Certificate holders

Subtype

Aquarea Hydro Split 5-7 kW STD (L Series)

Certificate Holder
Panasonic Marketing Europe GmbH
Hagenauer Strasse 43, Wiesbaden
65203 Wiesbaden
Germany
Registration number
011-1W0631
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Aquarea Hydro Split 5-7 kW STD (L Series)
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,960 kg

Certification Date
22.05.2023
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 11 (as of 2022-09)
Generate PDF Export model CSV
  • Number of models 16

Models

WH-ADC0509L3E5 / WH-WDG05LE5
Configure model
Model name
WH-ADC0509L3E5 / WH-WDG05LE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

5.00 kW

El input

0.99 kW

1.63 kW

COP

5.05

3.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.55 kW

1.00 kW

Cooling capacity

5.00

5.00

EER

3.23

5.00

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

5.00 kW

5.00 kW

SEER

5.14

7.06

Pdc Tj = 35°C

5.00 kW

5.00 kW

EER Tj = 35°C

3.23

5.00

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

3.68 kW

3.68 kW

EER Tj = 30°C

4.37

6.08

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

2.37 kW

2.86 kW

EER Tj = 25°C

6.22

8.76

Cdc Tj = 25 °C

0.990

0.990

Pdc Tj = 20°C

2.29 kW

2.77 kW

EER Tj = 20°C

6.89

9.37

Cdc Tj = 20 °C

0.990

0.990

Poff

9 W

9 W

PTO

2 W

2 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

340 kWh

248 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

237 %

168 %

Prated

5.00 kW

5.00 kW

SCOP

6.00

4.27

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.00 kW

5.00 kW

COP Tj = +2°C

3.52

2.34

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.20 kW

3.20 kW

COP Tj = +7°C

5.71

3.72

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

3.00 kW

2.80 kW

COP Tj = 12°C

7.12

5.49

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.52

2.34

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.52

2.34

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1113 kWh

1565 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

128 %

Prated

6.00 kW

6.00 kW

SCOP

4.25

3.28

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.60 kW

3.60 kW

COP Tj = -7°C

3.53

2.66

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.20 kW

2.20 kW

COP Tj = +2°C

5.20

3.97

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

6.59

5.25

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

3.00 kW

2.90 kW

COP Tj = 12°C

8.03

6.61

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

4.90 kW

4.90 kW

COP Tj = Tbiv

2.55

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.50 kW

4.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.96

1.53

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

2.00 kW

Annual energy consumption Qhe

3483 kWh

4516 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.90

4.90

COP Tj = -15°C (if TOL<-20°C)

2.55

2.01

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

142 %

Prated

5.00 kW

5.00 kW

SCOP

5.06

3.63

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.40 kW

4.40 kW

COP Tj = -7°C

3.25

2.27

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.70 kW

2.70 kW

COP Tj = +2°C

5.01

3.55

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.60 kW

2.40 kW

COP Tj = +7°C

6.44

4.69

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

3.00 kW

2.90 kW

COP Tj = 12°C

8.28

6.08

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

2.82

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

2.03

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2040 kWh

2849 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

160 %

COP

4.00

Heating up time

1:14 h:min

Standby power input

28.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

112 %

COP

2.80

Heating up time

1:14 h:min

Standby power input

36.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

148 %

COP

3.61

Heating up time

1:14 h:min

Standby power input

33.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

WH-ADC0509L3E5UK / WH-WDG05LE5
Configure model
Model name
WH-ADC0509L3E5UK / WH-WDG05LE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

5.00 kW

El input

0.99 kW

1.63 kW

COP

5.05

3.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.55 kW

1.00 kW

Cooling capacity

5.00

5.00

EER

3.23

5.00

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

5.00 kW

5.00 kW

SEER

5.14

7.06

Pdc Tj = 35°C

5.00 kW

5.00 kW

EER Tj = 35°C

3.23

5.00

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

3.68 kW

3.68 kW

EER Tj = 30°C

4.37

6.08

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

2.37 kW

2.86 kW

EER Tj = 25°C

6.22

8.76

Cdc Tj = 25 °C

0.990

0.990

Pdc Tj = 20°C

2.29 kW

2.77 kW

EER Tj = 20°C

6.89

9.37

Cdc Tj = 20 °C

0.990

0.990

Poff

9 W

9 W

PTO

2 W

2 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

340 kWh

248 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

237 %

168 %

Prated

5.00 kW

5.00 kW

SCOP

6.00

4.27

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.00 kW

5.00 kW

COP Tj = +2°C

3.52

2.34

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.20 kW

3.20 kW

COP Tj = +7°C

5.71

3.72

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

3.00 kW

2.80 kW

COP Tj = 12°C

7.12

5.49

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.52

2.34

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.52

2.34

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1113 kWh

1565 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

128 %

Prated

6.00 kW

6.00 kW

SCOP

4.25

3.28

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.60 kW

3.60 kW

COP Tj = -7°C

3.53

2.66

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.20 kW

2.20 kW

COP Tj = +2°C

5.20

3.97

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

6.59

5.25

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

3.00 kW

2.90 kW

COP Tj = 12°C

8.03

6.61

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

4.90 kW

4.90 kW

COP Tj = Tbiv

2.55

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.50 kW

4.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.96

1.53

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

2.00 kW

Annual energy consumption Qhe

3483 kWh

4516 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.90

4.90

COP Tj = -15°C (if TOL<-20°C)

2.55

2.01

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

142 %

Prated

5.00 kW

5.00 kW

SCOP

5.06

3.63

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.40 kW

4.40 kW

COP Tj = -7°C

3.25

2.27

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.70 kW

2.70 kW

COP Tj = +2°C

5.01

3.55

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.60 kW

2.40 kW

COP Tj = +7°C

6.44

4.69

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

3.00 kW

2.90 kW

COP Tj = 12°C

8.28

6.08

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

2.82

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

2.03

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2040 kWh

2849 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

160 %

COP

4.00

Heating up time

1:14 h:min

Standby power input

28.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

112 %

COP

2.80

Heating up time

1:14 h:min

Standby power input

36.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

148 %

COP

3.61

Heating up time

1:14 h:min

Standby power input

33.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

WH-ADC0509L3E5AN / WH-WDG05LE5
Configure model
Model name
WH-ADC0509L3E5AN / WH-WDG05LE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

5.00 kW

El input

0.99 kW

1.63 kW

COP

5.05

3.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.55 kW

1.00 kW

Cooling capacity

5.00

5.00

EER

3.23

5.00

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

5.00 kW

5.00 kW

SEER

5.14

7.06

Pdc Tj = 35°C

5.00 kW

5.00 kW

EER Tj = 35°C

3.23

5.00

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

3.68 kW

3.68 kW

EER Tj = 30°C

4.37

6.08

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

2.37 kW

2.86 kW

EER Tj = 25°C

6.22

8.76

Cdc Tj = 25 °C

0.990

0.990

Pdc Tj = 20°C

2.29 kW

2.77 kW

EER Tj = 20°C

6.89

9.37

Cdc Tj = 20 °C

0.990

0.990

Poff

9 W

9 W

PTO

2 W

2 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

340 kWh

248 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

237 %

168 %

Prated

5.00 kW

5.00 kW

SCOP

6.00

4.27

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.00 kW

5.00 kW

COP Tj = +2°C

3.52

2.34

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.20 kW

3.20 kW

COP Tj = +7°C

5.71

3.72

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

3.00 kW

2.80 kW

COP Tj = 12°C

7.12

5.49

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.52

2.34

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.52

2.34

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1113 kWh

1565 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

128 %

Prated

6.00 kW

6.00 kW

SCOP

4.25

3.28

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.60 kW

3.60 kW

COP Tj = -7°C

3.53

2.66

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.20 kW

2.20 kW

COP Tj = +2°C

5.20

3.97

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

6.59

5.25

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

3.00 kW

2.90 kW

COP Tj = 12°C

8.03

6.61

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

4.90 kW

4.90 kW

COP Tj = Tbiv

2.55

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.50 kW

4.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.96

1.53

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

2.00 kW

Annual energy consumption Qhe

3483 kWh

4516 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.90

4.90

COP Tj = -15°C (if TOL<-20°C)

2.55

2.01

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

142 %

Prated

5.00 kW

5.00 kW

SCOP

5.06

3.63

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.40 kW

4.40 kW

COP Tj = -7°C

3.25

2.27

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.70 kW

2.70 kW

COP Tj = +2°C

5.01

3.55

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.60 kW

2.40 kW

COP Tj = +7°C

6.44

4.69

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

3.00 kW

2.90 kW

COP Tj = 12°C

8.28

6.08

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

2.82

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

2.03

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2040 kWh

2849 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

160 %

COP

4.00

Heating up time

1:14 h:min

Standby power input

28.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

112 %

COP

2.80

Heating up time

1:14 h:min

Standby power input

36.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

148 %

COP

3.61

Heating up time

1:14 h:min

Standby power input

33.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

WH-ADC0509L3E5B / WH-WDG05LE5
Configure model
Model name
WH-ADC0509L3E5B / WH-WDG05LE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

5.00 kW

El input

0.99 kW

1.63 kW

COP

5.05

3.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.55 kW

1.00 kW

Cooling capacity

5.00

5.00

EER

3.23

5.00

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

5.00 kW

5.00 kW

SEER

5.14

7.06

Pdc Tj = 35°C

5.00 kW

5.00 kW

EER Tj = 35°C

3.23

5.00

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

3.68 kW

3.68 kW

EER Tj = 30°C

4.37

6.08

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

2.37 kW

2.86 kW

EER Tj = 25°C

6.22

8.76

Cdc Tj = 25 °C

0.990

0.990

Pdc Tj = 20°C

2.29 kW

2.77 kW

EER Tj = 20°C

6.89

9.37

Cdc Tj = 20 °C

0.990

0.990

Poff

9 W

9 W

PTO

2 W

2 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

340 kWh

248 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

237 %

168 %

Prated

5.00 kW

5.00 kW

SCOP

6.00

4.27

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.00 kW

5.00 kW

COP Tj = +2°C

3.52

2.34

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.20 kW

3.20 kW

COP Tj = +7°C

5.71

3.72

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

3.00 kW

2.80 kW

COP Tj = 12°C

7.12

5.49

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.52

2.34

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.52

2.34

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1113 kWh

1565 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

128 %

Prated

6.00 kW

6.00 kW

SCOP

4.25

3.28

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.60 kW

3.60 kW

COP Tj = -7°C

3.53

2.66

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.20 kW

2.20 kW

COP Tj = +2°C

5.20

3.97

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

6.59

5.25

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

3.00 kW

2.90 kW

COP Tj = 12°C

8.03

6.61

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

4.90 kW

4.90 kW

COP Tj = Tbiv

2.55

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.50 kW

4.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.96

1.53

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

2.00 kW

Annual energy consumption Qhe

3483 kWh

4516 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.90

4.90

COP Tj = -15°C (if TOL<-20°C)

2.55

2.01

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

142 %

Prated

5.00 kW

5.00 kW

SCOP

5.06

3.63

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.40 kW

4.40 kW

COP Tj = -7°C

3.25

2.27

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.70 kW

2.70 kW

COP Tj = +2°C

5.01

3.55

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.60 kW

2.40 kW

COP Tj = +7°C

6.44

4.69

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

3.00 kW

2.90 kW

COP Tj = 12°C

8.28

6.08

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

2.82

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

2.03

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2040 kWh

2849 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

160 %

COP

4.00

Heating up time

1:14 h:min

Standby power input

28.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

112 %

COP

2.80

Heating up time

1:14 h:min

Standby power input

36.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

148 %

COP

3.61

Heating up time

1:14 h:min

Standby power input

33.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

WH-ADC0509L6E5 / WH-WDG05LE5
Configure model
Model name
WH-ADC0509L6E5 / WH-WDG05LE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

5.00 kW

El input

0.99 kW

1.63 kW

COP

5.05

3.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.55 kW

1.00 kW

Cooling capacity

5.00

5.00

EER

3.23

5.00

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

5.00 kW

5.00 kW

SEER

5.14

7.06

Pdc Tj = 35°C

5.00 kW

5.00 kW

EER Tj = 35°C

3.23

5.00

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

3.68 kW

3.68 kW

EER Tj = 30°C

4.37

6.08

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

2.37 kW

2.86 kW

EER Tj = 25°C

6.22

8.76

Cdc Tj = 25 °C

0.990

0.990

Pdc Tj = 20°C

2.29 kW

2.77 kW

EER Tj = 20°C

6.89

9.37

Cdc Tj = 20 °C

0.990

0.990

Poff

9 W

9 W

PTO

2 W

2 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

340 kWh

248 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

237 %

168 %

Prated

5.00 kW

5.00 kW

SCOP

6.00

4.27

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.00 kW

5.00 kW

COP Tj = +2°C

3.52

2.34

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.20 kW

3.20 kW

COP Tj = +7°C

5.71

3.72

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

3.00 kW

2.80 kW

COP Tj = 12°C

7.12

5.49

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.52

2.34

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.52

2.34

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1113 kWh

1565 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

128 %

Prated

6.00 kW

6.00 kW

SCOP

4.25

3.28

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.60 kW

3.60 kW

COP Tj = -7°C

3.53

2.66

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.20 kW

2.20 kW

COP Tj = +2°C

5.20

3.97

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

6.59

5.25

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

3.00 kW

2.90 kW

COP Tj = 12°C

8.03

6.61

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

4.90 kW

4.90 kW

COP Tj = Tbiv

2.55

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.50 kW

4.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.96

1.53

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

2.00 kW

Annual energy consumption Qhe

3483 kWh

4516 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.90

4.90

COP Tj = -15°C (if TOL<-20°C)

2.55

2.01

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

142 %

Prated

5.00 kW

5.00 kW

SCOP

5.06

3.63

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.40 kW

4.40 kW

COP Tj = -7°C

3.25

2.27

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.70 kW

2.70 kW

COP Tj = +2°C

5.01

3.55

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.60 kW

2.40 kW

COP Tj = +7°C

6.44

4.69

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

3.00 kW

2.90 kW

COP Tj = 12°C

8.28

6.08

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

2.82

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

2.03

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2040 kWh

2849 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

160 %

COP

4.00

Heating up time

1:14 h:min

Standby power input

28.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

112 %

COP

2.80

Heating up time

1:14 h:min

Standby power input

36.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

148 %

COP

3.61

Heating up time

1:14 h:min

Standby power input

33.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

WH-ADC0509L6E5AN / WH-WDG05LE5
Configure model
Model name
WH-ADC0509L6E5AN / WH-WDG05LE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

5.00 kW

El input

0.99 kW

1.63 kW

COP

5.05

3.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.55 kW

1.00 kW

Cooling capacity

5.00

5.00

EER

3.23

5.00

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

5.00 kW

5.00 kW

SEER

5.14

7.06

Pdc Tj = 35°C

5.00 kW

5.00 kW

EER Tj = 35°C

3.23

5.00

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

3.68 kW

3.68 kW

EER Tj = 30°C

4.37

6.08

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

2.37 kW

2.86 kW

EER Tj = 25°C

6.22

8.76

Cdc Tj = 25 °C

0.990

0.990

Pdc Tj = 20°C

2.29 kW

2.77 kW

EER Tj = 20°C

6.89

9.37

Cdc Tj = 20 °C

0.990

0.990

Poff

9 W

9 W

PTO

2 W

2 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

340 kWh

248 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

237 %

168 %

Prated

5.00 kW

5.00 kW

SCOP

6.00

4.27

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.00 kW

5.00 kW

COP Tj = +2°C

3.52

2.34

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.20 kW

3.20 kW

COP Tj = +7°C

5.71

3.72

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

3.00 kW

2.80 kW

COP Tj = 12°C

7.12

5.49

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.52

2.34

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.52

2.34

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1113 kWh

1565 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

128 %

Prated

6.00 kW

6.00 kW

SCOP

4.25

3.28

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.60 kW

3.60 kW

COP Tj = -7°C

3.53

2.66

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.20 kW

2.20 kW

COP Tj = +2°C

5.20

3.97

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

6.59

5.25

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

3.00 kW

2.90 kW

COP Tj = 12°C

8.03

6.61

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

4.90 kW

4.90 kW

COP Tj = Tbiv

2.55

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.50 kW

4.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.96

1.53

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

2.00 kW

Annual energy consumption Qhe

3483 kWh

4516 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.90

4.90

COP Tj = -15°C (if TOL<-20°C)

2.55

2.01

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

142 %

Prated

5.00 kW

5.00 kW

SCOP

5.06

3.63

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.40 kW

4.40 kW

COP Tj = -7°C

3.25

2.27

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.70 kW

2.70 kW

COP Tj = +2°C

5.01

3.55

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.60 kW

2.40 kW

COP Tj = +7°C

6.44

4.69

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

3.00 kW

2.90 kW

COP Tj = 12°C

8.28

6.08

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

2.82

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

2.03

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2040 kWh

2849 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

160 %

COP

4.00

Heating up time

1:14 h:min

Standby power input

28.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

112 %

COP

2.80

Heating up time

1:14 h:min

Standby power input

36.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

148 %

COP

3.61

Heating up time

1:14 h:min

Standby power input

33.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

WH-SDC0509L3E5 / WH-WDG05LE5
Configure model
Model name
WH-SDC0509L3E5 / WH-WDG05LE5
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

5.00 kW

El input

0.99 kW

1.63 kW

COP

5.05

3.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.55 kW

1.00 kW

Cooling capacity

5.00

5.00

EER

3.23

5.00

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

5.00 kW

5.00 kW

SEER

5.14

7.06

Pdc Tj = 35°C

5.00 kW

5.00 kW

EER Tj = 35°C

3.23

5.00

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

3.68 kW

3.68 kW

EER Tj = 30°C

4.37

6.08

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

2.37 kW

2.86 kW

EER Tj = 25°C

6.22

8.76

Cdc Tj = 25 °C

0.990

0.990

Pdc Tj = 20°C

2.29 kW

2.77 kW

EER Tj = 20°C

6.89

9.37

Cdc Tj = 20 °C

0.990

0.990

Poff

9 W

9 W

PTO

2 W

2 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

340 kWh

248 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

237 %

168 %

Prated

5.00 kW

5.00 kW

SCOP

6.00

4.27

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.00 kW

5.00 kW

COP Tj = +2°C

3.52

2.34

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.20 kW

3.20 kW

COP Tj = +7°C

5.71

3.72

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

3.00 kW

2.80 kW

COP Tj = 12°C

7.12

5.49

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.52

2.34

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.52

2.34

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1113 kWh

1565 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

128 %

Prated

6.00 kW

6.00 kW

SCOP

4.25

3.28

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.60 kW

3.60 kW

COP Tj = -7°C

3.53

2.66

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.20 kW

2.20 kW

COP Tj = +2°C

5.20

3.97

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

6.59

5.25

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

3.00 kW

2.90 kW

COP Tj = 12°C

8.03

6.61

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

4.90 kW

4.90 kW

COP Tj = Tbiv

2.55

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.50 kW

4.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.96

1.53

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

2.00 kW

Annual energy consumption Qhe

3483 kWh

4516 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.90

4.90

COP Tj = -15°C (if TOL<-20°C)

2.55

2.01

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

142 %

Prated

5.00 kW

5.00 kW

SCOP

5.06

3.63

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.40 kW

4.40 kW

COP Tj = -7°C

3.25

2.27

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.70 kW

2.70 kW

COP Tj = +2°C

5.01

3.55

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.60 kW

2.40 kW

COP Tj = +7°C

6.44

4.69

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

3.00 kW

2.90 kW

COP Tj = 12°C

8.28

6.08

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

2.82

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

2.03

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2040 kWh

2849 kWh

WH-SDC0509L6E5 / WH-WDG05LE5
Configure model
Model name
WH-SDC0509L6E5 / WH-WDG05LE5
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

5.00 kW

El input

0.99 kW

1.63 kW

COP

5.05

3.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.55 kW

1.00 kW

Cooling capacity

5.00

5.00

EER

3.23

5.00

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

5.00 kW

5.00 kW

SEER

5.14

7.06

Pdc Tj = 35°C

5.00 kW

5.00 kW

EER Tj = 35°C

3.23

5.00

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

3.68 kW

3.68 kW

EER Tj = 30°C

4.37

6.08

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

2.37 kW

2.86 kW

EER Tj = 25°C

6.22

8.76

Cdc Tj = 25 °C

0.990

0.990

Pdc Tj = 20°C

2.29 kW

2.77 kW

EER Tj = 20°C

6.89

9.37

Cdc Tj = 20 °C

0.990

0.990

Poff

9 W

9 W

PTO

2 W

2 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

340 kWh

248 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

237 %

168 %

Prated

5.00 kW

5.00 kW

SCOP

6.00

4.27

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.00 kW

5.00 kW

COP Tj = +2°C

3.52

2.34

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.20 kW

3.20 kW

COP Tj = +7°C

5.71

3.72

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

3.00 kW

2.80 kW

COP Tj = 12°C

7.12

5.49

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.52

2.34

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.52

2.34

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1113 kWh

1565 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

128 %

Prated

6.00 kW

6.00 kW

SCOP

4.25

3.28

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.60 kW

3.60 kW

COP Tj = -7°C

3.53

2.66

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.20 kW

2.20 kW

COP Tj = +2°C

5.20

3.97

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

6.59

5.25

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

3.00 kW

2.90 kW

COP Tj = 12°C

8.03

6.61

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

4.90 kW

4.90 kW

COP Tj = Tbiv

2.55

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.50 kW

4.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.96

1.53

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

2.00 kW

Annual energy consumption Qhe

3483 kWh

4516 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.90

4.90

COP Tj = -15°C (if TOL<-20°C)

2.55

2.01

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

142 %

Prated

5.00 kW

5.00 kW

SCOP

5.06

3.63

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.40 kW

4.40 kW

COP Tj = -7°C

3.25

2.27

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.70 kW

2.70 kW

COP Tj = +2°C

5.01

3.55

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.60 kW

2.40 kW

COP Tj = +7°C

6.44

4.69

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

3.00 kW

2.90 kW

COP Tj = 12°C

8.28

6.08

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

2.82

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

2.03

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2040 kWh

2849 kWh

WH-ADC0509L3E5 / WH-WDG07LE5
Configure model
Model name
WH-ADC0509L3E5 / WH-WDG07LE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.00 kW

7.00 kW

El input

1.42 kW

2.35 kW

COP

4.93

2.98

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.31 kW

1.48 kW

Cooling capacity

7.00

7.00

EER

3.03

4.73

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.00 kW

7.00 kW

SEER

5.08

6.93

Pdc Tj = 35°C

7.00 kW

7.00 kW

EER Tj = 35°C

3.03

4.73

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

5.16 kW

5.16 kW

EER Tj = 30°C

4.48

6.25

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

3.32 kW

3.32 kW

EER Tj = 25°C

6.06

8.07

Cdc Tj = 25 °C

1.000

1.000

Pdc Tj = 20°C

2.71 kW

3.41 kW

EER Tj = 20°C

6.32

8.78

Cdc Tj = 20 °C

1.000

1.000

Poff

9 W

9 W

PTO

2 W

2 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

482 kWh

354 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

178 %

Prated

7.00 kW

6.00 kW

SCOP

6.31

4.52

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.00 kW

6.00 kW

COP Tj = +2°C

3.47

2.47

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.50 kW

3.90 kW

COP Tj = +7°C

5.95

3.90

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.30 kW

3.20 kW

COP Tj = 12°C

7.47

5.83

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

7.00 kW

6.00 kW

COP Tj = Tbiv

3.47

2.47

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.47

2.47

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1483 kWh

1775 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

129 %

Prated

7.00 kW

7.00 kW

SCOP

4.25

3.29

Tbiv

-17 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.20 kW

4.20 kW

COP Tj = -7°C

3.69

2.77

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.60 kW

2.60 kW

COP Tj = +2°C

4.92

3.81

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.80 kW

2.80 kW

COP Tj = +7°C

6.39

5.33

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.20 kW

3.30 kW

COP Tj = 12°C

7.50

6.94

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

6.10 kW

5.70 kW

COP Tj = Tbiv

2.41

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.30 kW

4.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.04

1.60

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.70 kW

2.30 kW

Annual energy consumption Qhe

4060 kWh

5241 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

5.70

COP Tj = -15°C (if TOL<-20°C)

2.64

2.09

Cdh Tj = -15 °C

0.990

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

142 %

Prated

7.00 kW

7.00 kW

SCOP

4.96

3.62

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.20 kW

6.20 kW

COP Tj = -7°C

3.26

2.33

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

3.80 kW

3.80 kW

COP Tj = +2°C

4.83

3.49

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.90 kW

2.70 kW

COP Tj = +7°C

6.29

4.66

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

7.92

6.37

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

7.00 kW

6.20 kW

COP Tj = Tbiv

2.83

2.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.83

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.80 kW

Annual energy consumption Qhe

2916 kWh

3991 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

160 %

COP

4.00

Heating up time

1:04 h:min

Standby power input

28.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

112 %

COP

2.80

Heating up time

1:04 h:min

Standby power input

36.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

148 %

COP

3.61

Heating up time

1:04 h:min

Standby power input

33.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

WH-ADC0509L3E5UK / WH-WDG07LE5
Configure model
Model name
WH-ADC0509L3E5UK / WH-WDG07LE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.00 kW

7.00 kW

El input

1.42 kW

2.35 kW

COP

4.93

2.98

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.31 kW

1.48 kW

Cooling capacity

7.00

7.00

EER

3.03

4.73

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.00 kW

7.00 kW

SEER

5.08

6.93

Pdc Tj = 35°C

7.00 kW

7.00 kW

EER Tj = 35°C

3.03

4.73

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

5.16 kW

5.16 kW

EER Tj = 30°C

4.48

6.25

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

3.32 kW

3.32 kW

EER Tj = 25°C

6.06

8.07

Cdc Tj = 25 °C

1.000

1.000

Pdc Tj = 20°C

2.71 kW

3.41 kW

EER Tj = 20°C

6.32

8.78

Cdc Tj = 20 °C

1.000

1.000

Poff

9 W

9 W

PTO

2 W

2 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

482 kWh

354 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

178 %

Prated

7.00 kW

6.00 kW

SCOP

6.31

4.52

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.00 kW

6.00 kW

COP Tj = +2°C

3.47

2.47

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.50 kW

3.90 kW

COP Tj = +7°C

5.95

3.90

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.30 kW

3.20 kW

COP Tj = 12°C

7.47

5.83

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

7.00 kW

6.00 kW

COP Tj = Tbiv

3.47

2.47

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.47

2.47

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1483 kWh

1775 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

129 %

Prated

7.00 kW

7.00 kW

SCOP

4.25

3.29

Tbiv

-17 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.20 kW

4.20 kW

COP Tj = -7°C

3.69

2.77

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.60 kW

2.60 kW

COP Tj = +2°C

4.92

3.81

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.80 kW

2.80 kW

COP Tj = +7°C

6.39

5.33

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.20 kW

3.30 kW

COP Tj = 12°C

7.50

6.94

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

6.10 kW

5.70 kW

COP Tj = Tbiv

2.41

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.30 kW

4.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.04

1.60

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.70 kW

2.30 kW

Annual energy consumption Qhe

4060 kWh

5241 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

5.70

COP Tj = -15°C (if TOL<-20°C)

2.64

2.09

Cdh Tj = -15 °C

0.990

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

142 %

Prated

7.00 kW

7.00 kW

SCOP

4.96

3.62

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.20 kW

6.20 kW

COP Tj = -7°C

3.26

2.33

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

3.80 kW

3.80 kW

COP Tj = +2°C

4.83

3.49

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.90 kW

2.70 kW

COP Tj = +7°C

6.29

4.66

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

7.92

6.37

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

7.00 kW

6.20 kW

COP Tj = Tbiv

2.83

2.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.83

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.80 kW

Annual energy consumption Qhe

2916 kWh

3991 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

160 %

COP

4.00

Heating up time

1:04 h:min

Standby power input

28.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

112 %

COP

2.80

Heating up time

1:04 h:min

Standby power input

36.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

148 %

COP

3.61

Heating up time

1:04 h:min

Standby power input

33.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

WH-ADC0509L3E5AN / WH-WDG07LE5
Configure model
Model name
WH-ADC0509L3E5AN / WH-WDG07LE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.00 kW

7.00 kW

El input

1.42 kW

2.35 kW

COP

4.93

2.98

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.31 kW

1.48 kW

Cooling capacity

7.00

7.00

EER

3.03

4.73

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.00 kW

7.00 kW

SEER

5.08

6.93

Pdc Tj = 35°C

7.00 kW

7.00 kW

EER Tj = 35°C

3.03

4.73

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

5.16 kW

5.16 kW

EER Tj = 30°C

4.48

6.25

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

3.32 kW

3.32 kW

EER Tj = 25°C

6.06

8.07

Cdc Tj = 25 °C

1.000

1.000

Pdc Tj = 20°C

2.71 kW

3.41 kW

EER Tj = 20°C

6.32

8.78

Cdc Tj = 20 °C

1.000

1.000

Poff

9 W

9 W

PTO

2 W

2 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

482 kWh

354 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

178 %

Prated

7.00 kW

6.00 kW

SCOP

6.31

4.52

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.00 kW

6.00 kW

COP Tj = +2°C

3.47

2.47

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.50 kW

3.90 kW

COP Tj = +7°C

5.95

3.90

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.30 kW

3.20 kW

COP Tj = 12°C

7.47

5.83

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

7.00 kW

6.00 kW

COP Tj = Tbiv

3.47

2.47

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.47

2.47

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1483 kWh

1775 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

129 %

Prated

7.00 kW

7.00 kW

SCOP

4.25

3.29

Tbiv

-17 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.20 kW

4.20 kW

COP Tj = -7°C

3.69

2.77

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.60 kW

2.60 kW

COP Tj = +2°C

4.92

3.81

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.80 kW

2.80 kW

COP Tj = +7°C

6.39

5.33

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.20 kW

3.30 kW

COP Tj = 12°C

7.50

6.94

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

6.10 kW

5.70 kW

COP Tj = Tbiv

2.41

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.30 kW

4.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.04

1.60

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.70 kW

2.30 kW

Annual energy consumption Qhe

4060 kWh

5241 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

5.70

COP Tj = -15°C (if TOL<-20°C)

2.64

2.09

Cdh Tj = -15 °C

0.990

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

142 %

Prated

7.00 kW

7.00 kW

SCOP

4.96

3.62

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.20 kW

6.20 kW

COP Tj = -7°C

3.26

2.33

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

3.80 kW

3.80 kW

COP Tj = +2°C

4.83

3.49

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.90 kW

2.70 kW

COP Tj = +7°C

6.29

4.66

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

7.92

6.37

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

7.00 kW

6.20 kW

COP Tj = Tbiv

2.83

2.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.83

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.80 kW

Annual energy consumption Qhe

2916 kWh

3991 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

160 %

COP

4.00

Heating up time

1:04 h:min

Standby power input

28.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

112 %

COP

2.80

Heating up time

1:04 h:min

Standby power input

36.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

148 %

COP

3.61

Heating up time

1:04 h:min

Standby power input

33.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

WH-ADC0509L3E5B / WH-WDG07LE5
Configure model
Model name
WH-ADC0509L3E5B / WH-WDG07LE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.00 kW

7.00 kW

El input

1.42 kW

2.35 kW

COP

4.93

2.98

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.31 kW

1.48 kW

Cooling capacity

7.00

7.00

EER

3.03

4.73

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.00 kW

7.00 kW

SEER

5.08

6.93

Pdc Tj = 35°C

7.00 kW

7.00 kW

EER Tj = 35°C

3.03

4.73

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

5.16 kW

5.16 kW

EER Tj = 30°C

4.48

6.25

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

3.32 kW

3.32 kW

EER Tj = 25°C

6.06

8.07

Cdc Tj = 25 °C

1.000

1.000

Pdc Tj = 20°C

2.71 kW

3.41 kW

EER Tj = 20°C

6.32

8.78

Cdc Tj = 20 °C

1.000

1.000

Poff

9 W

9 W

PTO

2 W

2 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

482 kWh

354 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

178 %

Prated

7.00 kW

6.00 kW

SCOP

6.31

4.52

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.00 kW

6.00 kW

COP Tj = +2°C

3.47

2.47

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.50 kW

3.90 kW

COP Tj = +7°C

5.95

3.90

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.30 kW

3.20 kW

COP Tj = 12°C

7.47

5.83

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

7.00 kW

6.00 kW

COP Tj = Tbiv

3.47

2.47

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.47

2.47

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1483 kWh

1775 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

129 %

Prated

7.00 kW

7.00 kW

SCOP

4.25

3.29

Tbiv

-17 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.20 kW

4.20 kW

COP Tj = -7°C

3.69

2.77

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.60 kW

2.60 kW

COP Tj = +2°C

4.92

3.81

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.80 kW

2.80 kW

COP Tj = +7°C

6.39

5.33

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.20 kW

3.30 kW

COP Tj = 12°C

7.50

6.94

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

6.10 kW

5.70 kW

COP Tj = Tbiv

2.41

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.30 kW

4.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.04

1.60

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.70 kW

2.30 kW

Annual energy consumption Qhe

4060 kWh

5241 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

5.70

COP Tj = -15°C (if TOL<-20°C)

2.64

2.09

Cdh Tj = -15 °C

0.990

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

142 %

Prated

7.00 kW

7.00 kW

SCOP

4.96

3.62

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.20 kW

6.20 kW

COP Tj = -7°C

3.26

2.33

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

3.80 kW

3.80 kW

COP Tj = +2°C

4.83

3.49

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.90 kW

2.70 kW

COP Tj = +7°C

6.29

4.66

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

7.92

6.37

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

7.00 kW

6.20 kW

COP Tj = Tbiv

2.83

2.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.83

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.80 kW

Annual energy consumption Qhe

2916 kWh

3991 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

160 %

COP

4.00

Heating up time

1:04 h:min

Standby power input

28.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

112 %

COP

2.80

Heating up time

1:04 h:min

Standby power input

36.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

148 %

COP

3.61

Heating up time

1:04 h:min

Standby power input

33.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

WH-ADC0509L6E5 / WH-WDG07LE5
Configure model
Model name
WH-ADC0509L6E5 / WH-WDG07LE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.00 kW

7.00 kW

El input

1.42 kW

2.35 kW

COP

4.93

2.98

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.31 kW

1.48 kW

Cooling capacity

7.00

7.00

EER

3.03

4.73

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.00 kW

7.00 kW

SEER

5.08

6.93

Pdc Tj = 35°C

7.00 kW

7.00 kW

EER Tj = 35°C

3.03

4.73

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

5.16 kW

5.16 kW

EER Tj = 30°C

4.48

6.25

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

3.32 kW

3.32 kW

EER Tj = 25°C

6.06

8.07

Cdc Tj = 25 °C

1.000

1.000

Pdc Tj = 20°C

2.71 kW

3.41 kW

EER Tj = 20°C

6.32

8.78

Cdc Tj = 20 °C

1.000

1.000

Poff

9 W

9 W

PTO

2 W

2 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

482 kWh

354 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

178 %

Prated

7.00 kW

6.00 kW

SCOP

6.31

4.52

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.00 kW

6.00 kW

COP Tj = +2°C

3.47

2.47

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.50 kW

3.90 kW

COP Tj = +7°C

5.95

3.90

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.30 kW

3.20 kW

COP Tj = 12°C

7.47

5.83

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

7.00 kW

6.00 kW

COP Tj = Tbiv

3.47

2.47

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.47

2.47

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1483 kWh

1775 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

129 %

Prated

7.00 kW

7.00 kW

SCOP

4.25

3.29

Tbiv

-17 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.20 kW

4.20 kW

COP Tj = -7°C

3.69

2.77

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.60 kW

2.60 kW

COP Tj = +2°C

4.92

3.81

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.80 kW

2.80 kW

COP Tj = +7°C

6.39

5.33

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.20 kW

3.30 kW

COP Tj = 12°C

7.50

6.94

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

6.10 kW

5.70 kW

COP Tj = Tbiv

2.41

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.30 kW

4.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.04

1.60

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.70 kW

2.30 kW

Annual energy consumption Qhe

4060 kWh

5241 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

5.70

COP Tj = -15°C (if TOL<-20°C)

2.64

2.09

Cdh Tj = -15 °C

0.990

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

142 %

Prated

7.00 kW

7.00 kW

SCOP

4.96

3.62

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.20 kW

6.20 kW

COP Tj = -7°C

3.26

2.33

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

3.80 kW

3.80 kW

COP Tj = +2°C

4.83

3.49

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.90 kW

2.70 kW

COP Tj = +7°C

6.29

4.66

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

7.92

6.37

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

7.00 kW

6.20 kW

COP Tj = Tbiv

2.83

2.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.83

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.80 kW

Annual energy consumption Qhe

2916 kWh

3991 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

160 %

COP

4.00

Heating up time

1:04 h:min

Standby power input

28.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

112 %

COP

2.80

Heating up time

1:04 h:min

Standby power input

36.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

148 %

COP

3.61

Heating up time

1:04 h:min

Standby power input

33.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

WH-ADC0509L6E5AN / WH-WDG07LE5
Configure model
Model name
WH-ADC0509L6E5AN / WH-WDG07LE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.00 kW

7.00 kW

El input

1.42 kW

2.35 kW

COP

4.93

2.98

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.31 kW

1.48 kW

Cooling capacity

7.00

7.00

EER

3.03

4.73

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.00 kW

7.00 kW

SEER

5.08

6.93

Pdc Tj = 35°C

7.00 kW

7.00 kW

EER Tj = 35°C

3.03

4.73

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

5.16 kW

5.16 kW

EER Tj = 30°C

4.48

6.25

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

3.32 kW

3.32 kW

EER Tj = 25°C

6.06

8.07

Cdc Tj = 25 °C

1.000

1.000

Pdc Tj = 20°C

2.71 kW

3.41 kW

EER Tj = 20°C

6.32

8.78

Cdc Tj = 20 °C

1.000

1.000

Poff

9 W

9 W

PTO

2 W

2 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

482 kWh

354 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

178 %

Prated

7.00 kW

6.00 kW

SCOP

6.31

4.52

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.00 kW

6.00 kW

COP Tj = +2°C

3.47

2.47

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.50 kW

3.90 kW

COP Tj = +7°C

5.95

3.90

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.30 kW

3.20 kW

COP Tj = 12°C

7.47

5.83

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

7.00 kW

6.00 kW

COP Tj = Tbiv

3.47

2.47

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.47

2.47

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1483 kWh

1775 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

129 %

Prated

7.00 kW

7.00 kW

SCOP

4.25

3.29

Tbiv

-17 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.20 kW

4.20 kW

COP Tj = -7°C

3.69

2.77

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.60 kW

2.60 kW

COP Tj = +2°C

4.92

3.81

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.80 kW

2.80 kW

COP Tj = +7°C

6.39

5.33

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.20 kW

3.30 kW

COP Tj = 12°C

7.50

6.94

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

6.10 kW

5.70 kW

COP Tj = Tbiv

2.41

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.30 kW

4.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.04

1.60

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.70 kW

2.30 kW

Annual energy consumption Qhe

4060 kWh

5241 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

5.70

COP Tj = -15°C (if TOL<-20°C)

2.64

2.09

Cdh Tj = -15 °C

0.990

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

142 %

Prated

7.00 kW

7.00 kW

SCOP

4.96

3.62

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.20 kW

6.20 kW

COP Tj = -7°C

3.26

2.33

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

3.80 kW

3.80 kW

COP Tj = +2°C

4.83

3.49

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.90 kW

2.70 kW

COP Tj = +7°C

6.29

4.66

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

7.92

6.37

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

7.00 kW

6.20 kW

COP Tj = Tbiv

2.83

2.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.83

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.80 kW

Annual energy consumption Qhe

2916 kWh

3991 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

160 %

COP

4.00

Heating up time

1:04 h:min

Standby power input

28.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

112 %

COP

2.80

Heating up time

1:04 h:min

Standby power input

36.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

148 %

COP

3.61

Heating up time

1:04 h:min

Standby power input

33.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

251 l

WH-SDC0509L3E5 / WH-WDG07LE5
Configure model
Model name
WH-SDC0509L3E5 / WH-WDG07LE5
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.00 kW

7.00 kW

El input

1.42 kW

2.35 kW

COP

4.93

2.98

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.31 kW

1.48 kW

Cooling capacity

7.00

7.00

EER

3.03

4.73

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.00 kW

7.00 kW

SEER

5.08

6.93

Pdc Tj = 35°C

7.00 kW

7.00 kW

EER Tj = 35°C

3.03

4.73

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

5.16 kW

5.16 kW

EER Tj = 30°C

4.48

6.25

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

3.32 kW

3.32 kW

EER Tj = 25°C

6.06

8.07

Cdc Tj = 25 °C

1.000

1.000

Pdc Tj = 20°C

2.71 kW

3.41 kW

EER Tj = 20°C

6.32

8.78

Cdc Tj = 20 °C

1.000

1.000

Poff

9 W

9 W

PTO

2 W

2 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

482 kWh

354 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

178 %

Prated

7.00 kW

6.00 kW

SCOP

6.31

4.52

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.00 kW

6.00 kW

COP Tj = +2°C

3.47

2.47

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.50 kW

3.90 kW

COP Tj = +7°C

5.95

3.90

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.30 kW

3.20 kW

COP Tj = 12°C

7.47

5.83

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

7.00 kW

6.00 kW

COP Tj = Tbiv

3.47

2.47

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.47

2.47

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1483 kWh

1775 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

129 %

Prated

7.00 kW

7.00 kW

SCOP

4.25

3.29

Tbiv

-17 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.20 kW

4.20 kW

COP Tj = -7°C

3.69

2.77

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.60 kW

2.60 kW

COP Tj = +2°C

4.92

3.81

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.80 kW

2.80 kW

COP Tj = +7°C

6.39

5.33

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.20 kW

3.30 kW

COP Tj = 12°C

7.50

6.94

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

6.10 kW

5.70 kW

COP Tj = Tbiv

2.41

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.30 kW

4.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.04

1.60

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.70 kW

2.30 kW

Annual energy consumption Qhe

4060 kWh

5241 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

5.70

COP Tj = -15°C (if TOL<-20°C)

2.64

2.09

Cdh Tj = -15 °C

0.990

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

142 %

Prated

7.00 kW

7.00 kW

SCOP

4.96

3.62

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.20 kW

6.20 kW

COP Tj = -7°C

3.26

2.33

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

3.80 kW

3.80 kW

COP Tj = +2°C

4.83

3.49

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.90 kW

2.70 kW

COP Tj = +7°C

6.29

4.66

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

7.92

6.37

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

7.00 kW

6.20 kW

COP Tj = Tbiv

2.83

2.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.83

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.80 kW

Annual energy consumption Qhe

2916 kWh

3991 kWh

WH-SDC0509L6E5 / WH-WDG07LE5
Configure model
Model name
WH-SDC0509L6E5 / WH-WDG07LE5
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.00 kW

7.00 kW

El input

1.42 kW

2.35 kW

COP

4.93

2.98

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.31 kW

1.48 kW

Cooling capacity

7.00

7.00

EER

3.03

4.73

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.00 kW

7.00 kW

SEER

5.08

6.93

Pdc Tj = 35°C

7.00 kW

7.00 kW

EER Tj = 35°C

3.03

4.73

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

5.16 kW

5.16 kW

EER Tj = 30°C

4.48

6.25

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

3.32 kW

3.32 kW

EER Tj = 25°C

6.06

8.07

Cdc Tj = 25 °C

1.000

1.000

Pdc Tj = 20°C

2.71 kW

3.41 kW

EER Tj = 20°C

6.32

8.78

Cdc Tj = 20 °C

1.000

1.000

Poff

9 W

9 W

PTO

2 W

2 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

482 kWh

354 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

178 %

Prated

7.00 kW

6.00 kW

SCOP

6.31

4.52

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.00 kW

6.00 kW

COP Tj = +2°C

3.47

2.47

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.50 kW

3.90 kW

COP Tj = +7°C

5.95

3.90

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.30 kW

3.20 kW

COP Tj = 12°C

7.47

5.83

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

7.00 kW

6.00 kW

COP Tj = Tbiv

3.47

2.47

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.47

2.47

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1483 kWh

1775 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

129 %

Prated

7.00 kW

7.00 kW

SCOP

4.25

3.29

Tbiv

-17 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.20 kW

4.20 kW

COP Tj = -7°C

3.69

2.77

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.60 kW

2.60 kW

COP Tj = +2°C

4.92

3.81

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.80 kW

2.80 kW

COP Tj = +7°C

6.39

5.33

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.20 kW

3.30 kW

COP Tj = 12°C

7.50

6.94

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

6.10 kW

5.70 kW

COP Tj = Tbiv

2.41

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.30 kW

4.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.04

1.60

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.70 kW

2.30 kW

Annual energy consumption Qhe

4060 kWh

5241 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

5.70

COP Tj = -15°C (if TOL<-20°C)

2.64

2.09

Cdh Tj = -15 °C

0.990

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

142 %

Prated

7.00 kW

7.00 kW

SCOP

4.96

3.62

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.20 kW

6.20 kW

COP Tj = -7°C

3.26

2.33

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

3.80 kW

3.80 kW

COP Tj = +2°C

4.83

3.49

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.90 kW

2.70 kW

COP Tj = +7°C

6.29

4.66

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

7.92

6.37

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

7.00 kW

6.20 kW

COP Tj = Tbiv

2.83

2.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.83

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

13 W

13 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.80 kW

Annual energy consumption Qhe

2916 kWh

3991 kWh