0,800 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3 kW
3.6 kW
El input
0.59 kW
1.27 kW
COP
5.11
2.83
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
191 %
130 %
Prated
4 kW
3.6 kW
SCOP
4.84
3.34
Tbiv
-10 °C
-10 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
3.6 kW
3.2 kW
COP Tj = -7°C
3.4
2.27
Cdh Tj = -7 °C
0.991
0.993
Pdh Tj = +2°C
2.2 kW
2 kW
COP Tj = +2°C
4.63
3.13
Cdh Tj = +2 °C
0.979
0.984
Pdh Tj = +7°C
2.4 kW
2.2 kW
COP Tj = +7°C
6.51
4.53
Cdh Tj = +7 °C
0.973
0.979
Pdh Tj = 12°C
2.4 kW
2 kW
COP Tj = 12°C
9.28
7.17
Cdh Tj = +12 °C
0.961
0.964
Pdh Tj = Tbiv
4 kW
3.6 kW
COP Tj = Tbiv
2.79
1.74
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4 kW
3.6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.79
1.74
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1706 kWh
2230 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
147 %
COP
3.28
Heating up time
2:34 h:min
Standby power input
30 W
Reference hot water temperature
53 °C
Mixed water at 40°C
239 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3 kW
3.6 kW
El input
0.59 kW
1.27 kW
COP
5.11
2.83
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
133 %
Prated
4 kW
3.6 kW
SCOP
4.95
3.39
Tbiv
-10 °C
-10 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
3.6 kW
3.2 kW
COP Tj = -7°C
3.4
2.27
Cdh Tj = -7 °C
0.991
0.993
Pdh Tj = +2°C
2.2 kW
2 kW
COP Tj = +2°C
4.63
3.13
Cdh Tj = +2 °C
0.979
0.984
Pdh Tj = +7°C
2.4 kW
2.2 kW
COP Tj = +7°C
6.51
4.53
Cdh Tj = +7 °C
0.973
0.979
Pdh Tj = 12°C
2.4 kW
2 kW
COP Tj = 12°C
9.28
7.17
Cdh Tj = +12 °C
0.961
0.964
Pdh Tj = Tbiv
4 kW
3.6 kW
COP Tj = Tbiv
2.79
1.74
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4 kW
3.6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.79
1.74
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1670 kWh
2193 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
147 %
COP
3.28
Heating up time
2:34 h:min
Standby power input
30 W
Reference hot water temperature
53 °C
Mixed water at 40°C
239 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3 kW
3.6 kW
El input
0.59 kW
1.27 kW
COP
5.11
2.83
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
133 %
Prated
4 kW
3.6 kW
SCOP
4.95
3.39
Tbiv
-10 °C
-10 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
3.6 kW
3.2 kW
COP Tj = -7°C
3.4
2.27
Cdh Tj = -7 °C
0.991
0.993
Pdh Tj = +2°C
2.2 kW
2 kW
COP Tj = +2°C
4.63
3.13
Cdh Tj = +2 °C
0.979
0.984
Pdh Tj = +7°C
2.4 kW
2.2 kW
COP Tj = +7°C
6.51
4.53
Cdh Tj = +7 °C
0.973
0.979
Pdh Tj = 12°C
2.4 kW
2 kW
COP Tj = 12°C
9.28
7.17
Cdh Tj = +12 °C
0.961
0.964
Pdh Tj = Tbiv
4 kW
3.6 kW
COP Tj = Tbiv
2.79
1.74
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4 kW
3.6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.79
1.74
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1670 kWh
2193 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
147 %
COP
3.28
Heating up time
2:34 h:min
Standby power input
30 W
Reference hot water temperature
53 °C
Mixed water at 40°C
239 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3 kW
3.6 kW
El input
0.59 kW
1.27 kW
COP
5.11
2.83
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
124 %
Prated
4 kW
3.6 kW
SCOP
4.59
3.17
Tbiv
-10 °C
-10 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
3.6 kW
3.2 kW
COP Tj = -7°C
3.23
2.18
Cdh Tj = -7 °C
0.991
0.993
Pdh Tj = +2°C
2.2 kW
2 kW
COP Tj = +2°C
4.19
2.87
Cdh Tj = +2 °C
0.981
0.986
Pdh Tj = +7°C
2.4 kW
2.2 kW
COP Tj = +7°C
6.62
4.53
Cdh Tj = +7 °C
0.972
0.979
Pdh Tj = 12°C
2.4 kW
2 kW
COP Tj = 12°C
9.51
7.17
Cdh Tj = +12 °C
0.96
0.964
Pdh Tj = Tbiv
4 kW
3.6 kW
COP Tj = Tbiv
2.69
1.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4 kW
3.6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1802 kWh
2347 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
147 %
COP
3.28
Heating up time
2:34 h:min
Standby power input
30 W
Reference hot water temperature
53 °C
Mixed water at 40°C
239 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3 kW
3.6 kW
El input
0.59 kW
1.27 kW
COP
5.11
2.83
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
126 %
Prated
4 kW
3.6 kW
SCOP
4.68
3.22
Tbiv
-10 °C
-10 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
3.6 kW
3.2 kW
COP Tj = -7°C
3.23
2.18
Cdh Tj = -7 °C
0.991
0.993
Pdh Tj = +2°C
2.2 kW
2 kW
COP Tj = +2°C
4.19
2.87
Cdh Tj = +2 °C
0.981
0.986
Pdh Tj = +7°C
2.4 kW
2.2 kW
COP Tj = +7°C
6.62
4.53
Cdh Tj = +7 °C
0.972
0.979
Pdh Tj = 12°C
2.4 kW
2 kW
COP Tj = 12°C
9.51
7.17
Cdh Tj = +12 °C
0.96
0.964
Pdh Tj = Tbiv
4 kW
3.6 kW
COP Tj = Tbiv
2.69
1.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4 kW
3.6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1766 kWh
2311 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
147 %
COP
3.28
Heating up time
2:34 h:min
Standby power input
30 W
Reference hot water temperature
53 °C
Mixed water at 40°C
239 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3 kW
3.6 kW
El input
0.59 kW
1.27 kW
COP
5.11
2.83
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
126 %
Prated
4 kW
3.6 kW
SCOP
4.68
3.22
Tbiv
-10 °C
-10 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
3.6 kW
3.2 kW
COP Tj = -7°C
3.23
2.18
Cdh Tj = -7 °C
0.991
0.993
Pdh Tj = +2°C
2.2 kW
2 kW
COP Tj = +2°C
4.19
2.87
Cdh Tj = +2 °C
0.981
0.986
Pdh Tj = +7°C
2.4 kW
2.2 kW
COP Tj = +7°C
6.62
4.53
Cdh Tj = +7 °C
0.972
0.979
Pdh Tj = 12°C
2.4 kW
2 kW
COP Tj = 12°C
9.51
7.17
Cdh Tj = +12 °C
0.96
0.964
Pdh Tj = Tbiv
4 kW
3.6 kW
COP Tj = Tbiv
2.69
1.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4 kW
3.6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1766 kWh
2311 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
147 %
COP
3.28
Heating up time
2:34 h:min
Standby power input
30 W
Reference hot water temperature
53 °C
Mixed water at 40°C
239 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3 kW
3.6 kW
El input
0.59 kW
1.29 kW
COP
5.11
2.79
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
196 %
133 %
Prated
4.7 kW
4.5 kW
SCOP
4.97
3.4
Tbiv
-10 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
4.2 kW
4 kW
COP Tj = -7°C
3.43
2.23
Cdh Tj = -7 °C
0.992
0.994
Pdh Tj = +2°C
2.6 kW
2.5 kW
COP Tj = +2°C
4.73
3.21
Cdh Tj = +2 °C
0.982
0.987
Pdh Tj = +7°C
2.4 kW
2.2 kW
COP Tj = +7°C
6.64
4.6
Cdh Tj = +7 °C
0.972
0.979
Pdh Tj = 12°C
2.4 kW
2.8 kW
COP Tj = 12°C
9.54
6.94
Cdh Tj = +12 °C
0.96
0.975
Pdh Tj = Tbiv
4.7 kW
4 kW
COP Tj = Tbiv
2.91
2.23
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.7 kW
4.3 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0.2 kW
Annual energy consumption Qhe
1954 kWh
2735 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
147 %
COP
3.28
Heating up time
2:34 h:min
Standby power input
30 W
Reference hot water temperature
53 °C
Mixed water at 40°C
239 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3 kW
3.6 kW
El input
0.59 kW
1.29 kW
COP
5.11
2.79
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
135 %
Prated
4.7 kW
4.5 kW
SCOP
5.06
3.45
Tbiv
-10 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
4.2 kW
4 kW
COP Tj = -7°C
3.43
2.23
Cdh Tj = -7 °C
0.992
0.994
Pdh Tj = +2°C
2.6 kW
2.5 kW
COP Tj = +2°C
4.73
3.21
Cdh Tj = +2 °C
0.982
0.987
Pdh Tj = +7°C
2.4 kW
2.2 kW
COP Tj = +7°C
6.64
4.6
Cdh Tj = +7 °C
0.972
0.979
Pdh Tj = 12°C
2.4 kW
2.8 kW
COP Tj = 12°C
9.54
6.94
Cdh Tj = +12 °C
0.96
0.975
Pdh Tj = Tbiv
4.7 kW
4 kW
COP Tj = Tbiv
2.91
2.23
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.7 kW
4.3 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0.2 kW
Annual energy consumption Qhe
1918 kWh
2699 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
147 %
COP
3.28
Heating up time
2:34 h:min
Standby power input
30 W
Reference hot water temperature
53 °C
Mixed water at 40°C
239 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3 kW
3.6 kW
El input
0.59 kW
1.29 kW
COP
5.11
2.79
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
135 %
Prated
4.7 kW
4.5 kW
SCOP
5.06
3.45
Tbiv
-10 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
4.2 kW
4 kW
COP Tj = -7°C
3.43
2.23
Cdh Tj = -7 °C
0.992
0.994
Pdh Tj = +2°C
2.6 kW
2.5 kW
COP Tj = +2°C
4.73
3.21
Cdh Tj = +2 °C
0.982
0.987
Pdh Tj = +7°C
2.4 kW
2.2 kW
COP Tj = +7°C
6.64
4.6
Cdh Tj = +7 °C
0.972
0.979
Pdh Tj = 12°C
2.4 kW
2.8 kW
COP Tj = 12°C
9.54
6.94
Cdh Tj = +12 °C
0.96
0.975
Pdh Tj = Tbiv
4.7 kW
4 kW
COP Tj = Tbiv
2.91
2.23
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.7 kW
4.3 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0.2 kW
Annual energy consumption Qhe
1918 kWh
2699 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
147 %
COP
3.28
Heating up time
2:34 h:min
Standby power input
30 W
Reference hot water temperature
53 °C
Mixed water at 40°C
239 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3 kW
3.6 kW
El input
0.59 kW
1.27 kW
COP
5.11
2.83
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
0.99 kW
0.64 kW
Cooling capacity
3.5
3.5
EER
3.52
5.51
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.5 kW
3.5 kW
SEER
4.69
5.89
Pdc Tj = 35°C
3.5 kW
3.5 kW
EER Tj = 35°C
3.52
5.51
Cdc Tj = 35 °C
0.99
0.984
Pdc Tj = 30°C
2.58 kW
2.58 kW
EER Tj = 30°C
4.22
6.56
Cdc Tj = 30 °C
0.984
0.975
Pdc Tj = 25°C
1.66 kW
1.89 kW
EER Tj = 25°C
4.73
4.86
Cdc Tj = 25 °C
0.972
0.974
Pdc Tj = 20°C
1.53 kW
1.93 kW
EER Tj = 20°C
7.35
10.05
Cdc Tj = 20 °C
0.952
0.948
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Annual energy consumption Qce
447 kWh
357 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
191 %
130 %
Prated
4 kW
3.6 kW
SCOP
4.84
3.34
Tbiv
-10 °C
-10 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
3.6 kW
3.2 kW
COP Tj = -7°C
3.4
2.27
Cdh Tj = -7 °C
0.991
0.993
Pdh Tj = +2°C
2.2 kW
2 kW
COP Tj = +2°C
4.63
3.13
Cdh Tj = +2 °C
0.979
0.984
Pdh Tj = +7°C
2.4 kW
2.2 kW
COP Tj = +7°C
6.51
4.53
Cdh Tj = +7 °C
0.973
0.979
Pdh Tj = 12°C
2.4 kW
2 kW
COP Tj = 12°C
9.28
7.17
Cdh Tj = +12 °C
0.961
0.964
Pdh Tj = Tbiv
4 kW
3.6 kW
COP Tj = Tbiv
2.79
1.74
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4 kW
3.6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.79
1.74
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1706 kWh
2230 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
136 %
COP
3.32
Heating up time
2:36 h:min
Standby power input
22.4 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3 kW
3.6 kW
El input
0.59 kW
1.27 kW
COP
5.11
2.83
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
0.99 kW
0.64 kW
Cooling capacity
3.5
3.5
EER
3.52
5.51
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.5 kW
3.5 kW
SEER
4.69
5.89
Pdc Tj = 35°C
3.5 kW
3.5 kW
EER Tj = 35°C
3.52
5.51
Cdc Tj = 35 °C
0.99
0.984
Pdc Tj = 30°C
2.58 kW
2.58 kW
EER Tj = 30°C
4.22
6.56
Cdc Tj = 30 °C
0.984
0.975
Pdc Tj = 25°C
1.66 kW
1.89 kW
EER Tj = 25°C
4.73
4.86
Cdc Tj = 25 °C
0.972
0.974
Pdc Tj = 20°C
1.53 kW
1.93 kW
EER Tj = 20°C
7.35
10.05
Cdc Tj = 20 °C
0.952
0.948
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Annual energy consumption Qce
447 kWh
357 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
133 %
Prated
4 kW
3.6 kW
SCOP
4.95
3.39
Tbiv
-10 °C
-10 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
3.6 kW
3.2 kW
COP Tj = -7°C
3.4
2.27
Cdh Tj = -7 °C
0.991
0.993
Pdh Tj = +2°C
2.2 kW
2 kW
COP Tj = +2°C
4.63
3.13
Cdh Tj = +2 °C
0.979
0.984
Pdh Tj = +7°C
2.4 kW
2.2 kW
COP Tj = +7°C
6.51
4.53
Cdh Tj = +7 °C
0.973
0.979
Pdh Tj = 12°C
2.4 kW
2 kW
COP Tj = 12°C
9.28
7.17
Cdh Tj = +12 °C
0.961
0.964
Pdh Tj = Tbiv
4 kW
3.6 kW
COP Tj = Tbiv
2.79
1.74
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4 kW
3.6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.79
1.74
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1670 kWh
2193 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
136 %
COP
3.32
Heating up time
2:36 h:min
Standby power input
22.4 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3 kW
3.6 kW
El input
0.59 kW
1.27 kW
COP
5.11
2.83
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
0.99 kW
0.64 kW
Cooling capacity
3.5
3.5
EER
3.52
5.51
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.5 kW
3.5 kW
SEER
4.69
5.89
Pdc Tj = 35°C
3.5 kW
3.5 kW
EER Tj = 35°C
3.52
5.51
Cdc Tj = 35 °C
0.99
0.984
Pdc Tj = 30°C
2.58 kW
2.58 kW
EER Tj = 30°C
4.22
6.56
Cdc Tj = 30 °C
0.984
0.975
Pdc Tj = 25°C
1.66 kW
1.89 kW
EER Tj = 25°C
4.73
4.86
Cdc Tj = 25 °C
0.972
0.974
Pdc Tj = 20°C
1.53 kW
1.93 kW
EER Tj = 20°C
7.35
10.05
Cdc Tj = 20 °C
0.952
0.948
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Annual energy consumption Qce
447 kWh
357 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
133 %
Prated
4 kW
3.6 kW
SCOP
4.95
3.39
Tbiv
-10 °C
-10 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
3.6 kW
3.2 kW
COP Tj = -7°C
3.4
2.27
Cdh Tj = -7 °C
0.991
0.993
Pdh Tj = +2°C
2.2 kW
2 kW
COP Tj = +2°C
4.63
3.13
Cdh Tj = +2 °C
0.979
0.984
Pdh Tj = +7°C
2.4 kW
2.2 kW
COP Tj = +7°C
6.51
4.53
Cdh Tj = +7 °C
0.973
0.979
Pdh Tj = 12°C
2.4 kW
2 kW
COP Tj = 12°C
9.28
7.17
Cdh Tj = +12 °C
0.961
0.964
Pdh Tj = Tbiv
4 kW
3.6 kW
COP Tj = Tbiv
2.79
1.74
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4 kW
3.6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.79
1.74
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1670 kWh
2193 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
136 %
COP
3.32
Heating up time
2:36 h:min
Standby power input
22.4 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3 kW
3.6 kW
El input
0.59 kW
1.27 kW
COP
5.11
2.83
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
0.99 kW
0.64 kW
Cooling capacity
3.5
3.5
EER
3.52
5.51
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.5 kW
3.5 kW
SEER
4.69
5.89
Pdc Tj = 35°C
3.5 kW
3.5 kW
EER Tj = 35°C
3.52
5.51
Cdc Tj = 35 °C
0.99
0.984
Pdc Tj = 30°C
2.58 kW
2.58 kW
EER Tj = 30°C
4.22
6.56
Cdc Tj = 30 °C
0.984
0.975
Pdc Tj = 25°C
1.66 kW
1.89 kW
EER Tj = 25°C
4.73
4.86
Cdc Tj = 25 °C
0.972
0.974
Pdc Tj = 20°C
1.53 kW
1.93 kW
EER Tj = 20°C
7.35
10.05
Cdc Tj = 20 °C
0.952
0.948
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Annual energy consumption Qce
447 kWh
357 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
126 %
Prated
4 kW
3.6 kW
SCOP
4.68
3.22
Tbiv
-10 °C
-10 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
3.6 kW
3.2 kW
COP Tj = -7°C
3.23
2.18
Cdh Tj = -7 °C
0.991
0.993
Pdh Tj = +2°C
2.2 kW
2 kW
COP Tj = +2°C
4.19
2.87
Cdh Tj = +2 °C
0.981
0.986
Pdh Tj = +7°C
2.4 kW
2.2 kW
COP Tj = +7°C
6.62
4.53
Cdh Tj = +7 °C
0.972
0.979
Pdh Tj = 12°C
2.4 kW
2 kW
COP Tj = 12°C
9.51
7.17
Cdh Tj = +12 °C
0.96
0.964
Pdh Tj = Tbiv
4 kW
3.6 kW
COP Tj = Tbiv
2.69
1.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4 kW
3.6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1766 kWh
2311 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
136 %
COP
3.32
Heating up time
2:36 h:min
Standby power input
22.4 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3 kW
3.6 kW
El input
0.59 kW
1.27 kW
COP
5.11
2.83
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
0.99 kW
0.64 kW
Cooling capacity
3.5
3.5
EER
3.52
5.51
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.5 kW
3.5 kW
SEER
4.69
5.89
Pdc Tj = 35°C
3.5 kW
3.5 kW
EER Tj = 35°C
3.52
5.51
Cdc Tj = 35 °C
0.99
0.984
Pdc Tj = 30°C
2.58 kW
2.58 kW
EER Tj = 30°C
4.22
6.56
Cdc Tj = 30 °C
0.984
0.975
Pdc Tj = 25°C
1.66 kW
1.89 kW
EER Tj = 25°C
4.73
4.86
Cdc Tj = 25 °C
0.972
0.974
Pdc Tj = 20°C
1.53 kW
1.93 kW
EER Tj = 20°C
7.35
10.05
Cdc Tj = 20 °C
0.952
0.948
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Annual energy consumption Qce
447 kWh
357 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
126 %
Prated
4 kW
3.6 kW
SCOP
4.68
3.22
Tbiv
-10 °C
-10 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
3.6 kW
3.2 kW
COP Tj = -7°C
3.23
2.18
Cdh Tj = -7 °C
0.991
0.993
Pdh Tj = +2°C
2.2 kW
2 kW
COP Tj = +2°C
4.19
2.87
Cdh Tj = +2 °C
0.981
0.986
Pdh Tj = +7°C
2.4 kW
2.2 kW
COP Tj = +7°C
6.62
4.53
Cdh Tj = +7 °C
0.972
0.979
Pdh Tj = 12°C
2.4 kW
2 kW
COP Tj = 12°C
9.51
7.17
Cdh Tj = +12 °C
0.96
0.964
Pdh Tj = Tbiv
4 kW
3.6 kW
COP Tj = Tbiv
2.69
1.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4 kW
3.6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1766 kWh
2311 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
136 %
COP
3.32
Heating up time
2:36 h:min
Standby power input
22.4 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3 kW
3.6 kW
El input
0.59 kW
1.29 kW
COP
5.11
2.79
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.36 kW
1.19 kW
Cooling capacity
4.5
5.6
EER
3.31
4.71
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
4.5 kW
5.6 kW
SEER
4.66
5.72
Pdc Tj = 35°C
4.5 kW
5.6 kW
EER Tj = 35°C
3.31
4.71
Cdc Tj = 35 °C
0.993
0.992
Pdc Tj = 30°C
3.32 kW
4.13 kW
EER Tj = 30°C
4.11
6.31
Cdc Tj = 30 °C
0.988
0.985
Pdc Tj = 25°C
2.13 kW
2.69 kW
EER Tj = 25°C
4.9
4.67
Cdc Tj = 25 °C
0.977
0.983
Pdc Tj = 20°C
1.54 kW
1.96 kW
EER Tj = 20°C
6.58
9
Cdc Tj = 20 °C
0.957
0.954
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Annual energy consumption Qce
580 kWh
587 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
196 %
133 %
Prated
4.7 kW
4.5 kW
SCOP
4.97
3.4
Tbiv
-10 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
4.2 kW
4 kW
COP Tj = -7°C
3.43
2.23
Cdh Tj = -7 °C
0.992
0.994
Pdh Tj = +2°C
2.6 kW
2.5 kW
COP Tj = +2°C
4.73
3.21
Cdh Tj = +2 °C
0.982
0.987
Pdh Tj = +7°C
2.4 kW
2.2 kW
COP Tj = +7°C
6.64
4.6
Cdh Tj = +7 °C
0.972
0.979
Pdh Tj = 12°C
2.4 kW
2.8 kW
COP Tj = 12°C
9.54
6.94
Cdh Tj = +12 °C
0.96
0.975
Pdh Tj = Tbiv
4.7 kW
4 kW
COP Tj = Tbiv
2.91
2.23
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.7 kW
4.3 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0.2 kW
Annual energy consumption Qhe
1954 kWh
2735 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
136 %
COP
3.32
Heating up time
2:36 h:min
Standby power input
22.4 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3 kW
3.6 kW
El input
0.59 kW
1.29 kW
COP
5.11
2.79
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.36 kW
1.19 kW
Cooling capacity
4.5
5.6
EER
3.31
4.71
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
4.5 kW
5.6 kW
SEER
4.66
5.72
Pdc Tj = 35°C
4.5 kW
5.6 kW
EER Tj = 35°C
3.31
4.71
Cdc Tj = 35 °C
0.993
0.992
Pdc Tj = 30°C
3.32 kW
4.13 kW
EER Tj = 30°C
4.11
6.31
Cdc Tj = 30 °C
0.988
0.985
Pdc Tj = 25°C
2.13 kW
2.69 kW
EER Tj = 25°C
4.9
4.67
Cdc Tj = 25 °C
0.977
0.983
Pdc Tj = 20°C
1.54 kW
1.96 kW
EER Tj = 20°C
6.58
9
Cdc Tj = 20 °C
0.957
0.954
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Annual energy consumption Qce
580 kWh
587 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
135 %
Prated
4.7 kW
4.5 kW
SCOP
5.06
3.45
Tbiv
-10 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
4.2 kW
4 kW
COP Tj = -7°C
3.43
2.23
Cdh Tj = -7 °C
0.992
0.994
Pdh Tj = +2°C
2.6 kW
2.5 kW
COP Tj = +2°C
4.73
3.21
Cdh Tj = +2 °C
0.982
0.987
Pdh Tj = +7°C
2.4 kW
2.2 kW
COP Tj = +7°C
6.64
4.6
Cdh Tj = +7 °C
0.972
0.979
Pdh Tj = 12°C
2.4 kW
2.8 kW
COP Tj = 12°C
9.54
6.94
Cdh Tj = +12 °C
0.96
0.975
Pdh Tj = Tbiv
4.7 kW
4 kW
COP Tj = Tbiv
2.91
2.23
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.7 kW
4.3 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0.2 kW
Annual energy consumption Qhe
1918 kWh
2699 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
136 %
COP
3.32
Heating up time
2:36 h:min
Standby power input
22.4 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3 kW
3.6 kW
El input
0.59 kW
1.29 kW
COP
5.11
2.79
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.36 kW
1.19 kW
Cooling capacity
4.5
5.6
EER
3.31
4.71
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
4.5 kW
5.6 kW
SEER
4.66
5.72
Pdc Tj = 35°C
4.5 kW
5.6 kW
EER Tj = 35°C
3.31
4.71
Cdc Tj = 35 °C
0.993
0.992
Pdc Tj = 30°C
3.32 kW
4.13 kW
EER Tj = 30°C
4.11
6.31
Cdc Tj = 30 °C
0.988
0.985
Pdc Tj = 25°C
2.13 kW
2.69 kW
EER Tj = 25°C
4.9
4.67
Cdc Tj = 25 °C
0.977
0.983
Pdc Tj = 20°C
1.54 kW
1.96 kW
EER Tj = 20°C
6.58
9
Cdc Tj = 20 °C
0.957
0.954
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Annual energy consumption Qce
580 kWh
587 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
135 %
Prated
4.7 kW
4.5 kW
SCOP
5.06
3.45
Tbiv
-10 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
4.2 kW
4 kW
COP Tj = -7°C
3.43
2.23
Cdh Tj = -7 °C
0.992
0.994
Pdh Tj = +2°C
2.6 kW
2.5 kW
COP Tj = +2°C
4.73
3.21
Cdh Tj = +2 °C
0.982
0.987
Pdh Tj = +7°C
2.4 kW
2.2 kW
COP Tj = +7°C
6.64
4.6
Cdh Tj = +7 °C
0.972
0.979
Pdh Tj = 12°C
2.4 kW
2.8 kW
COP Tj = 12°C
9.54
6.94
Cdh Tj = +12 °C
0.96
0.975
Pdh Tj = Tbiv
4.7 kW
4 kW
COP Tj = Tbiv
2.91
2.23
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.7 kW
4.3 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0.2 kW
Annual energy consumption Qhe
1918 kWh
2699 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
136 %
COP
3.32
Heating up time
2:36 h:min
Standby power input
22.4 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l