4,700 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.84 kW
7.36 kW
El input
1.54 kW
2.33 kW
COP
5.09
3.16
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
141 %
Prated
15.00 kW
15.00 kW
SCOP
4.63
3.59
Tbiv
-5 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.80 kW
13.26 kW
COP Tj = -7°C
2.98
2.48
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
8.30 kW
8.40 kW
COP Tj = +2°C
4.72
3.51
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
8.00 kW
7.80 kW
COP Tj = +7°C
6.16
4.61
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
9.10 kW
9.00 kW
COP Tj = 12°C
8.11
6.66
Cdh Tj = +12 °C
1.000
1.000
Pdh Tj = Tbiv
11.80 kW
12.50 kW
COP Tj = Tbiv
3.16
2.59
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.60 kW
13.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.87
2.28
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
65 °C
65 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
38 W
38 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.40 kW
1.60 kW
Annual energy consumption Qhe
6689 kWh
8620 kWh
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
219 %
163 %
Prated
8.00 kW
8.00 kW
SCOP
5.54
4.14
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
8.30 kW
8.40 kW
COP Tj = +2°C
4.14
2.74
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
7.90 kW
7.50 kW
COP Tj = +7°C
5.47
3.64
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
9.10 kW
9.00 kW
COP Tj = 12°C
7.72
6.11
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
8.30 kW
8.40 kW
COP Tj = Tbiv
4.14
2.74
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
16.90 kW
18.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.61
2.31
WTOL
65 °C
65 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
38 W
38 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1930 kWh
2581 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
159 %
130 %
Prated
21.00 kW
22.00 kW
SCOP
4.05
3.33
Tbiv
-10 °C
-10 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
12.60 kW
13.30 kW
COP Tj = -7°C
3.13
2.67
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
8.30 kW
8.30 kW
COP Tj = +2°C
5.15
3.92
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
8.00 kW
7.90 kW
COP Tj = +7°C
6.57
5.12
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
9.10 kW
9.00 kW
COP Tj = 12°C
8.11
6.95
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
14.10 kW
15.20 kW
COP Tj = Tbiv
2.90
2.53
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
16.70 kW
18.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.66
2.37
WTOL
65 °C
65 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
38 W
38 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
20.59 kW
22.15 kW
Annual energy consumption Qhe
12796 kWh
16285 kWh
Pdh Tj = -15°C (if TOL<-20°C)
16.70
18.30
COP Tj = -15°C (if TOL<-20°C)
2.66
2.37
Cdh Tj = -15 °C
1.00
1.00
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.84 kW
7.36 kW
El input
1.54 kW
2.33 kW
COP
5.09
3.16
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
141 %
Prated
15.00 kW
15.00 kW
SCOP
4.63
3.59
Tbiv
-5 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.80 kW
13.26 kW
COP Tj = -7°C
2.98
2.48
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
8.30 kW
8.40 kW
COP Tj = +2°C
4.72
3.51
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
8.00 kW
7.80 kW
COP Tj = +7°C
6.16
4.61
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
9.10 kW
9.00 kW
COP Tj = 12°C
8.11
6.66
Cdh Tj = +12 °C
1.000
1.000
Pdh Tj = Tbiv
11.80 kW
12.50 kW
COP Tj = Tbiv
3.16
2.59
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.60 kW
13.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.87
2.28
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
65 °C
65 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
38 W
38 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.40 kW
1.60 kW
Annual energy consumption Qhe
6689 kWh
8620 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
M
Efficiency ηDHW
79 %
COP
1.72
Heating up time
1:53 h:min
Standby power input
79.0 W
Reference hot water temperature
52.7 °C
Mixed water at 40°C
350 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.84 kW
7.36 kW
El input
1.54 kW
2.33 kW
COP
5.09
3.16
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
141 %
Prated
15.00 kW
15.00 kW
SCOP
4.63
3.59
Tbiv
-5 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.80 kW
13.26 kW
COP Tj = -7°C
2.98
2.48
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
8.30 kW
8.40 kW
COP Tj = +2°C
4.72
3.51
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
8.00 kW
7.80 kW
COP Tj = +7°C
6.16
4.61
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
9.10 kW
9.00 kW
COP Tj = 12°C
8.11
6.66
Cdh Tj = +12 °C
1.000
1.000
Pdh Tj = Tbiv
11.80 kW
12.50 kW
COP Tj = Tbiv
3.16
2.59
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.60 kW
13.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.87
2.28
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
65 °C
65 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
38 W
38 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.40 kW
1.60 kW
Annual energy consumption Qhe
6689 kWh
8620 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
111 %
COP
2.60
Heating up time
1:49 h:min
Standby power input
79.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
362 l