Certificate holders

Subtype

Air Source Heat Pump R290-06

Certificate Holder
SolarEast Heat Pump Ltd.
No.73 Defu Road
528325 Guangdong Province,
China
Registration number
041-K042-06
Certification Body
BRE Global Limited
Subtype title
Air Source Heat Pump R290-06
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,550 kg

Certification Date
17.05.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 11
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

BLN-006TC1
Configure model
Model name
BLN-006TC1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.07 kW

6.10 kW

El input

1.27 kW

1.95 kW

COP

4.77

3.12

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

146 %

Prated

6.08 kW

6.06 kW

SCOP

4.83

3.71

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.37 kW

5.36 kW

COP Tj = -7°C

3.09

2.33

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.40 kW

3.33 kW

COP Tj = +2°C

4.68

3.66

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.24 kW

2.17 kW

COP Tj = +7°C

6.20

4.70

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.36 kW

2.28 kW

COP Tj = 12°C

9.30

7.01

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.37 kW

5.36 kW

COP Tj = Tbiv

3.09

2.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.03 kW

5.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

30 W

30 W

PSB

10 W

10 W

PCK

42 W

42 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

0.44 kW

Annual energy consumption Qhe

2599 kWh

3372 kWh