Certificate holders

Subtype

TTF\TTC 7.5

Certificate Holder
tecalor GmbH
Fürstenbergerstr. 77
37603 Holzminden
Germany
Registration number
012-C700247 / issue 1
Certification Body
RISE CERT
Subtype title
TTF\TTC 7.5
Driving energy
Electricity
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R452B
Mass of Refrigerant

0,850 kg

Certification Date
19.02.2024
Testing basis
EN 14511:2018, EN 14825:2018, EN 12102:2017.
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

TTC 7.5
Configure model
Model name
TTC 7.5
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.35 kW

6.84 kW

El input

1.59 kW

2.41 kW

COP

4.62

2.81

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

140 %

Prated

8.61 kW

8.08 kW

SCOP

5.02

3.71

Tbiv

4 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.35 kW

6.85 kW

COP Tj = +2°C

4.62

2.82

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

7.42 kW

7.03 kW

COP Tj = +7°C

4.93

3.39

Cdh Tj = +7 °C

0.995

0.997

Pdh Tj = 12°C

7.51 kW

7.26 kW

COP Tj = 12°C

5.33

4.24

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

7.38 kW

6.93 kW

COP Tj = Tbiv

4.79

3.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.35 kW

6.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.62

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.26 kW

1.23 kW

Annual energy consumption Qhe

2293 kWh

2909 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

144 %

Prated

8.25 kW

8.27 kW

SCOP

5.10

3.80

Tbiv

-18 °C

-16 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.44 kW

7.09 kW

COP Tj = -7°C

5.01

3.56

Cdh Tj = -7 °C

0.995

0.997

Pdh Tj = +2°C

7.49 kW

7.21 kW

COP Tj = +2°C

5.24

4.02

Cdh Tj = +2 °C

0.995

0.996

Pdh Tj = +7°C

7.53 kW

7.30 kW

COP Tj = +7°C

5.43

4.40

Cdh Tj = +7 °C

0.995

0.996

Pdh Tj = 12°C

7.54 kW

7.38 kW

COP Tj = 12°C

5.47

4.64

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

7.39 kW

6.96 kW

COP Tj = Tbiv

4.80

3.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.35 kW

6.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.62

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.90 kW

1.41 kW

Annual energy consumption Qhe

3989 kWh

5356 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

140 %

Prated

7.97 kW

8.62 kW

SCOP

4.96

3.70

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.36 kW

6.91 kW

COP Tj = -7°C

4.72

3.04

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

7.43 kW

7.15 kW

COP Tj = +2°C

4.95

3.73

Cdh Tj = +2 °C

0.995

0.996

Pdh Tj = +7°C

7.49 kW

7.23 kW

COP Tj = +7°C

5.22

4.12

Cdh Tj = +7 °C

0.995

0.996

Pdh Tj = 12°C

7.55 kW

7.34 kW

COP Tj = 12°C

5.50

4.52

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

7.36 kW

6.96 kW

COP Tj = Tbiv

4.68

3.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.35 kW

6.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.62

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.62 kW

1.77 kW

Annual energy consumption Qhe

3318 kWh

4812 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

9.32 kW

8.81 kW

El input

1.61 kW

2.46 kW

COP

5.78

3.59

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

246 %

181 %

Prated

10.07 kW

10.43 kW

SCOP

6.34

4.73

Tbiv

3 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.35 kW

8.81 kW

COP Tj = +2°C

5.82

3.59

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

9.41 kW

9.06 kW

COP Tj = +7°C

6.19

4.32

Cdh Tj = +7 °C

0.996

0.997

Pdh Tj = 12°C

9.52 kW

9.35 kW

COP Tj = 12°C

6.73

5.47

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

9.35 kW

8.94 kW

COP Tj = Tbiv

5.92

3.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.35 kW

8.81 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.82

3.59

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.72 kW

1.62 kW

Annual energy consumption Qhe

2122 kWh

2947 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

250 %

185 %

Prated

10.49 kW

10.69 kW

SCOP

6.46

4.84

Tbiv

-18 °C

-16 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.45 kW

9.12 kW

COP Tj = -7°C

6.36

4.53

Cdh Tj = -7 °C

0.995

0.997

Pdh Tj = +2°C

9.51 kW

9.28 kW

COP Tj = +2°C

6.65

5.15

Cdh Tj = +2 °C

0.995

0.996

Pdh Tj = +7°C

9.54 kW

9.39 kW

COP Tj = +7°C

6.87

5.70

Cdh Tj = +7 °C

0.995

0.996

Pdh Tj = 12°C

9.54 kW

9.46 kW

COP Tj = 12°C

6.92

6.15

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

9.38 kW

9.00 kW

COP Tj = Tbiv

6.07

4.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.35 kW

8.81 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.82

3.59

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.14 kW

1.88 kW

Annual energy consumption Qhe

4001 kWh

5449 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

243 %

180 %

Prated

10.13 kW

10.59 kW

SCOP

6.28

4.69

Tbiv

-8 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.35 kW

8.92 kW

COP Tj = -7°C

5.95

3.88

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

9.43 kW

9.16 kW

COP Tj = +2°C

6.27

4.70

Cdh Tj = +2 °C

0.995

0.997

Pdh Tj = +7°C

9.50 kW

9.30 kW

COP Tj = +7°C

6.62

5.26

Cdh Tj = +7 °C

0.995

0.996

Pdh Tj = 12°C

9.55 kW

9.42 kW

COP Tj = 12°C

6.96

5.89

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

9.35 kW

8.96 kW

COP Tj = Tbiv

5.90

4.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.35 kW

8.81 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.82

3.59

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.78 kW

1.78 kW

Annual energy consumption Qhe

3332 kWh

4665 kWh

TTF 7.5
Configure model
Model name
TTF 7.5
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.35 kW

6.84 kW

El input

1.59 kW

2.41 kW

COP

4.62

2.81

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

140 %

Prated

8.61 kW

8.08 kW

SCOP

5.02

3.71

Tbiv

4 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.35 kW

6.85 kW

COP Tj = +2°C

4.62

2.82

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

7.42 kW

7.03 kW

COP Tj = +7°C

4.93

3.39

Cdh Tj = +7 °C

0.995

0.997

Pdh Tj = 12°C

7.51 kW

7.26 kW

COP Tj = 12°C

5.33

4.24

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

7.38 kW

6.93 kW

COP Tj = Tbiv

4.79

3.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.35 kW

6.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.62

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.26 kW

1.23 kW

Annual energy consumption Qhe

2293 kWh

2909 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

144 %

Prated

8.25 kW

8.27 kW

SCOP

5.10

3.80

Tbiv

-18 °C

-16 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.44 kW

7.09 kW

COP Tj = -7°C

5.01

3.56

Cdh Tj = -7 °C

0.995

0.997

Pdh Tj = +2°C

7.49 kW

7.21 kW

COP Tj = +2°C

5.24

4.02

Cdh Tj = +2 °C

0.995

0.996

Pdh Tj = +7°C

7.53 kW

7.30 kW

COP Tj = +7°C

5.43

4.40

Cdh Tj = +7 °C

0.995

0.996

Pdh Tj = 12°C

7.54 kW

7.38 kW

COP Tj = 12°C

5.47

4.64

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

7.39 kW

6.96 kW

COP Tj = Tbiv

4.80

3.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.35 kW

6.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.62

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.90 kW

1.41 kW

Annual energy consumption Qhe

3989 kWh

5356 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

140 %

Prated

7.97 kW

8.62 kW

SCOP

4.96

3.70

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.36 kW

6.91 kW

COP Tj = -7°C

4.72

3.04

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

7.43 kW

7.15 kW

COP Tj = +2°C

4.95

3.73

Cdh Tj = +2 °C

0.995

0.996

Pdh Tj = +7°C

7.49 kW

7.23 kW

COP Tj = +7°C

5.22

4.12

Cdh Tj = +7 °C

0.995

0.996

Pdh Tj = 12°C

7.55 kW

7.34 kW

COP Tj = 12°C

5.50

4.52

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

7.36 kW

6.96 kW

COP Tj = Tbiv

4.68

3.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.35 kW

6.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.62

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.62 kW

1.77 kW

Annual energy consumption Qhe

3318 kWh

4812 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

9.32 kW

8.81 kW

El input

1.61 kW

2.46 kW

COP

5.78

3.59

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

246 %

181 %

Prated

10.07 kW

10.43 kW

SCOP

6.34

4.73

Tbiv

3 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.35 kW

8.81 kW

COP Tj = +2°C

5.82

3.59

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

9.41 kW

9.06 kW

COP Tj = +7°C

6.19

4.32

Cdh Tj = +7 °C

0.996

0.997

Pdh Tj = 12°C

9.52 kW

9.35 kW

COP Tj = 12°C

6.73

5.47

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

9.35 kW

8.94 kW

COP Tj = Tbiv

5.92

3.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.35 kW

8.81 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.82

3.59

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.72 kW

1.62 kW

Annual energy consumption Qhe

2122 kWh

2947 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

250 %

185 %

Prated

10.49 kW

10.69 kW

SCOP

6.46

4.84

Tbiv

-18 °C

-16 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.45 kW

9.12 kW

COP Tj = -7°C

6.36

4.53

Cdh Tj = -7 °C

0.995

0.997

Pdh Tj = +2°C

9.51 kW

9.28 kW

COP Tj = +2°C

6.65

5.15

Cdh Tj = +2 °C

0.995

0.996

Pdh Tj = +7°C

9.54 kW

9.39 kW

COP Tj = +7°C

6.87

5.70

Cdh Tj = +7 °C

0.995

0.996

Pdh Tj = 12°C

9.54 kW

9.46 kW

COP Tj = 12°C

6.92

6.15

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

9.38 kW

9.00 kW

COP Tj = Tbiv

6.07

4.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.35 kW

8.81 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.82

3.59

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.14 kW

1.88 kW

Annual energy consumption Qhe

4001 kWh

5449 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

243 %

180 %

Prated

10.13 kW

10.59 kW

SCOP

6.28

4.69

Tbiv

-8 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.35 kW

8.92 kW

COP Tj = -7°C

5.95

3.88

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

9.43 kW

9.16 kW

COP Tj = +2°C

6.27

4.70

Cdh Tj = +2 °C

0.995

0.997

Pdh Tj = +7°C

9.50 kW

9.30 kW

COP Tj = +7°C

6.62

5.26

Cdh Tj = +7 °C

0.995

0.996

Pdh Tj = 12°C

9.55 kW

9.42 kW

COP Tj = 12°C

6.96

5.89

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

9.35 kW

8.96 kW

COP Tj = Tbiv

5.90

4.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.35 kW

8.81 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.82

3.59

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

4 W

4 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.78 kW

1.78 kW

Annual energy consumption Qhe

3332 kWh

4665 kWh