1,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.13 kW
6.09 kW
El input
1.28 kW
1.95 kW
COP
4.80
3.13
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
42 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
239 %
179 %
Prated
6.00 kW
5.90 kW
SCOP
6.10
4.57
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.68 kW
5.58 kW
COP Tj = +2°C
3.52
2.57
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
4.19 kW
3.93 kW
COP Tj = +7°C
5.85
4.03
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
2.69 kW
2.59 kW
COP Tj = 12°C
6.91
5.61
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
5.68 kW
5.58 kW
COP Tj = Tbiv
3.52
2.57
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.68 kW
5.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.52
2.57
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
67 °C
67 °C
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
8 W
8 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1326 kWh
1737 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
42 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
169 %
119 %
Prated
7.00 kW
6.40 kW
SCOP
4.31
3.17
Tbiv
-17 °C
-17 °C
TOL
-22 °C
-17 °C
Pdh Tj = -7°C
4.38 kW
3.98 kW
COP Tj = -7°C
3.66
2.82
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
2.67 kW
2.35 kW
COP Tj = +2°C
5.22
3.63
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
2.48 kW
2.30 kW
COP Tj = +7°C
6.38
4.92
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
2.72 kW
2.70 kW
COP Tj = 12°C
6.62
6.80
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
6.15 kW
5.59 kW
COP Tj = Tbiv
2.47
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.51 kW
5.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.20
1.94
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
67 °C
67 °C
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
8 W
8 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.49 kW
6.40 kW
Annual energy consumption Qhe
4003 kWh
4984 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.55
5.22
COP Tj = -15°C (if TOL<-20°C)
2.48
1.90
Cdh Tj = -15 °C
1.000
1.000
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
42 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
141 %
Prated
6.50 kW
6.10 kW
SCOP
4.84
3.66
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.76 kW
5.46 kW
COP Tj = -7°C
3.05
2.32
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
3.57 kW
3.30 kW
COP Tj = +2°C
5.01
3.71
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
2.45 kW
2.20 kW
COP Tj = +7°C
5.79
4.30
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
2.72 kW
2.53 kW
COP Tj = 12°C
6.62
5.82
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
6.20 kW
6.07 kW
COP Tj = Tbiv
2.78
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.20 kW
6.07 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.78
2.16
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
67 °C
67 °C
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
8 W
8 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2773 kWh
3441 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.13 kW
6.09 kW
El input
1.28 kW
1.95 kW
COP
4.80
3.13
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
42 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
239 %
179 %
Prated
6.00 kW
5.90 kW
SCOP
6.10
4.57
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.68 kW
5.58 kW
COP Tj = +2°C
3.52
2.57
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
4.19 kW
3.93 kW
COP Tj = +7°C
5.85
4.03
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
2.69 kW
2.59 kW
COP Tj = 12°C
6.91
5.61
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
5.68 kW
5.58 kW
COP Tj = Tbiv
3.52
2.57
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.68 kW
5.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.52
2.57
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
67 °C
67 °C
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
8 W
8 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1326 kWh
1737 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
42 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
169 %
119 %
Prated
7.00 kW
6.40 kW
SCOP
4.31
3.17
Tbiv
-17 °C
-17 °C
TOL
-22 °C
-17 °C
Pdh Tj = -7°C
4.38 kW
3.98 kW
COP Tj = -7°C
3.66
2.82
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
2.67 kW
2.35 kW
COP Tj = +2°C
5.22
3.63
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
2.48 kW
2.30 kW
COP Tj = +7°C
6.38
4.92
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
2.72 kW
2.70 kW
COP Tj = 12°C
6.62
6.80
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
6.15 kW
5.59 kW
COP Tj = Tbiv
2.47
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.51 kW
5.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.20
1.94
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
67 °C
67 °C
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
8 W
8 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.49 kW
6.40 kW
Annual energy consumption Qhe
4003 kWh
4984 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.55
5.22
COP Tj = -15°C (if TOL<-20°C)
2.48
1.90
Cdh Tj = -15 °C
1.000
1.000
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
42 dB(A)
Sound power level outdoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
141 %
Prated
6.50 kW
6.10 kW
SCOP
4.84
3.66
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.76 kW
5.46 kW
COP Tj = -7°C
3.05
2.32
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
3.57 kW
3.30 kW
COP Tj = +2°C
5.01
3.71
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
2.45 kW
2.20 kW
COP Tj = +7°C
5.79
4.30
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
2.72 kW
2.53 kW
COP Tj = 12°C
6.62
5.82
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
6.20 kW
6.07 kW
COP Tj = Tbiv
2.78
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.20 kW
6.07 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.78
2.16
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
67 °C
67 °C
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
8 W
8 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2773 kWh
3441 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.20 kW
6.04 kW
El input
1.24 kW
1.93 kW
COP
5.01
3.12
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
43 dB(A)
44 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
238 %
163 %
Prated
6.00 kW
6.00 kW
SCOP
6.08
4.17
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.54 kW
5.57 kW
COP Tj = +2°C
3.72
2.54
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
3.95 kW
3.95 kW
COP Tj = +7°C
6.27
4.08
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
2.27 kW
2.31 kW
COP Tj = 12°C
6.40
4.59
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
5.54 kW
5.57 kW
COP Tj = Tbiv
3.72
2.54
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.54 kW
5.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.54
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
67 °C
67 °C
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
8 W
8 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1330 kWh
1934 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
43 dB(A)
44 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
166 %
117 %
Prated
7.00 kW
5.80 kW
SCOP
4.22
3.01
Tbiv
-17 °C
-17 °C
TOL
-22 °C
-17 °C
Pdh Tj = -7°C
4.41 kW
3.58 kW
COP Tj = -7°C
3.53
2.68
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.72 kW
2.08 kW
COP Tj = +2°C
5.09
3.34
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
2.12 kW
2.02 kW
COP Tj = +7°C
5.98
4.88
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
2.38 kW
2.49 kW
COP Tj = 12°C
7.18
6.76
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
6.16 kW
4.99 kW
COP Tj = Tbiv
2.52
1.93
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.06 kW
4.99 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.20
1.93
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
67 °C
67 °C
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
8 W
8 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.94 kW
5.80 kW
Annual energy consumption Qhe
4090 kWh
4759 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.92
4.96
COP Tj = -15°C (if TOL<-20°C)
2.56
2.14
Cdh Tj = -15 °C
1.000
1.000
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
43 dB(A)
44 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
191 %
138 %
Prated
6.40 kW
6.00 kW
SCOP
4.97
3.60
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.71 kW
5.38 kW
COP Tj = -7°C
3.26
2.21
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
3.74 kW
3.51 kW
COP Tj = +2°C
5.25
3.56
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
2.27 kW
2.20 kW
COP Tj = +7°C
5.55
4.54
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
2.36 kW
2.40 kW
COP Tj = 12°C
6.65
5.85
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
6.11 kW
5.88 kW
COP Tj = Tbiv
2.76
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.11 kW
5.88 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.76
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
67 °C
67 °C
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
8 W
8 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2659 kWh
3446 kWh
Heating
EN 14511-2
Medium temperature
Heat output
6.04 kW
El input
1.93 kW
COP
3.12
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Medium temperature
Sound power level indoor
0 dB(A)
Sound power level outdoor
44 dB(A)
EN 14825
Medium temperature
ηs
163 %
Prated
6.00 kW
SCOP
4.17
Tbiv
2 °C
TOL
2 °C
Pdh Tj = +2°C
5.57 kW
COP Tj = +2°C
2.54
Cdh Tj = +2 °C
1.000
Pdh Tj = +7°C
3.95 kW
COP Tj = +7°C
4.08
Cdh Tj = +7 °C
0.990
Pdh Tj = 12°C
2.31 kW
COP Tj = 12°C
4.59
Cdh Tj = +12 °C
0.980
Pdh Tj = Tbiv
5.57 kW
COP Tj = Tbiv
2.54
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
WTOL
67 °C
Poff
8 W
PTO
8 W
PSB
8 W
PCK
8 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.00 kW
Annual energy consumption Qhe
1934 kWh
Colder Climate
EN 12102-1
Medium temperature
Sound power level indoor
0 dB(A)
Sound power level outdoor
44 dB(A)
EN 14825
Medium temperature
ηs
117 %
Prated
5.80 kW
SCOP
3.01
Tbiv
-17 °C
TOL
-17 °C
Pdh Tj = -7°C
3.58 kW
COP Tj = -7°C
2.68
Cdh Tj = -7 °C
0.990
Pdh Tj = +2°C
2.08 kW
COP Tj = +2°C
3.34
Cdh Tj = +2 °C
0.990
Pdh Tj = +7°C
2.02 kW
COP Tj = +7°C
4.88
Cdh Tj = +7 °C
0.980
Pdh Tj = 12°C
2.49 kW
COP Tj = 12°C
6.76
Cdh Tj = +12 °C
0.980
Pdh Tj = Tbiv
4.99 kW
COP Tj = Tbiv
1.93
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.99 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.93
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
WTOL
67 °C
Poff
8 W
PTO
8 W
PSB
8 W
PCK
8 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
5.80 kW
Annual energy consumption Qhe
4759 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.96
COP Tj = -15°C (if TOL<-20°C)
2.14
Cdh Tj = -15 °C
1.000
Average Climate
EN 12102-1
Medium temperature
Sound power level indoor
0 dB(A)
Sound power level outdoor
44 dB(A)
EN 14825
Medium temperature
ηs
138 %
Prated
6.00 kW
SCOP
3.60
Tbiv
-10 °C
TOL
-10 °C
Pdh Tj = -7°C
5.38 kW
COP Tj = -7°C
2.21
Cdh Tj = -7 °C
1.000
Pdh Tj = +2°C
3.51 kW
COP Tj = +2°C
3.56
Cdh Tj = +2 °C
0.990
Pdh Tj = +7°C
2.20 kW
COP Tj = +7°C
4.54
Cdh Tj = +7 °C
0.980
Pdh Tj = 12°C
2.40 kW
COP Tj = 12°C
5.85
Cdh Tj = +12 °C
0.980
Pdh Tj = Tbiv
5.88 kW
COP Tj = Tbiv
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.88 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
WTOL
67 °C
Poff
8 W
PTO
8 W
PSB
8 W
PCK
8 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.00 kW
Annual energy consumption Qhe
3446 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
97 %
COP
2.30
Heating up time
2:35 h:min
Standby power input
47.4 W
Reference hot water temperature
54.5 °C
Mixed water at 40°C
264 l
Heating
EN 14511-2
Medium temperature
Heat output
6.09 kW
El input
1.95 kW
COP
3.13
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Medium temperature
Sound power level indoor
42 dB(A)
Sound power level outdoor
45 dB(A)
EN 14825
Medium temperature
ηs
179 %
Prated
5.90 kW
SCOP
4.57
Tbiv
2 °C
TOL
2 °C
Pdh Tj = +2°C
5.58 kW
COP Tj = +2°C
2.57
Cdh Tj = +2 °C
1.000
Pdh Tj = +7°C
3.93 kW
COP Tj = +7°C
4.03
Cdh Tj = +7 °C
0.990
Pdh Tj = 12°C
2.59 kW
COP Tj = 12°C
5.61
Cdh Tj = +12 °C
0.980
Pdh Tj = Tbiv
5.58 kW
COP Tj = Tbiv
2.57
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.57
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
WTOL
67 °C
Poff
8 W
PTO
8 W
PSB
8 W
PCK
8 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.00 kW
Annual energy consumption Qhe
1737 kWh
Colder Climate
EN 12102-1
Medium temperature
Sound power level indoor
42 dB(A)
Sound power level outdoor
45 dB(A)
EN 14825
Medium temperature
ηs
119 %
Prated
6.40 kW
SCOP
3.17
Tbiv
-17 °C
TOL
-17 °C
Pdh Tj = -7°C
3.98 kW
COP Tj = -7°C
2.82
Cdh Tj = -7 °C
1.000
Pdh Tj = +2°C
2.35 kW
COP Tj = +2°C
3.63
Cdh Tj = +2 °C
0.990
Pdh Tj = +7°C
2.30 kW
COP Tj = +7°C
4.92
Cdh Tj = +7 °C
0.980
Pdh Tj = 12°C
2.70 kW
COP Tj = 12°C
6.80
Cdh Tj = +12 °C
0.980
Pdh Tj = Tbiv
5.59 kW
COP Tj = Tbiv
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.94
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
WTOL
67 °C
Poff
8 W
PTO
8 W
PSB
8 W
PCK
8 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
6.40 kW
Annual energy consumption Qhe
4984 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.22
COP Tj = -15°C (if TOL<-20°C)
1.90
Cdh Tj = -15 °C
1.000
Average Climate
EN 12102-1
Medium temperature
Sound power level indoor
42 dB(A)
Sound power level outdoor
45 dB(A)
EN 14825
Medium temperature
ηs
141 %
Prated
6.10 kW
SCOP
3.66
Tbiv
-10 °C
TOL
-10 °C
Pdh Tj = -7°C
5.46 kW
COP Tj = -7°C
2.32
Cdh Tj = -7 °C
1.000
Pdh Tj = +2°C
3.30 kW
COP Tj = +2°C
3.71
Cdh Tj = +2 °C
0.990
Pdh Tj = +7°C
2.20 kW
COP Tj = +7°C
4.30
Cdh Tj = +7 °C
0.980
Pdh Tj = 12°C
2.53 kW
COP Tj = 12°C
5.82
Cdh Tj = +12 °C
0.980
Pdh Tj = Tbiv
6.07 kW
COP Tj = Tbiv
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.07 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
WTOL
67 °C
Poff
8 W
PTO
8 W
PSB
8 W
PCK
8 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.00 kW
Annual energy consumption Qhe
3441 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
96 %
COP
2.30
Heating up time
2:18 h:min
Standby power input
41.0 W
Reference hot water temperature
54.4 °C
Mixed water at 40°C
255 l
Heating
EN 14511-2
Medium temperature
Heat output
6.09 kW
El input
1.95 kW
COP
3.13
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Medium temperature
Sound power level indoor
42 dB(A)
Sound power level outdoor
45 dB(A)
EN 14825
Medium temperature
ηs
179 %
Prated
5.90 kW
SCOP
4.57
Tbiv
2 °C
TOL
2 °C
Pdh Tj = +2°C
5.58 kW
COP Tj = +2°C
2.57
Cdh Tj = +2 °C
1.000
Pdh Tj = +7°C
3.93 kW
COP Tj = +7°C
4.03
Cdh Tj = +7 °C
0.990
Pdh Tj = 12°C
2.59 kW
COP Tj = 12°C
5.61
Cdh Tj = +12 °C
0.980
Pdh Tj = Tbiv
5.58 kW
COP Tj = Tbiv
2.57
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.57
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
WTOL
67 °C
Poff
8 W
PTO
8 W
PSB
8 W
PCK
8 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.00 kW
Annual energy consumption Qhe
1737 kWh
Colder Climate
EN 12102-1
Medium temperature
Sound power level indoor
42 dB(A)
Sound power level outdoor
45 dB(A)
EN 14825
Medium temperature
ηs
119 %
Prated
6.40 kW
SCOP
3.17
Tbiv
-17 °C
TOL
-17 °C
Pdh Tj = -7°C
3.98 kW
COP Tj = -7°C
2.82
Cdh Tj = -7 °C
1.000
Pdh Tj = +2°C
2.35 kW
COP Tj = +2°C
3.63
Cdh Tj = +2 °C
0.990
Pdh Tj = +7°C
2.30 kW
COP Tj = +7°C
4.92
Cdh Tj = +7 °C
0.980
Pdh Tj = 12°C
2.70 kW
COP Tj = 12°C
6.80
Cdh Tj = +12 °C
0.980
Pdh Tj = Tbiv
5.59 kW
COP Tj = Tbiv
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.94
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
WTOL
67 °C
Poff
8 W
PTO
8 W
PSB
8 W
PCK
8 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
6.40 kW
Annual energy consumption Qhe
4984 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.22
COP Tj = -15°C (if TOL<-20°C)
1.90
Cdh Tj = -15 °C
1.000
Average Climate
EN 12102-1
Medium temperature
Sound power level indoor
42 dB(A)
Sound power level outdoor
45 dB(A)
EN 14825
Medium temperature
ηs
141 %
Prated
6.10 kW
SCOP
3.66
Tbiv
-10 °C
TOL
-10 °C
Pdh Tj = -7°C
5.46 kW
COP Tj = -7°C
2.32
Cdh Tj = -7 °C
1.000
Pdh Tj = +2°C
3.30 kW
COP Tj = +2°C
3.71
Cdh Tj = +2 °C
0.990
Pdh Tj = +7°C
2.20 kW
COP Tj = +7°C
4.30
Cdh Tj = +7 °C
0.980
Pdh Tj = 12°C
2.53 kW
COP Tj = 12°C
5.82
Cdh Tj = +12 °C
0.980
Pdh Tj = Tbiv
6.07 kW
COP Tj = Tbiv
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.07 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
WTOL
67 °C
Poff
8 W
PTO
8 W
PSB
8 W
PCK
8 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.00 kW
Annual energy consumption Qhe
3441 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
100 %
COP
2.38
Heating up time
2:27 h:min
Standby power input
44.9 W
Reference hot water temperature
54.9 °C
Mixed water at 40°C