Outdoor unit: THF-10D/HBpO-A, Indoor unit: SMKLd-10S/HBp-A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.5 kW

9 kW

El input

1.98 kW

3 kW

COP

4.8

3

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

174 %

Prated

9.00 kW

8.00 kW

SCOP

6.48

4.42

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.50 kW

7.80 kW

COP Tj = +2°C

3.73

2.30

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.70 kW

5.10 kW

COP Tj = +7°C

5.81

3.83

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.40 kW

2.20 kW

COP Tj = 12°C

7.93

5.66

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.50 kW

7.80 kW

COP Tj = Tbiv

3.73

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.50 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.73

2.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

15 W

15 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1756 kWh

2386 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

160 %

110 %

Prated

8.00 kW

7.00 kW

SCOP

4.07

2.82

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.20 kW

4.30 kW

COP Tj = -7°C

3.48

2.47

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.10 kW

2.60 kW

COP Tj = +2°C

4.99

3.26

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.10 kW

1.90 kW

COP Tj = +7°C

6.19

4.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.40 kW

2.30 kW

COP Tj = 12°C

7.64

5.73

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.40 kW

5.80 kW

COP Tj = Tbiv

2.57

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.90 kW

2.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.49

1.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

15 W

15 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.10 kW

4.30 kW

Annual energy consumption Qhe

4748 kWh

6270 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.40

5.80

COP Tj = -15°C (if TOL<-20°C)

2.57

1.84

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

133 %

Prated

9.00 kW

8.00 kW

SCOP

4.87

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.90 kW

7.10 kW

COP Tj = -7°C

3.02

2.12

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.70 kW

4.20 kW

COP Tj = +2°C

4.62

3.22

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.30 kW

2.70 kW

COP Tj = +7°C

6.68

4.64

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.30 kW

2.30 kW

COP Tj = 12°C

8.97

6.86

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.90 kW

7.10 kW

COP Tj = Tbiv

3.02

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

6.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

15 W

15 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

1.90 kW

Annual energy consumption Qhe

3791 kWh

4895 kWh

Outdoor unit: THF-8D/HBpO-A, Indoor unit: SMKLd-8D/HBp-A
Configure model
Model name
Outdoor unit: THF-8D/HBpO-A, Indoor unit: SMKLd-8D/HBp-A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8 kW

7.4 kW

El input

1.6 kW

2.38 kW

COP

5

3.11

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

253 %

174 %

Prated

8.00 kW

8.00 kW

SCOP

6.41

4.42

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.90 kW

7.80 kW

COP Tj = +2°C

3.68

2.30

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.10 kW

5.10 kW

COP Tj = +7°C

5.86

3.83

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.40 kW

2.20 kW

COP Tj = 12°C

7.71

5.66

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.90 kW

7.80 kW

COP Tj = Tbiv

3.68

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.90 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.68

2.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

15 W

15 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1658 kWh

2386 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

111 %

Prated

7.00 kW

6.00 kW

SCOP

4.04

2.84

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.30 kW

3.80 kW

COP Tj = -7°C

3.58

2.39

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.70 kW

2.20 kW

COP Tj = +2°C

4.88

3.42

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.00 kW

1.90 kW

COP Tj = +7°C

5.61

4.22

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.40 kW

2.30 kW

COP Tj = 12°C

6.82

6.18

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.70 kW

4.80 kW

COP Tj = Tbiv

2.68

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.40 kW

2.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.65

1.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

15 W

15 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.60 kW

3.30 kW

Annual energy consumption Qhe

4328 kWh

5197 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

4.80

COP Tj = -15°C (if TOL<-20°C)

2.68

1.84

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

135 %

Prated

8.00 kW

7.00 kW

SCOP

4.89

3.44

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.10 kW

6.10 kW

COP Tj = -7°C

3.07

2.07

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.40 kW

3.80 kW

COP Tj = +2°C

4.62

3.33

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.90 kW

2.50 kW

COP Tj = +7°C

6.70

4.53

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.30 kW

2.30 kW

COP Tj = 12°C

8.97

6.85

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.10 kW

6.10 kW

COP Tj = Tbiv

3.07

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

6.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

15 W

15 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.40 kW

0.90 kW

Annual energy consumption Qhe

3404 kWh

4205 kWh

Outdoor unit: THF-8D/HBpO-A, Indoor unit: SMKL-8D/HBp-A
Configure model
Model name
Outdoor unit: THF-8D/HBpO-A, Indoor unit: SMKL-8D/HBp-A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8 kW

7.4 kW

El input

1.6 kW

2.38 kW

COP

5

3.11

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

253 %

174 %

Prated

8.00 kW

8.00 kW

SCOP

6.41

4.42

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.90 kW

7.80 kW

COP Tj = +2°C

3.68

2.30

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.10 kW

5.10 kW

COP Tj = +7°C

5.86

3.83

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.40 kW

2.20 kW

COP Tj = 12°C

7.71

5.66

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.90 kW

7.80 kW

COP Tj = Tbiv

3.68

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.90 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.68

2.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

15 W

15 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1658 kWh

2386 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

111 %

Prated

7.00 kW

6.00 kW

SCOP

4.04

2.84

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.30 kW

3.80 kW

COP Tj = -7°C

3.58

2.39

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.70 kW

2.20 kW

COP Tj = +2°C

4.88

3.42

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.00 kW

1.90 kW

COP Tj = +7°C

5.61

4.22

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.40 kW

2.30 kW

COP Tj = 12°C

6.82

6.18

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.70 kW

4.80 kW

COP Tj = Tbiv

2.68

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.40 kW

2.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.65

1.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

15 W

15 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.60 kW

3.30 kW

Annual energy consumption Qhe

4328 kWh

5197 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

4.80

COP Tj = -15°C (if TOL<-20°C)

2.68

1.84

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

135 %

Prated

8.00 kW

7.00 kW

SCOP

4.89

3.44

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.10 kW

6.10 kW

COP Tj = -7°C

3.07

2.07

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.40 kW

3.80 kW

COP Tj = +2°C

4.62

3.33

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.90 kW

2.50 kW

COP Tj = +7°C

6.70

4.53

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.30 kW

2.30 kW

COP Tj = 12°C

8.97

6.85

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.10 kW

6.10 kW

COP Tj = Tbiv

3.07

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

6.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

15 W

15 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.40 kW

0.90 kW

Annual energy consumption Qhe

3404 kWh

4205 kWh

Outdoor unit: THF-8D/HBpO-A, Indoor unit: SMKLd-8S/HBp-A
Configure model
Model name
Outdoor unit: THF-8D/HBpO-A, Indoor unit: SMKLd-8S/HBp-A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8 kW

7.4 kW

El input

1.6 kW

2.38 kW

COP

5

3.11

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

253 %

174 %

Prated

8.00 kW

8.00 kW

SCOP

6.41

4.42

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.90 kW

7.80 kW

COP Tj = +2°C

3.68

2.30

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.10 kW

5.10 kW

COP Tj = +7°C

5.86

3.83

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.40 kW

2.20 kW

COP Tj = 12°C

7.71

5.66

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.90 kW

7.80 kW

COP Tj = Tbiv

3.68

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.90 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.68

2.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

15 W

15 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1658 kWh

2386 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

111 %

Prated

7.00 kW

6.00 kW

SCOP

4.04

2.84

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.30 kW

3.80 kW

COP Tj = -7°C

3.58

2.39

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.70 kW

2.20 kW

COP Tj = +2°C

4.88

3.42

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.00 kW

1.90 kW

COP Tj = +7°C

5.61

4.22

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.40 kW

2.30 kW

COP Tj = 12°C

6.82

6.18

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.70 kW

4.80 kW

COP Tj = Tbiv

2.68

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.40 kW

2.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.65

1.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

15 W

15 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.60 kW

3.30 kW

Annual energy consumption Qhe

4328 kWh

5197 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

4.80

COP Tj = -15°C (if TOL<-20°C)

2.68

1.84

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

135 %

Prated

8.00 kW

7.00 kW

SCOP

4.89

3.44

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.10 kW

6.10 kW

COP Tj = -7°C

3.07

2.07

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.40 kW

3.80 kW

COP Tj = +2°C

4.62

3.33

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.90 kW

2.50 kW

COP Tj = +7°C

6.70

4.53

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.30 kW

2.30 kW

COP Tj = 12°C

8.97

6.85

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.10 kW

6.10 kW

COP Tj = Tbiv

3.07

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

6.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

15 W

15 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.40 kW

0.90 kW

Annual energy consumption Qhe

3404 kWh

4205 kWh