1,050 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.23 kW
8.12 kW
El input
1.65 kW
2.60 kW
COP
5.00
3.13
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
194 %
146 %
Prated
8.21 kW
8.35 kW
SCOP
4.93
3.72
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.27 kW
7.39 kW
COP Tj = -7°C
3.40
2.35
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.46 kW
4.51 kW
COP Tj = +2°C
4.86
3.69
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.64 kW
3.56 kW
COP Tj = +7°C
6.39
4.87
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.26 kW
4.09 kW
COP Tj = 12°C
8.01
6.83
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.27 kW
7.39 kW
COP Tj = Tbiv
3.40
2.35
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.06 kW
8.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.92
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
13 W
13 W
PTO
38 W
38 W
PSB
13 W
13 W
PCK
83 W
83 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.15 kW
0.26 kW
Annual energy consumption Qhe
3445 kWh
4634 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.99 kW
8.12 kW
El input
1.63 kW
2.60 kW
COP
4.91
3.13
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
191 %
141 %
Prated
8.20 kW
8.04 kW
SCOP
4.84
3.60
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.25 kW
7.11 kW
COP Tj = -7°C
3.31
2.33
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.45 kW
4.34 kW
COP Tj = +2°C
4.81
3.59
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.48 kW
3.43 kW
COP Tj = +7°C
6.11
4.63
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.08 kW
3.95 kW
COP Tj = 12°C
8.06
6.26
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.25 kW
7.11 kW
COP Tj = Tbiv
3.31
2.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.04 kW
7.79 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.92
2.01
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
13 W
13 W
PTO
38 W
38 W
PSB
13 W
13 W
PCK
83 W
83 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.15 kW
0.24 kW
Annual energy consumption Qhe
3497 kWh
4615 kWh