1,400 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.00 kW
8.00 kW
El input
1.87 kW
2.73 kW
COP
4.81
2.93
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
127 %
Prated
9.00 kW
8.00 kW
SCOP
4.45
3.24
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.50 kW
7.10 kW
COP Tj = -7°C
2.64
1.76
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
4.60 kW
4.30 kW
COP Tj = +2°C
4.17
3.23
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.90 kW
2.80 kW
COP Tj = +7°C
6.53
4.62
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.70 kW
2.60 kW
COP Tj = 12°C
8.87
5.88
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
7.50 kW
7.10 kW
COP Tj = Tbiv
2.64
1.76
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.70 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.32
1.35
WTOL
65 °C
65 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.30 kW
3.10 kW
Annual energy consumption Qhe
3949 kWh
5103 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
119 %
COP
2.92
Heating up time
2:00 h:min
Standby power input
58.0 W
Reference hot water temperature
52.1 °C
Mixed water at 40°C
206 l