2,600 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.40 kW
3.83 kW
El input
0.93 kW
1.37 kW
COP
4.73
2.80
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
173 %
110 %
Prated
4.00 kW
4.00 kW
SCOP
4.41
2.83
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.50 kW
3.50 kW
COP Tj = -7°C
2.80
1.96
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
2.20 kW
2.10 kW
COP Tj = +2°C
4.48
2.74
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.50 kW
2.30 kW
COP Tj = +7°C
5.82
3.43
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.30 kW
2.10 kW
COP Tj = 12°C
7.23
5.29
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
4.00 kW
3.90 kW
COP Tj = Tbiv
2.68
1.77
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.00 kW
3.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
1.77
WTOL
55 °C
55 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1911 kWh
2930 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.75
Heating up time
2:20 h:min
Standby power input
65.0 W
Reference hot water temperature
52.1 °C
Mixed water at 40°C
206 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.60 kW
4.80 kW
El input
1.47 kW
1.85 kW
COP
4.49
2.59
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
173 %
115 %
Prated
5.00 kW
4.50 kW
SCOP
4.41
2.96
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.40 kW
4.00 kW
COP Tj = -7°C
2.80
2.07
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.70 kW
2.40 kW
COP Tj = +2°C
4.38
2.85
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.60 kW
2.30 kW
COP Tj = +7°C
5.78
3.61
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.40 kW
2.10 kW
COP Tj = 12°C
7.37
5.29
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.00 kW
4.50 kW
COP Tj = Tbiv
2.76
1.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
4.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.76
1.86
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
55 °C
55 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2388 kWh
3234 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.75
Heating up time
2:20 h:min
Standby power input
65.0 W
Reference hot water temperature
52.1 °C
Mixed water at 40°C
206 l