1,700 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.74 kW
9.92 kW
El input
2.22 kW
3.16 kW
COP
4.39
3.14
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
69 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
132 %
Prated
9.18 kW
8.86 kW
SCOP
4.58
3.38
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.12 kW
7.84 kW
COP Tj = -7°C
3.10
2.22
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.97 kW
4.79 kW
COP Tj = +2°C
4.43
3.33
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.75 kW
4.56 kW
COP Tj = +7°C
5.95
4.46
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.49 kW
5.30 kW
COP Tj = 12°C
8.99
6.34
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.12 kW
7.84 kW
COP Tj = Tbiv
3.10
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.92 kW
7.77 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.03
1.88
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
45 °C
45 °C
Poff
5 W
5 W
PTO
25 W
25 W
PSB
5 W
5 W
PCK
26 W
26 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.26 kW
1.10 kW
Annual energy consumption Qhe
4146 kWh
5424 kWh