0,960 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.00 kW
5.00 kW
El input
0.99 kW
1.63 kW
COP
5.05
3.07
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.55 kW
1.00 kW
Cooling capacity
5.00
5.00
EER
3.23
5.00
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.00 kW
5.00 kW
SEER
5.14
7.06
Pdc Tj = 35°C
5.00 kW
5.00 kW
EER Tj = 35°C
3.23
5.00
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
3.68 kW
3.68 kW
EER Tj = 30°C
4.37
6.08
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
2.37 kW
2.86 kW
EER Tj = 25°C
6.22
8.76
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
2.29 kW
2.77 kW
EER Tj = 20°C
6.89
9.37
Cdc Tj = 20 °C
0.990
0.990
Poff
9 W
9 W
PTO
2 W
2 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
340 kWh
248 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
237 %
168 %
Prated
5.00 kW
5.00 kW
SCOP
6.00
4.27
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.00 kW
5.00 kW
COP Tj = +2°C
3.52
2.34
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.20 kW
3.20 kW
COP Tj = +7°C
5.71
3.72
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
3.00 kW
2.80 kW
COP Tj = 12°C
7.12
5.49
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
5.00 kW
5.00 kW
COP Tj = Tbiv
3.52
2.34
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
5.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.52
2.34
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1113 kWh
1565 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
128 %
Prated
6.00 kW
6.00 kW
SCOP
4.25
3.28
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.60 kW
3.60 kW
COP Tj = -7°C
3.53
2.66
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.20 kW
2.20 kW
COP Tj = +2°C
5.20
3.97
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
2.60 kW
2.50 kW
COP Tj = +7°C
6.59
5.25
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
3.00 kW
2.90 kW
COP Tj = 12°C
8.03
6.61
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
4.90 kW
4.90 kW
COP Tj = Tbiv
2.55
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.50 kW
4.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.96
1.53
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.50 kW
2.00 kW
Annual energy consumption Qhe
3483 kWh
4516 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.90
4.90
COP Tj = -15°C (if TOL<-20°C)
2.55
2.01
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
142 %
Prated
5.00 kW
5.00 kW
SCOP
5.06
3.63
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.40 kW
4.40 kW
COP Tj = -7°C
3.25
2.27
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.70 kW
2.70 kW
COP Tj = +2°C
5.01
3.55
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.60 kW
2.40 kW
COP Tj = +7°C
6.44
4.69
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
3.00 kW
2.90 kW
COP Tj = 12°C
8.28
6.08
Cdh Tj = +12 °C
0.960
0.970
Pdh Tj = Tbiv
5.00 kW
5.00 kW
COP Tj = Tbiv
2.82
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
5.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.82
2.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2040 kWh
2849 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
160 %
COP
4.00
Heating up time
1:14 h:min
Standby power input
28.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
112 %
COP
2.80
Heating up time
1:14 h:min
Standby power input
36.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
148 %
COP
3.61
Heating up time
1:14 h:min
Standby power input
33.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.00 kW
5.00 kW
El input
0.99 kW
1.63 kW
COP
5.05
3.07
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.55 kW
1.00 kW
Cooling capacity
5.00
5.00
EER
3.23
5.00
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.00 kW
5.00 kW
SEER
5.14
7.06
Pdc Tj = 35°C
5.00 kW
5.00 kW
EER Tj = 35°C
3.23
5.00
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
3.68 kW
3.68 kW
EER Tj = 30°C
4.37
6.08
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
2.37 kW
2.86 kW
EER Tj = 25°C
6.22
8.76
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
2.29 kW
2.77 kW
EER Tj = 20°C
6.89
9.37
Cdc Tj = 20 °C
0.990
0.990
Poff
9 W
9 W
PTO
2 W
2 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
340 kWh
248 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
237 %
168 %
Prated
5.00 kW
5.00 kW
SCOP
6.00
4.27
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.00 kW
5.00 kW
COP Tj = +2°C
3.52
2.34
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.20 kW
3.20 kW
COP Tj = +7°C
5.71
3.72
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
3.00 kW
2.80 kW
COP Tj = 12°C
7.12
5.49
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
5.00 kW
5.00 kW
COP Tj = Tbiv
3.52
2.34
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
5.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.52
2.34
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1113 kWh
1565 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
128 %
Prated
6.00 kW
6.00 kW
SCOP
4.25
3.28
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.60 kW
3.60 kW
COP Tj = -7°C
3.53
2.66
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.20 kW
2.20 kW
COP Tj = +2°C
5.20
3.97
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
2.60 kW
2.50 kW
COP Tj = +7°C
6.59
5.25
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
3.00 kW
2.90 kW
COP Tj = 12°C
8.03
6.61
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
4.90 kW
4.90 kW
COP Tj = Tbiv
2.55
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.50 kW
4.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.96
1.53
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.50 kW
2.00 kW
Annual energy consumption Qhe
3483 kWh
4516 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.90
4.90
COP Tj = -15°C (if TOL<-20°C)
2.55
2.01
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
142 %
Prated
5.00 kW
5.00 kW
SCOP
5.06
3.63
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.40 kW
4.40 kW
COP Tj = -7°C
3.25
2.27
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.70 kW
2.70 kW
COP Tj = +2°C
5.01
3.55
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.60 kW
2.40 kW
COP Tj = +7°C
6.44
4.69
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
3.00 kW
2.90 kW
COP Tj = 12°C
8.28
6.08
Cdh Tj = +12 °C
0.960
0.970
Pdh Tj = Tbiv
5.00 kW
5.00 kW
COP Tj = Tbiv
2.82
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
5.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.82
2.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2040 kWh
2849 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
160 %
COP
4.00
Heating up time
1:14 h:min
Standby power input
28.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
112 %
COP
2.80
Heating up time
1:14 h:min
Standby power input
36.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
148 %
COP
3.61
Heating up time
1:14 h:min
Standby power input
33.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.00 kW
5.00 kW
El input
0.99 kW
1.63 kW
COP
5.05
3.07
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.55 kW
1.00 kW
Cooling capacity
5.00
5.00
EER
3.23
5.00
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.00 kW
5.00 kW
SEER
5.14
7.06
Pdc Tj = 35°C
5.00 kW
5.00 kW
EER Tj = 35°C
3.23
5.00
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
3.68 kW
3.68 kW
EER Tj = 30°C
4.37
6.08
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
2.37 kW
2.86 kW
EER Tj = 25°C
6.22
8.76
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
2.29 kW
2.77 kW
EER Tj = 20°C
6.89
9.37
Cdc Tj = 20 °C
0.990
0.990
Poff
9 W
9 W
PTO
2 W
2 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
340 kWh
248 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
237 %
168 %
Prated
5.00 kW
5.00 kW
SCOP
6.00
4.27
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.00 kW
5.00 kW
COP Tj = +2°C
3.52
2.34
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.20 kW
3.20 kW
COP Tj = +7°C
5.71
3.72
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
3.00 kW
2.80 kW
COP Tj = 12°C
7.12
5.49
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
5.00 kW
5.00 kW
COP Tj = Tbiv
3.52
2.34
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
5.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.52
2.34
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1113 kWh
1565 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
128 %
Prated
6.00 kW
6.00 kW
SCOP
4.25
3.28
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.60 kW
3.60 kW
COP Tj = -7°C
3.53
2.66
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.20 kW
2.20 kW
COP Tj = +2°C
5.20
3.97
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
2.60 kW
2.50 kW
COP Tj = +7°C
6.59
5.25
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
3.00 kW
2.90 kW
COP Tj = 12°C
8.03
6.61
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
4.90 kW
4.90 kW
COP Tj = Tbiv
2.55
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.50 kW
4.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.96
1.53
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.50 kW
2.00 kW
Annual energy consumption Qhe
3483 kWh
4516 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.90
4.90
COP Tj = -15°C (if TOL<-20°C)
2.55
2.01
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
142 %
Prated
5.00 kW
5.00 kW
SCOP
5.06
3.63
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.40 kW
4.40 kW
COP Tj = -7°C
3.25
2.27
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.70 kW
2.70 kW
COP Tj = +2°C
5.01
3.55
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.60 kW
2.40 kW
COP Tj = +7°C
6.44
4.69
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
3.00 kW
2.90 kW
COP Tj = 12°C
8.28
6.08
Cdh Tj = +12 °C
0.960
0.970
Pdh Tj = Tbiv
5.00 kW
5.00 kW
COP Tj = Tbiv
2.82
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
5.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.82
2.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2040 kWh
2849 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
160 %
COP
4.00
Heating up time
1:14 h:min
Standby power input
28.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
112 %
COP
2.80
Heating up time
1:14 h:min
Standby power input
36.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
148 %
COP
3.61
Heating up time
1:14 h:min
Standby power input
33.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.00 kW
5.00 kW
El input
0.99 kW
1.63 kW
COP
5.05
3.07
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.55 kW
1.00 kW
Cooling capacity
5.00
5.00
EER
3.23
5.00
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.00 kW
5.00 kW
SEER
5.14
7.06
Pdc Tj = 35°C
5.00 kW
5.00 kW
EER Tj = 35°C
3.23
5.00
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
3.68 kW
3.68 kW
EER Tj = 30°C
4.37
6.08
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
2.37 kW
2.86 kW
EER Tj = 25°C
6.22
8.76
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
2.29 kW
2.77 kW
EER Tj = 20°C
6.89
9.37
Cdc Tj = 20 °C
0.990
0.990
Poff
9 W
9 W
PTO
2 W
2 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
340 kWh
248 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
237 %
168 %
Prated
5.00 kW
5.00 kW
SCOP
6.00
4.27
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.00 kW
5.00 kW
COP Tj = +2°C
3.52
2.34
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.20 kW
3.20 kW
COP Tj = +7°C
5.71
3.72
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
3.00 kW
2.80 kW
COP Tj = 12°C
7.12
5.49
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
5.00 kW
5.00 kW
COP Tj = Tbiv
3.52
2.34
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
5.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.52
2.34
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1113 kWh
1565 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
128 %
Prated
6.00 kW
6.00 kW
SCOP
4.25
3.28
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.60 kW
3.60 kW
COP Tj = -7°C
3.53
2.66
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.20 kW
2.20 kW
COP Tj = +2°C
5.20
3.97
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
2.60 kW
2.50 kW
COP Tj = +7°C
6.59
5.25
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
3.00 kW
2.90 kW
COP Tj = 12°C
8.03
6.61
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
4.90 kW
4.90 kW
COP Tj = Tbiv
2.55
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.50 kW
4.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.96
1.53
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.50 kW
2.00 kW
Annual energy consumption Qhe
3483 kWh
4516 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.90
4.90
COP Tj = -15°C (if TOL<-20°C)
2.55
2.01
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
142 %
Prated
5.00 kW
5.00 kW
SCOP
5.06
3.63
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.40 kW
4.40 kW
COP Tj = -7°C
3.25
2.27
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.70 kW
2.70 kW
COP Tj = +2°C
5.01
3.55
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.60 kW
2.40 kW
COP Tj = +7°C
6.44
4.69
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
3.00 kW
2.90 kW
COP Tj = 12°C
8.28
6.08
Cdh Tj = +12 °C
0.960
0.970
Pdh Tj = Tbiv
5.00 kW
5.00 kW
COP Tj = Tbiv
2.82
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
5.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.82
2.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2040 kWh
2849 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
160 %
COP
4.00
Heating up time
1:14 h:min
Standby power input
28.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
112 %
COP
2.80
Heating up time
1:14 h:min
Standby power input
36.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
148 %
COP
3.61
Heating up time
1:14 h:min
Standby power input
33.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.00 kW
5.00 kW
El input
0.99 kW
1.63 kW
COP
5.05
3.07
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.55 kW
1.00 kW
Cooling capacity
5.00
5.00
EER
3.23
5.00
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.00 kW
5.00 kW
SEER
5.14
7.06
Pdc Tj = 35°C
5.00 kW
5.00 kW
EER Tj = 35°C
3.23
5.00
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
3.68 kW
3.68 kW
EER Tj = 30°C
4.37
6.08
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
2.37 kW
2.86 kW
EER Tj = 25°C
6.22
8.76
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
2.29 kW
2.77 kW
EER Tj = 20°C
6.89
9.37
Cdc Tj = 20 °C
0.990
0.990
Poff
9 W
9 W
PTO
2 W
2 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
340 kWh
248 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
237 %
168 %
Prated
5.00 kW
5.00 kW
SCOP
6.00
4.27
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.00 kW
5.00 kW
COP Tj = +2°C
3.52
2.34
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.20 kW
3.20 kW
COP Tj = +7°C
5.71
3.72
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
3.00 kW
2.80 kW
COP Tj = 12°C
7.12
5.49
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
5.00 kW
5.00 kW
COP Tj = Tbiv
3.52
2.34
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
5.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.52
2.34
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1113 kWh
1565 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
128 %
Prated
6.00 kW
6.00 kW
SCOP
4.25
3.28
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.60 kW
3.60 kW
COP Tj = -7°C
3.53
2.66
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.20 kW
2.20 kW
COP Tj = +2°C
5.20
3.97
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
2.60 kW
2.50 kW
COP Tj = +7°C
6.59
5.25
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
3.00 kW
2.90 kW
COP Tj = 12°C
8.03
6.61
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
4.90 kW
4.90 kW
COP Tj = Tbiv
2.55
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.50 kW
4.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.96
1.53
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.50 kW
2.00 kW
Annual energy consumption Qhe
3483 kWh
4516 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.90
4.90
COP Tj = -15°C (if TOL<-20°C)
2.55
2.01
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
142 %
Prated
5.00 kW
5.00 kW
SCOP
5.06
3.63
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.40 kW
4.40 kW
COP Tj = -7°C
3.25
2.27
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.70 kW
2.70 kW
COP Tj = +2°C
5.01
3.55
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.60 kW
2.40 kW
COP Tj = +7°C
6.44
4.69
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
3.00 kW
2.90 kW
COP Tj = 12°C
8.28
6.08
Cdh Tj = +12 °C
0.960
0.970
Pdh Tj = Tbiv
5.00 kW
5.00 kW
COP Tj = Tbiv
2.82
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
5.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.82
2.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2040 kWh
2849 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
160 %
COP
4.00
Heating up time
1:14 h:min
Standby power input
28.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
112 %
COP
2.80
Heating up time
1:14 h:min
Standby power input
36.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
148 %
COP
3.61
Heating up time
1:14 h:min
Standby power input
33.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.00 kW
5.00 kW
El input
0.99 kW
1.63 kW
COP
5.05
3.07
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.55 kW
1.00 kW
Cooling capacity
5.00
5.00
EER
3.23
5.00
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.00 kW
5.00 kW
SEER
5.14
7.06
Pdc Tj = 35°C
5.00 kW
5.00 kW
EER Tj = 35°C
3.23
5.00
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
3.68 kW
3.68 kW
EER Tj = 30°C
4.37
6.08
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
2.37 kW
2.86 kW
EER Tj = 25°C
6.22
8.76
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
2.29 kW
2.77 kW
EER Tj = 20°C
6.89
9.37
Cdc Tj = 20 °C
0.990
0.990
Poff
9 W
9 W
PTO
2 W
2 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
340 kWh
248 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
237 %
168 %
Prated
5.00 kW
5.00 kW
SCOP
6.00
4.27
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.00 kW
5.00 kW
COP Tj = +2°C
3.52
2.34
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.20 kW
3.20 kW
COP Tj = +7°C
5.71
3.72
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
3.00 kW
2.80 kW
COP Tj = 12°C
7.12
5.49
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
5.00 kW
5.00 kW
COP Tj = Tbiv
3.52
2.34
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
5.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.52
2.34
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1113 kWh
1565 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
128 %
Prated
6.00 kW
6.00 kW
SCOP
4.25
3.28
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.60 kW
3.60 kW
COP Tj = -7°C
3.53
2.66
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.20 kW
2.20 kW
COP Tj = +2°C
5.20
3.97
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
2.60 kW
2.50 kW
COP Tj = +7°C
6.59
5.25
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
3.00 kW
2.90 kW
COP Tj = 12°C
8.03
6.61
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
4.90 kW
4.90 kW
COP Tj = Tbiv
2.55
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.50 kW
4.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.96
1.53
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.50 kW
2.00 kW
Annual energy consumption Qhe
3483 kWh
4516 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.90
4.90
COP Tj = -15°C (if TOL<-20°C)
2.55
2.01
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
142 %
Prated
5.00 kW
5.00 kW
SCOP
5.06
3.63
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.40 kW
4.40 kW
COP Tj = -7°C
3.25
2.27
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.70 kW
2.70 kW
COP Tj = +2°C
5.01
3.55
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.60 kW
2.40 kW
COP Tj = +7°C
6.44
4.69
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
3.00 kW
2.90 kW
COP Tj = 12°C
8.28
6.08
Cdh Tj = +12 °C
0.960
0.970
Pdh Tj = Tbiv
5.00 kW
5.00 kW
COP Tj = Tbiv
2.82
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
5.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.82
2.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2040 kWh
2849 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
160 %
COP
4.00
Heating up time
1:14 h:min
Standby power input
28.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
112 %
COP
2.80
Heating up time
1:14 h:min
Standby power input
36.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
148 %
COP
3.61
Heating up time
1:14 h:min
Standby power input
33.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.00 kW
5.00 kW
El input
0.99 kW
1.63 kW
COP
5.05
3.07
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.55 kW
1.00 kW
Cooling capacity
5.00
5.00
EER
3.23
5.00
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.00 kW
5.00 kW
SEER
5.14
7.06
Pdc Tj = 35°C
5.00 kW
5.00 kW
EER Tj = 35°C
3.23
5.00
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
3.68 kW
3.68 kW
EER Tj = 30°C
4.37
6.08
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
2.37 kW
2.86 kW
EER Tj = 25°C
6.22
8.76
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
2.29 kW
2.77 kW
EER Tj = 20°C
6.89
9.37
Cdc Tj = 20 °C
0.990
0.990
Poff
9 W
9 W
PTO
2 W
2 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
340 kWh
248 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
237 %
168 %
Prated
5.00 kW
5.00 kW
SCOP
6.00
4.27
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.00 kW
5.00 kW
COP Tj = +2°C
3.52
2.34
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.20 kW
3.20 kW
COP Tj = +7°C
5.71
3.72
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
3.00 kW
2.80 kW
COP Tj = 12°C
7.12
5.49
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
5.00 kW
5.00 kW
COP Tj = Tbiv
3.52
2.34
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
5.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.52
2.34
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1113 kWh
1565 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
128 %
Prated
6.00 kW
6.00 kW
SCOP
4.25
3.28
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.60 kW
3.60 kW
COP Tj = -7°C
3.53
2.66
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.20 kW
2.20 kW
COP Tj = +2°C
5.20
3.97
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
2.60 kW
2.50 kW
COP Tj = +7°C
6.59
5.25
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
3.00 kW
2.90 kW
COP Tj = 12°C
8.03
6.61
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
4.90 kW
4.90 kW
COP Tj = Tbiv
2.55
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.50 kW
4.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.96
1.53
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.50 kW
2.00 kW
Annual energy consumption Qhe
3483 kWh
4516 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.90
4.90
COP Tj = -15°C (if TOL<-20°C)
2.55
2.01
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
142 %
Prated
5.00 kW
5.00 kW
SCOP
5.06
3.63
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.40 kW
4.40 kW
COP Tj = -7°C
3.25
2.27
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.70 kW
2.70 kW
COP Tj = +2°C
5.01
3.55
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.60 kW
2.40 kW
COP Tj = +7°C
6.44
4.69
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
3.00 kW
2.90 kW
COP Tj = 12°C
8.28
6.08
Cdh Tj = +12 °C
0.960
0.970
Pdh Tj = Tbiv
5.00 kW
5.00 kW
COP Tj = Tbiv
2.82
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
5.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.82
2.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2040 kWh
2849 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.00 kW
5.00 kW
El input
0.99 kW
1.63 kW
COP
5.05
3.07
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.55 kW
1.00 kW
Cooling capacity
5.00
5.00
EER
3.23
5.00
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.00 kW
5.00 kW
SEER
5.14
7.06
Pdc Tj = 35°C
5.00 kW
5.00 kW
EER Tj = 35°C
3.23
5.00
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
3.68 kW
3.68 kW
EER Tj = 30°C
4.37
6.08
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
2.37 kW
2.86 kW
EER Tj = 25°C
6.22
8.76
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
2.29 kW
2.77 kW
EER Tj = 20°C
6.89
9.37
Cdc Tj = 20 °C
0.990
0.990
Poff
9 W
9 W
PTO
2 W
2 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
340 kWh
248 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
237 %
168 %
Prated
5.00 kW
5.00 kW
SCOP
6.00
4.27
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.00 kW
5.00 kW
COP Tj = +2°C
3.52
2.34
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.20 kW
3.20 kW
COP Tj = +7°C
5.71
3.72
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
3.00 kW
2.80 kW
COP Tj = 12°C
7.12
5.49
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
5.00 kW
5.00 kW
COP Tj = Tbiv
3.52
2.34
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
5.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.52
2.34
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1113 kWh
1565 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
128 %
Prated
6.00 kW
6.00 kW
SCOP
4.25
3.28
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.60 kW
3.60 kW
COP Tj = -7°C
3.53
2.66
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.20 kW
2.20 kW
COP Tj = +2°C
5.20
3.97
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
2.60 kW
2.50 kW
COP Tj = +7°C
6.59
5.25
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
3.00 kW
2.90 kW
COP Tj = 12°C
8.03
6.61
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
4.90 kW
4.90 kW
COP Tj = Tbiv
2.55
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.50 kW
4.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.96
1.53
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.50 kW
2.00 kW
Annual energy consumption Qhe
3483 kWh
4516 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.90
4.90
COP Tj = -15°C (if TOL<-20°C)
2.55
2.01
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
142 %
Prated
5.00 kW
5.00 kW
SCOP
5.06
3.63
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.40 kW
4.40 kW
COP Tj = -7°C
3.25
2.27
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.70 kW
2.70 kW
COP Tj = +2°C
5.01
3.55
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.60 kW
2.40 kW
COP Tj = +7°C
6.44
4.69
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
3.00 kW
2.90 kW
COP Tj = 12°C
8.28
6.08
Cdh Tj = +12 °C
0.960
0.970
Pdh Tj = Tbiv
5.00 kW
5.00 kW
COP Tj = Tbiv
2.82
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
5.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.82
2.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2040 kWh
2849 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.00 kW
7.00 kW
El input
1.42 kW
2.35 kW
COP
4.93
2.98
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.31 kW
1.48 kW
Cooling capacity
7.00
7.00
EER
3.03
4.73
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.00 kW
7.00 kW
SEER
5.08
6.93
Pdc Tj = 35°C
7.00 kW
7.00 kW
EER Tj = 35°C
3.03
4.73
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
5.16 kW
5.16 kW
EER Tj = 30°C
4.48
6.25
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
3.32 kW
3.32 kW
EER Tj = 25°C
6.06
8.07
Cdc Tj = 25 °C
1.000
1.000
Pdc Tj = 20°C
2.71 kW
3.41 kW
EER Tj = 20°C
6.32
8.78
Cdc Tj = 20 °C
1.000
1.000
Poff
9 W
9 W
PTO
2 W
2 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
482 kWh
354 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
178 %
Prated
7.00 kW
6.00 kW
SCOP
6.31
4.52
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.00 kW
6.00 kW
COP Tj = +2°C
3.47
2.47
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
4.50 kW
3.90 kW
COP Tj = +7°C
5.95
3.90
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
3.30 kW
3.20 kW
COP Tj = 12°C
7.47
5.83
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
7.00 kW
6.00 kW
COP Tj = Tbiv
3.47
2.47
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
6.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.47
2.47
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1483 kWh
1775 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
129 %
Prated
7.00 kW
7.00 kW
SCOP
4.25
3.29
Tbiv
-17 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.20 kW
4.20 kW
COP Tj = -7°C
3.69
2.77
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.60 kW
2.60 kW
COP Tj = +2°C
4.92
3.81
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.80 kW
2.80 kW
COP Tj = +7°C
6.39
5.33
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
3.20 kW
3.30 kW
COP Tj = 12°C
7.50
6.94
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
6.10 kW
5.70 kW
COP Tj = Tbiv
2.41
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.30 kW
4.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.04
1.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.70 kW
2.30 kW
Annual energy consumption Qhe
4060 kWh
5241 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.70
5.70
COP Tj = -15°C (if TOL<-20°C)
2.64
2.09
Cdh Tj = -15 °C
0.990
1.000
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
142 %
Prated
7.00 kW
7.00 kW
SCOP
4.96
3.62
Tbiv
-10 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.20 kW
6.20 kW
COP Tj = -7°C
3.26
2.33
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
3.80 kW
3.80 kW
COP Tj = +2°C
4.83
3.49
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.90 kW
2.70 kW
COP Tj = +7°C
6.29
4.66
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
3.40 kW
3.30 kW
COP Tj = 12°C
7.92
6.37
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
7.00 kW
6.20 kW
COP Tj = Tbiv
2.83
2.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
6.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.83
2.08
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.80 kW
Annual energy consumption Qhe
2916 kWh
3991 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
160 %
COP
4.00
Heating up time
1:04 h:min
Standby power input
28.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
112 %
COP
2.80
Heating up time
1:04 h:min
Standby power input
36.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
148 %
COP
3.61
Heating up time
1:04 h:min
Standby power input
33.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.00 kW
7.00 kW
El input
1.42 kW
2.35 kW
COP
4.93
2.98
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.31 kW
1.48 kW
Cooling capacity
7.00
7.00
EER
3.03
4.73
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.00 kW
7.00 kW
SEER
5.08
6.93
Pdc Tj = 35°C
7.00 kW
7.00 kW
EER Tj = 35°C
3.03
4.73
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
5.16 kW
5.16 kW
EER Tj = 30°C
4.48
6.25
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
3.32 kW
3.32 kW
EER Tj = 25°C
6.06
8.07
Cdc Tj = 25 °C
1.000
1.000
Pdc Tj = 20°C
2.71 kW
3.41 kW
EER Tj = 20°C
6.32
8.78
Cdc Tj = 20 °C
1.000
1.000
Poff
9 W
9 W
PTO
2 W
2 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
482 kWh
354 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
178 %
Prated
7.00 kW
6.00 kW
SCOP
6.31
4.52
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.00 kW
6.00 kW
COP Tj = +2°C
3.47
2.47
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
4.50 kW
3.90 kW
COP Tj = +7°C
5.95
3.90
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
3.30 kW
3.20 kW
COP Tj = 12°C
7.47
5.83
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
7.00 kW
6.00 kW
COP Tj = Tbiv
3.47
2.47
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
6.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.47
2.47
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1483 kWh
1775 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
129 %
Prated
7.00 kW
7.00 kW
SCOP
4.25
3.29
Tbiv
-17 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.20 kW
4.20 kW
COP Tj = -7°C
3.69
2.77
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.60 kW
2.60 kW
COP Tj = +2°C
4.92
3.81
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.80 kW
2.80 kW
COP Tj = +7°C
6.39
5.33
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
3.20 kW
3.30 kW
COP Tj = 12°C
7.50
6.94
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
6.10 kW
5.70 kW
COP Tj = Tbiv
2.41
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.30 kW
4.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.04
1.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.70 kW
2.30 kW
Annual energy consumption Qhe
4060 kWh
5241 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.70
5.70
COP Tj = -15°C (if TOL<-20°C)
2.64
2.09
Cdh Tj = -15 °C
0.990
1.000
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
142 %
Prated
7.00 kW
7.00 kW
SCOP
4.96
3.62
Tbiv
-10 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.20 kW
6.20 kW
COP Tj = -7°C
3.26
2.33
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
3.80 kW
3.80 kW
COP Tj = +2°C
4.83
3.49
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.90 kW
2.70 kW
COP Tj = +7°C
6.29
4.66
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
3.40 kW
3.30 kW
COP Tj = 12°C
7.92
6.37
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
7.00 kW
6.20 kW
COP Tj = Tbiv
2.83
2.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
6.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.83
2.08
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.80 kW
Annual energy consumption Qhe
2916 kWh
3991 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
160 %
COP
4.00
Heating up time
1:04 h:min
Standby power input
28.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
112 %
COP
2.80
Heating up time
1:04 h:min
Standby power input
36.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
148 %
COP
3.61
Heating up time
1:04 h:min
Standby power input
33.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.00 kW
7.00 kW
El input
1.42 kW
2.35 kW
COP
4.93
2.98
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.31 kW
1.48 kW
Cooling capacity
7.00
7.00
EER
3.03
4.73
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.00 kW
7.00 kW
SEER
5.08
6.93
Pdc Tj = 35°C
7.00 kW
7.00 kW
EER Tj = 35°C
3.03
4.73
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
5.16 kW
5.16 kW
EER Tj = 30°C
4.48
6.25
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
3.32 kW
3.32 kW
EER Tj = 25°C
6.06
8.07
Cdc Tj = 25 °C
1.000
1.000
Pdc Tj = 20°C
2.71 kW
3.41 kW
EER Tj = 20°C
6.32
8.78
Cdc Tj = 20 °C
1.000
1.000
Poff
9 W
9 W
PTO
2 W
2 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
482 kWh
354 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
178 %
Prated
7.00 kW
6.00 kW
SCOP
6.31
4.52
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.00 kW
6.00 kW
COP Tj = +2°C
3.47
2.47
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
4.50 kW
3.90 kW
COP Tj = +7°C
5.95
3.90
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
3.30 kW
3.20 kW
COP Tj = 12°C
7.47
5.83
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
7.00 kW
6.00 kW
COP Tj = Tbiv
3.47
2.47
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
6.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.47
2.47
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1483 kWh
1775 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
129 %
Prated
7.00 kW
7.00 kW
SCOP
4.25
3.29
Tbiv
-17 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.20 kW
4.20 kW
COP Tj = -7°C
3.69
2.77
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.60 kW
2.60 kW
COP Tj = +2°C
4.92
3.81
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.80 kW
2.80 kW
COP Tj = +7°C
6.39
5.33
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
3.20 kW
3.30 kW
COP Tj = 12°C
7.50
6.94
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
6.10 kW
5.70 kW
COP Tj = Tbiv
2.41
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.30 kW
4.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.04
1.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.70 kW
2.30 kW
Annual energy consumption Qhe
4060 kWh
5241 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.70
5.70
COP Tj = -15°C (if TOL<-20°C)
2.64
2.09
Cdh Tj = -15 °C
0.990
1.000
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
142 %
Prated
7.00 kW
7.00 kW
SCOP
4.96
3.62
Tbiv
-10 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.20 kW
6.20 kW
COP Tj = -7°C
3.26
2.33
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
3.80 kW
3.80 kW
COP Tj = +2°C
4.83
3.49
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.90 kW
2.70 kW
COP Tj = +7°C
6.29
4.66
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
3.40 kW
3.30 kW
COP Tj = 12°C
7.92
6.37
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
7.00 kW
6.20 kW
COP Tj = Tbiv
2.83
2.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
6.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.83
2.08
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.80 kW
Annual energy consumption Qhe
2916 kWh
3991 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
160 %
COP
4.00
Heating up time
1:04 h:min
Standby power input
28.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
112 %
COP
2.80
Heating up time
1:04 h:min
Standby power input
36.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
148 %
COP
3.61
Heating up time
1:04 h:min
Standby power input
33.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.00 kW
7.00 kW
El input
1.42 kW
2.35 kW
COP
4.93
2.98
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.31 kW
1.48 kW
Cooling capacity
7.00
7.00
EER
3.03
4.73
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.00 kW
7.00 kW
SEER
5.08
6.93
Pdc Tj = 35°C
7.00 kW
7.00 kW
EER Tj = 35°C
3.03
4.73
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
5.16 kW
5.16 kW
EER Tj = 30°C
4.48
6.25
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
3.32 kW
3.32 kW
EER Tj = 25°C
6.06
8.07
Cdc Tj = 25 °C
1.000
1.000
Pdc Tj = 20°C
2.71 kW
3.41 kW
EER Tj = 20°C
6.32
8.78
Cdc Tj = 20 °C
1.000
1.000
Poff
9 W
9 W
PTO
2 W
2 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
482 kWh
354 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
178 %
Prated
7.00 kW
6.00 kW
SCOP
6.31
4.52
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.00 kW
6.00 kW
COP Tj = +2°C
3.47
2.47
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
4.50 kW
3.90 kW
COP Tj = +7°C
5.95
3.90
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
3.30 kW
3.20 kW
COP Tj = 12°C
7.47
5.83
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
7.00 kW
6.00 kW
COP Tj = Tbiv
3.47
2.47
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
6.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.47
2.47
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1483 kWh
1775 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
129 %
Prated
7.00 kW
7.00 kW
SCOP
4.25
3.29
Tbiv
-17 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.20 kW
4.20 kW
COP Tj = -7°C
3.69
2.77
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.60 kW
2.60 kW
COP Tj = +2°C
4.92
3.81
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.80 kW
2.80 kW
COP Tj = +7°C
6.39
5.33
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
3.20 kW
3.30 kW
COP Tj = 12°C
7.50
6.94
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
6.10 kW
5.70 kW
COP Tj = Tbiv
2.41
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.30 kW
4.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.04
1.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.70 kW
2.30 kW
Annual energy consumption Qhe
4060 kWh
5241 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.70
5.70
COP Tj = -15°C (if TOL<-20°C)
2.64
2.09
Cdh Tj = -15 °C
0.990
1.000
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
142 %
Prated
7.00 kW
7.00 kW
SCOP
4.96
3.62
Tbiv
-10 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.20 kW
6.20 kW
COP Tj = -7°C
3.26
2.33
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
3.80 kW
3.80 kW
COP Tj = +2°C
4.83
3.49
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.90 kW
2.70 kW
COP Tj = +7°C
6.29
4.66
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
3.40 kW
3.30 kW
COP Tj = 12°C
7.92
6.37
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
7.00 kW
6.20 kW
COP Tj = Tbiv
2.83
2.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
6.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.83
2.08
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.80 kW
Annual energy consumption Qhe
2916 kWh
3991 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
160 %
COP
4.00
Heating up time
1:04 h:min
Standby power input
28.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
112 %
COP
2.80
Heating up time
1:04 h:min
Standby power input
36.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
148 %
COP
3.61
Heating up time
1:04 h:min
Standby power input
33.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.00 kW
7.00 kW
El input
1.42 kW
2.35 kW
COP
4.93
2.98
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.31 kW
1.48 kW
Cooling capacity
7.00
7.00
EER
3.03
4.73
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.00 kW
7.00 kW
SEER
5.08
6.93
Pdc Tj = 35°C
7.00 kW
7.00 kW
EER Tj = 35°C
3.03
4.73
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
5.16 kW
5.16 kW
EER Tj = 30°C
4.48
6.25
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
3.32 kW
3.32 kW
EER Tj = 25°C
6.06
8.07
Cdc Tj = 25 °C
1.000
1.000
Pdc Tj = 20°C
2.71 kW
3.41 kW
EER Tj = 20°C
6.32
8.78
Cdc Tj = 20 °C
1.000
1.000
Poff
9 W
9 W
PTO
2 W
2 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
482 kWh
354 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
178 %
Prated
7.00 kW
6.00 kW
SCOP
6.31
4.52
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.00 kW
6.00 kW
COP Tj = +2°C
3.47
2.47
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
4.50 kW
3.90 kW
COP Tj = +7°C
5.95
3.90
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
3.30 kW
3.20 kW
COP Tj = 12°C
7.47
5.83
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
7.00 kW
6.00 kW
COP Tj = Tbiv
3.47
2.47
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
6.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.47
2.47
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1483 kWh
1775 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
129 %
Prated
7.00 kW
7.00 kW
SCOP
4.25
3.29
Tbiv
-17 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.20 kW
4.20 kW
COP Tj = -7°C
3.69
2.77
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.60 kW
2.60 kW
COP Tj = +2°C
4.92
3.81
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.80 kW
2.80 kW
COP Tj = +7°C
6.39
5.33
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
3.20 kW
3.30 kW
COP Tj = 12°C
7.50
6.94
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
6.10 kW
5.70 kW
COP Tj = Tbiv
2.41
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.30 kW
4.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.04
1.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.70 kW
2.30 kW
Annual energy consumption Qhe
4060 kWh
5241 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.70
5.70
COP Tj = -15°C (if TOL<-20°C)
2.64
2.09
Cdh Tj = -15 °C
0.990
1.000
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
142 %
Prated
7.00 kW
7.00 kW
SCOP
4.96
3.62
Tbiv
-10 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.20 kW
6.20 kW
COP Tj = -7°C
3.26
2.33
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
3.80 kW
3.80 kW
COP Tj = +2°C
4.83
3.49
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.90 kW
2.70 kW
COP Tj = +7°C
6.29
4.66
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
3.40 kW
3.30 kW
COP Tj = 12°C
7.92
6.37
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
7.00 kW
6.20 kW
COP Tj = Tbiv
2.83
2.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
6.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.83
2.08
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.80 kW
Annual energy consumption Qhe
2916 kWh
3991 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
160 %
COP
4.00
Heating up time
1:04 h:min
Standby power input
28.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
112 %
COP
2.80
Heating up time
1:04 h:min
Standby power input
36.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
148 %
COP
3.61
Heating up time
1:04 h:min
Standby power input
33.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.00 kW
7.00 kW
El input
1.42 kW
2.35 kW
COP
4.93
2.98
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.31 kW
1.48 kW
Cooling capacity
7.00
7.00
EER
3.03
4.73
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.00 kW
7.00 kW
SEER
5.08
6.93
Pdc Tj = 35°C
7.00 kW
7.00 kW
EER Tj = 35°C
3.03
4.73
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
5.16 kW
5.16 kW
EER Tj = 30°C
4.48
6.25
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
3.32 kW
3.32 kW
EER Tj = 25°C
6.06
8.07
Cdc Tj = 25 °C
1.000
1.000
Pdc Tj = 20°C
2.71 kW
3.41 kW
EER Tj = 20°C
6.32
8.78
Cdc Tj = 20 °C
1.000
1.000
Poff
9 W
9 W
PTO
2 W
2 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
482 kWh
354 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
178 %
Prated
7.00 kW
6.00 kW
SCOP
6.31
4.52
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.00 kW
6.00 kW
COP Tj = +2°C
3.47
2.47
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
4.50 kW
3.90 kW
COP Tj = +7°C
5.95
3.90
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
3.30 kW
3.20 kW
COP Tj = 12°C
7.47
5.83
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
7.00 kW
6.00 kW
COP Tj = Tbiv
3.47
2.47
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
6.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.47
2.47
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1483 kWh
1775 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
129 %
Prated
7.00 kW
7.00 kW
SCOP
4.25
3.29
Tbiv
-17 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.20 kW
4.20 kW
COP Tj = -7°C
3.69
2.77
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.60 kW
2.60 kW
COP Tj = +2°C
4.92
3.81
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.80 kW
2.80 kW
COP Tj = +7°C
6.39
5.33
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
3.20 kW
3.30 kW
COP Tj = 12°C
7.50
6.94
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
6.10 kW
5.70 kW
COP Tj = Tbiv
2.41
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.30 kW
4.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.04
1.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.70 kW
2.30 kW
Annual energy consumption Qhe
4060 kWh
5241 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.70
5.70
COP Tj = -15°C (if TOL<-20°C)
2.64
2.09
Cdh Tj = -15 °C
0.990
1.000
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
142 %
Prated
7.00 kW
7.00 kW
SCOP
4.96
3.62
Tbiv
-10 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.20 kW
6.20 kW
COP Tj = -7°C
3.26
2.33
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
3.80 kW
3.80 kW
COP Tj = +2°C
4.83
3.49
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.90 kW
2.70 kW
COP Tj = +7°C
6.29
4.66
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
3.40 kW
3.30 kW
COP Tj = 12°C
7.92
6.37
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
7.00 kW
6.20 kW
COP Tj = Tbiv
2.83
2.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
6.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.83
2.08
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.80 kW
Annual energy consumption Qhe
2916 kWh
3991 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
160 %
COP
4.00
Heating up time
1:04 h:min
Standby power input
28.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
112 %
COP
2.80
Heating up time
1:04 h:min
Standby power input
36.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
148 %
COP
3.61
Heating up time
1:04 h:min
Standby power input
33.0 W
Reference hot water temperature
52.9 °C
Mixed water at 40°C
251 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.00 kW
7.00 kW
El input
1.42 kW
2.35 kW
COP
4.93
2.98
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.31 kW
1.48 kW
Cooling capacity
7.00
7.00
EER
3.03
4.73
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.00 kW
7.00 kW
SEER
5.08
6.93
Pdc Tj = 35°C
7.00 kW
7.00 kW
EER Tj = 35°C
3.03
4.73
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
5.16 kW
5.16 kW
EER Tj = 30°C
4.48
6.25
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
3.32 kW
3.32 kW
EER Tj = 25°C
6.06
8.07
Cdc Tj = 25 °C
1.000
1.000
Pdc Tj = 20°C
2.71 kW
3.41 kW
EER Tj = 20°C
6.32
8.78
Cdc Tj = 20 °C
1.000
1.000
Poff
9 W
9 W
PTO
2 W
2 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
482 kWh
354 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
178 %
Prated
7.00 kW
6.00 kW
SCOP
6.31
4.52
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.00 kW
6.00 kW
COP Tj = +2°C
3.47
2.47
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
4.50 kW
3.90 kW
COP Tj = +7°C
5.95
3.90
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
3.30 kW
3.20 kW
COP Tj = 12°C
7.47
5.83
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
7.00 kW
6.00 kW
COP Tj = Tbiv
3.47
2.47
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
6.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.47
2.47
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1483 kWh
1775 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
129 %
Prated
7.00 kW
7.00 kW
SCOP
4.25
3.29
Tbiv
-17 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.20 kW
4.20 kW
COP Tj = -7°C
3.69
2.77
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.60 kW
2.60 kW
COP Tj = +2°C
4.92
3.81
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.80 kW
2.80 kW
COP Tj = +7°C
6.39
5.33
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
3.20 kW
3.30 kW
COP Tj = 12°C
7.50
6.94
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
6.10 kW
5.70 kW
COP Tj = Tbiv
2.41
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.30 kW
4.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.04
1.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.70 kW
2.30 kW
Annual energy consumption Qhe
4060 kWh
5241 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.70
5.70
COP Tj = -15°C (if TOL<-20°C)
2.64
2.09
Cdh Tj = -15 °C
0.990
1.000
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
142 %
Prated
7.00 kW
7.00 kW
SCOP
4.96
3.62
Tbiv
-10 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.20 kW
6.20 kW
COP Tj = -7°C
3.26
2.33
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
3.80 kW
3.80 kW
COP Tj = +2°C
4.83
3.49
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.90 kW
2.70 kW
COP Tj = +7°C
6.29
4.66
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
3.40 kW
3.30 kW
COP Tj = 12°C
7.92
6.37
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
7.00 kW
6.20 kW
COP Tj = Tbiv
2.83
2.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
6.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.83
2.08
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.80 kW
Annual energy consumption Qhe
2916 kWh
3991 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.00 kW
7.00 kW
El input
1.42 kW
2.35 kW
COP
4.93
2.98
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.31 kW
1.48 kW
Cooling capacity
7.00
7.00
EER
3.03
4.73
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.00 kW
7.00 kW
SEER
5.08
6.93
Pdc Tj = 35°C
7.00 kW
7.00 kW
EER Tj = 35°C
3.03
4.73
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
5.16 kW
5.16 kW
EER Tj = 30°C
4.48
6.25
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
3.32 kW
3.32 kW
EER Tj = 25°C
6.06
8.07
Cdc Tj = 25 °C
1.000
1.000
Pdc Tj = 20°C
2.71 kW
3.41 kW
EER Tj = 20°C
6.32
8.78
Cdc Tj = 20 °C
1.000
1.000
Poff
9 W
9 W
PTO
2 W
2 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
482 kWh
354 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
178 %
Prated
7.00 kW
6.00 kW
SCOP
6.31
4.52
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.00 kW
6.00 kW
COP Tj = +2°C
3.47
2.47
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
4.50 kW
3.90 kW
COP Tj = +7°C
5.95
3.90
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
3.30 kW
3.20 kW
COP Tj = 12°C
7.47
5.83
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
7.00 kW
6.00 kW
COP Tj = Tbiv
3.47
2.47
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
6.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.47
2.47
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1483 kWh
1775 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
129 %
Prated
7.00 kW
7.00 kW
SCOP
4.25
3.29
Tbiv
-17 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.20 kW
4.20 kW
COP Tj = -7°C
3.69
2.77
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.60 kW
2.60 kW
COP Tj = +2°C
4.92
3.81
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.80 kW
2.80 kW
COP Tj = +7°C
6.39
5.33
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
3.20 kW
3.30 kW
COP Tj = 12°C
7.50
6.94
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
6.10 kW
5.70 kW
COP Tj = Tbiv
2.41
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.30 kW
4.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.04
1.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.70 kW
2.30 kW
Annual energy consumption Qhe
4060 kWh
5241 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.70
5.70
COP Tj = -15°C (if TOL<-20°C)
2.64
2.09
Cdh Tj = -15 °C
0.990
1.000
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
142 %
Prated
7.00 kW
7.00 kW
SCOP
4.96
3.62
Tbiv
-10 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.20 kW
6.20 kW
COP Tj = -7°C
3.26
2.33
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
3.80 kW
3.80 kW
COP Tj = +2°C
4.83
3.49
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.90 kW
2.70 kW
COP Tj = +7°C
6.29
4.66
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
3.40 kW
3.30 kW
COP Tj = 12°C
7.92
6.37
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
7.00 kW
6.20 kW
COP Tj = Tbiv
2.83
2.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
6.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.83
2.08
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
13 W
13 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.80 kW
Annual energy consumption Qhe
2916 kWh
3991 kWh