Certificate holders

Subtype

TTF 12.5

Certificate Holder
tecalor GmbH
Fürstenbergerstr. 77
37603 Holzminden
Germany
Registration number
012-C700171 / issue 2
Certification Body
RISE CERT
Subtype title
TTF 12.5
Driving energy
Electricity
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R452B
Mass of Refrigerant

1,000 kg

Certification Date
22.02.2023
Testing basis
EN 14511:2018, EN 14825:2018, EN 12102:2017.
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

TTF 12.5
Configure model
Model name
TTF 12.5
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

12.42 kW

11.85 kW

El input

2.75 kW

3.93 kW

COP

4.52

3.01

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

46 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

143 %

Prated

14.67 kW

13.90 kW

SCOP

5.00

3.76

Tbiv

4 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.42 kW

11.85 kW

COP Tj = +2°C

4.52

3.03

Cdh Tj = +2 °C

0.997

0.998

Pdh Tj = +7°C

12.73 kW

11.98 kW

COP Tj = +7°C

4.90

3.50

Cdh Tj = +7 °C

0.996

0.997

Pdh Tj = 12°C

12.96 kW

12.22 kW

COP Tj = 12°C

5.31

4.22

Cdh Tj = +12 °C

0.996

0.997

Pdh Tj = Tbiv

12.57 kW

11.91 kW

COP Tj = Tbiv

4.73

3.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.42 kW

11.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.52

3.03

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.998

WTOL

65 °C

65 °C

Poff

6 W

6 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.25 kW

2.05 kW

Annual energy consumption Qhe

3922 kWh

4932 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

46 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

145 %

Prated

14.56 kW

14.18 kW

SCOP

5.09

3.83

Tbiv

-17 °C

-16 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

12.83 kW

12.02 kW

COP Tj = -7°C

5.02

3.63

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

12.95 kW

12.14 kW

COP Tj = +2°C

5.25

4.02

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

12.98 kW

12.32 kW

COP Tj = +7°C

5.40

4.39

Cdh Tj = +7 °C

0.996

0.997

Pdh Tj = 12°C

12.99 kW

12.49 kW

COP Tj = 12°C

5.44

4.70

Cdh Tj = +12 °C

0.996

0.996

Pdh Tj = Tbiv

12.65 kW

11.94 kW

COP Tj = Tbiv

4.81

3.37

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.42 kW

11.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.52

3.03

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

65 °C

65 °C

Poff

6 W

6 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.14 kW

2.33 kW

Annual energy consumption Qhe

7049 kWh

9120 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

46 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

142 %

Prated

13.51 kW

14.79 kW

SCOP

4.94

3.74

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.49 kW

11.90 kW

COP Tj = -7°C

4.64

3.22

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

12.75 kW

12.06 kW

COP Tj = +2°C

4.92

3.76

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

12.94 kW

12.17 kW

COP Tj = +7°C

5.22

4.10

Cdh Tj = +7 °C

0.996

0.997

Pdh Tj = 12°C

13.00 kW

12.40 kW

COP Tj = 12°C

5.46

4.53

Cdh Tj = +12 °C

0.996

0.997

Pdh Tj = Tbiv

12.47 kW

11.94 kW

COP Tj = Tbiv

4.59

3.38

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.42 kW

11.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.52

3.03

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

65 °C

65 °C

Poff

6 W

6 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.09 kW

2.94 kW

Annual energy consumption Qhe

5650 kWh

8167 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

16.19 kW

15.12 kW

El input

2.81 kW

4.05 kW

COP

5.76

3.73

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

242 %

185 %

Prated

17.53 kW

18.01 kW

SCOP

6.25

4.82

Tbiv

3 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

16.26 kW

15.12 kW

COP Tj = +2°C

5.78

3.73

Cdh Tj = +2 °C

0.997

0.998

Pdh Tj = +7°C

16.38 kW

15.69 kW

COP Tj = +7°C

6.12

4.44

Cdh Tj = +7 °C

0.996

0.997

Pdh Tj = 12°C

16.50 kW

16.18 kW

COP Tj = 12°C

6.58

5.50

Cdh Tj = +12 °C

0.996

0.997

Pdh Tj = Tbiv

16.28 kW

15.44 kW

COP Tj = Tbiv

5.89

4.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.26 kW

15.12 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.78

3.73

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

65 °C

65 °C

Poff

6 W

6 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.27 kW

2.89 kW

Annual energy consumption Qhe

3749 kWh

4991 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

246 %

189 %

Prated

18.25 kW

17.85 kW

SCOP

6.35

4.92

Tbiv

-18 °C

-17 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

16.44 kW

15.78 kW

COP Tj = -7°C

6.26

4.61

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

16.49 kW

16.06 kW

COP Tj = +2°C

6.51

5.19

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

16.50 kW

16.26 kW

COP Tj = +7°C

6.69

5.71

Cdh Tj = +7 °C

0.996

0.997

Pdh Tj = 12°C

16.50 kW

16.40 kW

COP Tj = 12°C

6.73

6.14

Cdh Tj = +12 °C

0.996

0.996

Pdh Tj = Tbiv

16.33 kW

15.50 kW

COP Tj = Tbiv

6.02

4.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.26 kW

15.12 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.78

3.73

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

65 °C

65 °C

Poff

6 W

6 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.99 kW

2.73 kW

Annual energy consumption Qhe

7088 kWh

8942 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

240 %

183 %

Prated

16.92 kW

18.30 kW

SCOP

6.20

4.78

Tbiv

-9 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

16.29 kW

15.38 kW

COP Tj = -7°C

5.91

4.02

Cdh Tj = -7 °C

0.997

0.998

Pdh Tj = +2°C

16.40 kW

15.88 kW

COP Tj = +2°C

6.17

4.79

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

16.49 kW

16.11 kW

COP Tj = +7°C

6.47

5.31

Cdh Tj = +7 °C

0.996

0.997

Pdh Tj = 12°C

16.50 kW

16.32 kW

COP Tj = 12°C

6.76

5.90

Cdh Tj = +12 °C

0.996

0.997

Pdh Tj = Tbiv

16.27 kW

15.48 kW

COP Tj = Tbiv

5.82

4.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.26 kW

15.12 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.78

3.73

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

65 °C

65 °C

Poff

6 W

6 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.66 kW

3.18 kW

Annual energy consumption Qhe

5640 kWh

7910 kWh