1,800 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5 kW
4 kW
El input
0.99 kW
1.63 kW
COP
5.05
2.45
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.5 kW
1.14 kW
Cooling capacity
5.1
6
EER
3.4
5.25
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.1 kW
6 kW
SEER
3.88
5.91
Pdc Tj = 35°C
5.1 kW
6 kW
EER Tj = 35°C
3.4
5.25
Cdc Tj = 35 °C
0.99
0.987
Pdc Tj = 30°C
3.76 kW
4.42 kW
EER Tj = 30°C
3.84
5.95
Cdc Tj = 30 °C
0.985
0.98
Pdc Tj = 25°C
2.42 kW
3.3 kW
EER Tj = 25°C
4.07
6.38
Cdc Tj = 25 °C
0.975
0.971
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.57
7
Cdc Tj = 20 °C
0.973
0.97
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
789 kWh
609 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
129 %
Prated
6 kW
6 kW
SCOP
4.67
3.3
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.31 kW
5.31 kW
COP Tj = -7°C
3.39
2.28
Cdh Tj = -7 °C
0.99
0.994
Pdh Tj = +2°C
4.8 kW
4.4 kW
COP Tj = +2°C
4.76
3.21
Cdh Tj = +2 °C
0.985
0.989
Pdh Tj = +7°C
4.9 kW
4.1 kW
COP Tj = +7°C
5.9
4.2
Cdh Tj = +7 °C
0.982
0.985
Pdh Tj = 12°C
3 kW
2.7 kW
COP Tj = 12°C
6.52
5.87
Cdh Tj = +12 °C
0.967
0.967
Pdh Tj = Tbiv
6 kW
6 kW
COP Tj = Tbiv
2.74
2
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6 kW
6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
2
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2655 kWh
3761 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
133 %
COP
3.22
Heating up time
2:31 h:min
Standby power input
47 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6 kW
4 kW
El input
1.19 kW
1.6 kW
COP
5.05
2.5
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.22 kW
1.63 kW
Cooling capacity
7.1
8
EER
3.2
4.9
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.1 kW
8 kW
SEER
4.12
5.74
Pdc Tj = 35°C
7.1 kW
8 kW
EER Tj = 35°C
3.2
4.9
Cdc Tj = 35 °C
0.993
0.991
Pdc Tj = 30°C
5.23 kW
5.92 kW
EER Tj = 30°C
3.85
5.7
Cdc Tj = 30 °C
0.989
0.986
Pdc Tj = 25°C
3.36 kW
3.79 kW
EER Tj = 25°C
4.55
6
Cdc Tj = 25 °C
0.98
0.976
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.69
6.75
Cdc Tj = 20 °C
0.972
0.971
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
1034 kWh
836 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
132 %
Prated
8 kW
8 kW
SCOP
4.68
3.37
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.08 kW
7.08 kW
COP Tj = -7°C
3.22
2.31
Cdh Tj = -7 °C
0.993
0.995
Pdh Tj = +2°C
4.4 kW
4.4 kW
COP Tj = +2°C
4.75
3.21
Cdh Tj = +2 °C
0.984
0.989
Pdh Tj = +7°C
5 kW
4.4 kW
COP Tj = +7°C
5.9
4.4
Cdh Tj = +7 °C
0.982
0.985
Pdh Tj = 12°C
3 kW
2.8 kW
COP Tj = 12°C
6.52
6.09
Cdh Tj = +12 °C
0.967
0.967
Pdh Tj = Tbiv
8 kW
8 kW
COP Tj = Tbiv
2.65
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8 kW
8 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.65
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.997
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3530 kWh
4904 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
133 %
COP
3.22
Heating up time
2:31 h:min
Standby power input
47 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6 kW
4 kW
El input
1.19 kW
1.6 kW
COP
5.05
2.5
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.22 kW
1.63 kW
Cooling capacity
7.1
8
EER
3.2
4.9
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.1 kW
8 kW
SEER
4.06
5.62
Pdc Tj = 35°C
7.1 kW
8 kW
EER Tj = 35°C
3.2
4.9
Cdc Tj = 35 °C
0.99
0.987
Pdc Tj = 30°C
5.23 kW
5.92 kW
EER Tj = 30°C
3.85
5.7
Cdc Tj = 30 °C
0.984
0.979
Pdc Tj = 25°C
3.36 kW
3.79 kW
EER Tj = 25°C
4.55
6
Cdc Tj = 25 °C
0.97
0.965
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.69
6.75
Cdc Tj = 20 °C
0.959
0.958
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Annual energy consumption Qce
1051 kWh
853 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
131 %
Prated
8 kW
8 kW
SCOP
4.63
3.34
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.08 kW
7.08 kW
COP Tj = -7°C
3.22
2.31
Cdh Tj = -7 °C
0.99
0.993
Pdh Tj = +2°C
4.4 kW
4.4 kW
COP Tj = +2°C
4.75
3.21
Cdh Tj = +2 °C
0.976
0.984
Pdh Tj = +7°C
5 kW
4.4 kW
COP Tj = +7°C
5.9
4.4
Cdh Tj = +7 °C
0.974
0.978
Pdh Tj = 12°C
3 kW
2.8 kW
COP Tj = 12°C
6.52
6.09
Cdh Tj = +12 °C
0.952
0.952
Pdh Tj = Tbiv
8 kW
8 kW
COP Tj = Tbiv
2.65
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8 kW
8 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.65
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3568 kWh
4941 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
133 %
COP
3.22
Heating up time
2:31 h:min
Standby power input
47 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8 kW
7 kW
El input
1.6 kW
2.59 kW
COP
5
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
3.05 kW
2.2 kW
Cooling capacity
9
10
EER
2.95
4.55
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9 kW
10 kW
SEER
3.97
5.73
Pdc Tj = 35°C
9 kW
10 kW
EER Tj = 35°C
2.95
4.55
Cdc Tj = 35 °C
0.995
0.993
Pdc Tj = 30°C
6.63 kW
7.37 kW
EER Tj = 30°C
3.82
5.66
Cdc Tj = 30 °C
0.991
0.988
Pdc Tj = 25°C
4.26 kW
4.74 kW
EER Tj = 25°C
4.43
6.05
Cdc Tj = 25 °C
0.984
0.981
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.23
6.55
Cdc Tj = 20 °C
0.975
0.972
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
1359 kWh
1047 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
136 %
Prated
10 kW
10 kW
SCOP
4.65
3.48
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.85 kW
8.85 kW
COP Tj = -7°C
3.1
2.19
Cdh Tj = -7 °C
0.995
0.996
Pdh Tj = +2°C
5.4 kW
5.4 kW
COP Tj = +2°C
4.62
3.38
Cdh Tj = +2 °C
0.987
0.991
Pdh Tj = +7°C
5.2 kW
4.8 kW
COP Tj = +7°C
6
4.62
Cdh Tj = +7 °C
0.983
0.986
Pdh Tj = 12°C
3.2 kW
2.9 kW
COP Tj = 12°C
6.96
6.3
Cdh Tj = +12 °C
0.967
0.967
Pdh Tj = Tbiv
10 kW
10 kW
COP Tj = Tbiv
2.49
1.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10 kW
10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.49
1.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
4444 kWh
5936 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
133 %
COP
3.22
Heating up time
2:31 h:min
Standby power input
47 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8 kW
7 kW
El input
1.6 kW
2.59 kW
COP
5
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
3.05 kW
2.2 kW
Cooling capacity
9
10
EER
2.95
4.55
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9 kW
10 kW
SEER
3.93
5.64
Pdc Tj = 35°C
9 kW
10 kW
EER Tj = 35°C
2.95
4.55
Cdc Tj = 35 °C
0.993
0.99
Pdc Tj = 30°C
6.63 kW
7.37 kW
EER Tj = 30°C
3.82
5.66
Cdc Tj = 30 °C
0.987
0.983
Pdc Tj = 25°C
4.26 kW
4.74 kW
EER Tj = 25°C
4.43
6.05
Cdc Tj = 25 °C
0.977
0.972
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.23
6.55
Cdc Tj = 20 °C
0.963
0.959
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Annual energy consumption Qce
1375 kWh
1064 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
135 %
Prated
10 kW
10 kW
SCOP
4.61
3.46
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.85 kW
8.85 kW
COP Tj = -7°C
3.1
2.19
Cdh Tj = -7 °C
0.992
0.995
Pdh Tj = +2°C
5.4 kW
5.4 kW
COP Tj = +2°C
4.62
3.38
Cdh Tj = +2 °C
0.981
0.986
Pdh Tj = +7°C
5.2 kW
4.8 kW
COP Tj = +7°C
6
4.62
Cdh Tj = +7 °C
0.975
0.979
Pdh Tj = 12°C
3.2 kW
2.9 kW
COP Tj = 12°C
6.96
6.3
Cdh Tj = +12 °C
0.952
0.952
Pdh Tj = Tbiv
10 kW
10 kW
COP Tj = Tbiv
2.49
1.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10 kW
10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.49
1.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
4480 kWh
5972 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
133 %
COP
3.22
Heating up time
2:31 h:min
Standby power input
47 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5 kW
4 kW
El input
0.99 kW
1.63 kW
COP
5.05
2.45
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.5 kW
1.14 kW
Cooling capacity
5.1
6
EER
3.4
5.25
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.1 kW
6 kW
SEER
3.88
5.91
Pdc Tj = 35°C
5.1 kW
6 kW
EER Tj = 35°C
3.4
5.25
Cdc Tj = 35 °C
0.99
0.987
Pdc Tj = 30°C
3.76 kW
4.42 kW
EER Tj = 30°C
3.84
5.95
Cdc Tj = 30 °C
0.985
0.98
Pdc Tj = 25°C
2.42 kW
3.3 kW
EER Tj = 25°C
4.07
6.38
Cdc Tj = 25 °C
0.975
0.971
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.57
7
Cdc Tj = 20 °C
0.973
0.97
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
789 kWh
609 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
131 %
Prated
6 kW
6 kW
SCOP
4.77
3.34
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.31 kW
5.31 kW
COP Tj = -7°C
3.39
2.28
Cdh Tj = -7 °C
0.99
0.994
Pdh Tj = +2°C
4.8 kW
4.4 kW
COP Tj = +2°C
4.76
3.21
Cdh Tj = +2 °C
0.985
0.989
Pdh Tj = +7°C
4.9 kW
4.1 kW
COP Tj = +7°C
5.9
4.2
Cdh Tj = +7 °C
0.982
0.985
Pdh Tj = 12°C
3 kW
2.7 kW
COP Tj = 12°C
6.52
5.87
Cdh Tj = +12 °C
0.967
0.967
Pdh Tj = Tbiv
6 kW
6 kW
COP Tj = Tbiv
2.74
2
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6 kW
6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
2
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2600 kWh
3706 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
133 %
COP
3.22
Heating up time
2:31 h:min
Standby power input
47 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6 kW
4 kW
El input
1.19 kW
1.6 kW
COP
5.05
2.5
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.22 kW
1.63 kW
Cooling capacity
7.1
8
EER
3.2
4.9
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.1 kW
8 kW
SEER
4.12
5.74
Pdc Tj = 35°C
7.1 kW
8 kW
EER Tj = 35°C
3.2
4.9
Cdc Tj = 35 °C
0.993
0.991
Pdc Tj = 30°C
5.23 kW
5.92 kW
EER Tj = 30°C
3.85
5.7
Cdc Tj = 30 °C
0.989
0.986
Pdc Tj = 25°C
3.36 kW
3.79 kW
EER Tj = 25°C
4.55
6
Cdc Tj = 25 °C
0.98
0.976
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.69
6.75
Cdc Tj = 20 °C
0.972
0.971
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
1034 kWh
836 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
133 %
Prated
8 kW
8 kW
SCOP
4.76
3.41
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.08 kW
7.08 kW
COP Tj = -7°C
3.22
2.31
Cdh Tj = -7 °C
0.993
0.995
Pdh Tj = +2°C
4.4 kW
4.4 kW
COP Tj = +2°C
4.75
3.21
Cdh Tj = +2 °C
0.984
0.989
Pdh Tj = +7°C
5 kW
4.4 kW
COP Tj = +7°C
5.9
4.4
Cdh Tj = +7 °C
0.982
0.985
Pdh Tj = 12°C
3 kW
2.8 kW
COP Tj = 12°C
6.52
6.09
Cdh Tj = +12 °C
0.967
0.967
Pdh Tj = Tbiv
8 kW
8 kW
COP Tj = Tbiv
2.65
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8 kW
8 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.65
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.997
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3475 kWh
4849 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
133 %
COP
3.22
Heating up time
2:31 h:min
Standby power input
47 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6 kW
4 kW
El input
1.19 kW
1.6 kW
COP
5.05
2.5
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.22 kW
1.63 kW
Cooling capacity
7.1
8
EER
3.2
4.9
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.1 kW
8 kW
SEER
4.06
5.62
Pdc Tj = 35°C
7.1 kW
8 kW
EER Tj = 35°C
3.2
4.9
Cdc Tj = 35 °C
0.99
0.987
Pdc Tj = 30°C
5.23 kW
5.92 kW
EER Tj = 30°C
3.85
5.7
Cdc Tj = 30 °C
0.984
0.979
Pdc Tj = 25°C
3.36 kW
3.79 kW
EER Tj = 25°C
4.55
6
Cdc Tj = 25 °C
0.97
0.965
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.69
6.75
Cdc Tj = 20 °C
0.959
0.958
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Annual energy consumption Qce
1051 kWh
853 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
133 %
Prated
8 kW
8 kW
SCOP
4.74
3.4
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.08 kW
7.08 kW
COP Tj = -7°C
3.22
2.31
Cdh Tj = -7 °C
0.99
0.993
Pdh Tj = +2°C
4.4 kW
4.4 kW
COP Tj = +2°C
4.75
3.21
Cdh Tj = +2 °C
0.976
0.984
Pdh Tj = +7°C
5 kW
4.4 kW
COP Tj = +7°C
5.9
4.4
Cdh Tj = +7 °C
0.974
0.978
Pdh Tj = 12°C
3 kW
2.8 kW
COP Tj = 12°C
6.52
6.09
Cdh Tj = +12 °C
0.952
0.952
Pdh Tj = Tbiv
8 kW
8 kW
COP Tj = Tbiv
2.65
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8 kW
8 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.65
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
3487 kWh
4860 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
133 %
COP
3.22
Heating up time
2:31 h:min
Standby power input
47 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8 kW
7 kW
El input
1.6 kW
2.59 kW
COP
5
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
3.05 kW
2.2 kW
Cooling capacity
9
10
EER
2.95
4.55
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9 kW
10 kW
SEER
3.97
5.73
Pdc Tj = 35°C
9 kW
10 kW
EER Tj = 35°C
2.95
4.55
Cdc Tj = 35 °C
0.995
0.993
Pdc Tj = 30°C
6.63 kW
7.37 kW
EER Tj = 30°C
3.82
5.66
Cdc Tj = 30 °C
0.991
0.988
Pdc Tj = 25°C
4.26 kW
4.74 kW
EER Tj = 25°C
4.43
6.05
Cdc Tj = 25 °C
0.984
0.981
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.23
6.55
Cdc Tj = 20 °C
0.975
0.972
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
1359 kWh
1047 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
138 %
Prated
10 kW
10 kW
SCOP
4.71
3.51
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.85 kW
8.85 kW
COP Tj = -7°C
3.1
2.19
Cdh Tj = -7 °C
0.995
0.996
Pdh Tj = +2°C
5.4 kW
5.4 kW
COP Tj = +2°C
4.62
3.38
Cdh Tj = +2 °C
0.987
0.991
Pdh Tj = +7°C
5.2 kW
4.8 kW
COP Tj = +7°C
6
4.62
Cdh Tj = +7 °C
0.983
0.986
Pdh Tj = 12°C
3.2 kW
2.9 kW
COP Tj = 12°C
6.96
6.3
Cdh Tj = +12 °C
0.967
0.967
Pdh Tj = Tbiv
10 kW
10 kW
COP Tj = Tbiv
2.49
1.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10 kW
10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.49
1.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
4389 kWh
5881 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
133 %
COP
3.22
Heating up time
2:31 h:min
Standby power input
47 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8 kW
7 kW
El input
1.6 kW
2.59 kW
COP
5
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
3.05 kW
2.2 kW
Cooling capacity
9
10
EER
2.95
4.55
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9 kW
10 kW
SEER
3.93
5.64
Pdc Tj = 35°C
9 kW
10 kW
EER Tj = 35°C
2.95
4.55
Cdc Tj = 35 °C
0.993
0.99
Pdc Tj = 30°C
6.63 kW
7.37 kW
EER Tj = 30°C
3.82
5.66
Cdc Tj = 30 °C
0.987
0.983
Pdc Tj = 25°C
4.26 kW
4.74 kW
EER Tj = 25°C
4.43
6.05
Cdc Tj = 25 °C
0.977
0.972
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.23
6.55
Cdc Tj = 20 °C
0.963
0.959
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Annual energy consumption Qce
1375 kWh
1064 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
137 %
Prated
10 kW
10 kW
SCOP
4.7
3.51
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.85 kW
8.85 kW
COP Tj = -7°C
3.1
2.19
Cdh Tj = -7 °C
0.992
0.995
Pdh Tj = +2°C
5.4 kW
5.4 kW
COP Tj = +2°C
4.62
3.38
Cdh Tj = +2 °C
0.981
0.986
Pdh Tj = +7°C
5.2 kW
4.8 kW
COP Tj = +7°C
6
4.62
Cdh Tj = +7 °C
0.975
0.979
Pdh Tj = 12°C
3.2 kW
2.9 kW
COP Tj = 12°C
6.96
6.3
Cdh Tj = +12 °C
0.952
0.952
Pdh Tj = Tbiv
10 kW
10 kW
COP Tj = Tbiv
2.49
1.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10 kW
10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.49
1.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
4399 kWh
5891 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
133 %
COP
3.22
Heating up time
2:31 h:min
Standby power input
47 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l