7,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
31.01 kW
29.91 kW
El input
8.64 kW
11.22 kW
COP
3.59
2.67
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
69 dB(A)
69 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
134 %
110 %
Prated
31.00 kW
33.00 kW
SCOP
3.42
2.84
Tbiv
-5 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
23.90 kW
25.50 kW
COP Tj = -7°C
2.88
2.30
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
29.60 kW
30.50 kW
COP Tj = +2°C
3.46
2.84
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
31.30 kW
30.70 kW
COP Tj = +7°C
3.87
3.24
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
39.60 kW
38.70 kW
COP Tj = 12°C
4.78
4.05
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
25.20 kW
26.50 kW
COP Tj = Tbiv
3.03
2.43
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
22.10 kW
23.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.67
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
7 W
7 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
8.90 kW
9.10 kW
Annual energy consumption Qhe
18707 kWh
24031 kWh