0,550 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.07 kW
6.10 kW
El input
1.27 kW
1.95 kW
COP
4.77
3.12
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
146 %
Prated
6.08 kW
6.06 kW
SCOP
4.83
3.71
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.37 kW
5.36 kW
COP Tj = -7°C
3.09
2.33
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.40 kW
3.33 kW
COP Tj = +2°C
4.68
3.66
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.24 kW
2.17 kW
COP Tj = +7°C
6.20
4.70
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.36 kW
2.28 kW
COP Tj = 12°C
9.30
7.01
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.37 kW
5.36 kW
COP Tj = Tbiv
3.09
2.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.03 kW
5.62 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.71
2.06
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
42 W
42 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.05 kW
0.44 kW
Annual energy consumption Qhe
2599 kWh
3372 kWh