2,200 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.00 kW
11.30 kW
El input
2.65 kW
3.73 kW
COP
4.53
3.03
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
138 %
Prated
13.00 kW
12.00 kW
SCOP
4.69
3.51
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.50 kW
10.60 kW
COP Tj = -7°C
2.71
2.16
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
7.00 kW
6.50 kW
COP Tj = +2°C
4.48
3.45
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.60 kW
4.20 kW
COP Tj = +7°C
6.86
4.57
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
4.80 kW
4.40 kW
COP Tj = 12°C
8.95
6.12
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
11.50 kW
10.60 kW
COP Tj = Tbiv
2.71
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.37
1.96
WTOL
65 °C
65 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5725 kWh
7051 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
110 %
COP
2.72
Heating up time
1:30 h:min
Standby power input
62.0 W
Reference hot water temperature
52.1 °C
Mixed water at 40°C
206 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.00 kW
15.00 kW
El input
3.62 kW
5.18 kW
COP
4.42
2.90
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
138 %
Prated
16.00 kW
16.00 kW
SCOP
4.48
3.53
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
14.15 kW
14.15 kW
COP Tj = -7°C
2.65
2.06
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
8.62 kW
8.62 kW
COP Tj = +2°C
4.11
3.31
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.54 kW
5.54 kW
COP Tj = +7°C
6.86
5.23
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
5.20 kW
4.49 kW
COP Tj = 12°C
8.81
6.35
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
14.15 kW
14.15 kW
COP Tj = Tbiv
2.65
2.06
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.80 kW
14.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.37
1.82
WTOL
65 °C
65 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.20 kW
2.00 kW
Annual energy consumption Qhe
7385 kWh
9379 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
110 %
COP
2.72
Heating up time
1:30 h:min
Standby power input
62.0 W
Reference hot water temperature
52.1 °C
Mixed water at 40°C
206 l